Thank you for purchasing the IPM Scope CAM. This manual will
familiarize you with the features and operation of your new IPM Scope
CAM. Please read this manual thoroughly before using your
instrument. For customer support, or to place an order, call Spectrum
Technologies, Inc. at (800)248-8873 or (815) 436-4440 between 7:30
am and 5:30 p.m. CST,
www.specmeters.com
Spectrum Technologies, Inc
12360 S Industrial Dr . East
Plainfield, IL 60585
Contents
Overview 3
Keys and Indicators 4
Inserting the Battery 6
USB Connection 6
Device Setup 7
Getting the Best Image 8
Warranty 12
CE Declaration of Conformity 12
Operation 9
Caution
• Be sure to turn off the power to prevent overheating after use.
• Do not drop or strike the microscope to avoid any damage.
• When not using the microscope for extended periods of time,
please remove the battery and store the equipment in a safe place.
• The microscope is not waterproof; prevent the equipment from
immersion in water or other liquids. Do not allow liquids to enter the
interior.
• Please operate moving parts carefully to avoid damage.
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com

3
Features
• 3X to 300X magnification
• 2 inch LCD display for easy viewing, capturing
• SD Card allows the stored files editing on PC.
• 180 degree rotating Lens tube captures images at any angle.
• 6 White-light LEDs and adjustable illumination for clear images.
• Rechargeable lithium-ion battery for 5 hour continuous use.
• TV video output enables observing the image on a TV.
• CE, FCC and RoHS compliant.
Specifications
Effective pixels: 5.1M Pixels
Image Sensor: 1/2.5" CMOS
Image resolution: 3264x2448(8M). 2560x1920(5M), 2048x1536(3M).
1600x1200(2M), 1280x960(1.3M), 640x480(VGA).
LCD display: 2.0" LCD
Magnification: 3X-25X (Preview on LCD Panel)
Max. 86X (image file on LCD Panel)
3X-300X (image file on PC)
Shutter speed: 3 seconds.
Delay capture: 3 & 5 seconds.
File Format: Still image: JPEG
Movie:AVI
Movie length: Based on Storage capacity.
Video output: PAL / NTSC
Storage media: External: SD card up to 2 GB. Internal: 256 MB.
Power Source: Li-Battery (3.7V /1700mA)
Charge source: USB port / Adapter
Charge current: USB port 300 mA, Adapter 500mA.
Charge time: 4 hours (using adapter).
Operating tine: Standby 7 hours, Operating 5 hours
Language support: English / Traditional Chinese / Simplified Chinese
O / S: Windows XP, VISTA
Dimensions: 156.8(W) x 64.8(H) x 39.1(D) mm
Weight: 180g (without battery and SD card)
System Requirements: PC running Windows XP or VISTA, with one USB
port, and a VGA system with at least 16 bit color.
Overview
Contents
Portable Microscope Li battery USB Cable
Video Cable SD Card DC 5V/1A Adapter
Microscope Bag User manual
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com

4
Keys and Indicators
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com

5
Indicator Light
Blue: Device powered on.
Red: Device charging. Turns off when fully
charged.
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com

6
Plug the USB cable into a PC and the IPM Scope CAM and click the
power key. Two functions will appear on the LCD.
“Data Transfer” transfers data from the microscope to the PC.
“Battery Charge” recharges the microscope’s lithium battery.
USB Connection
Open the battery cover, and slide the battery pack in.
Close the cover.
The initial battery charge takes approximately 8 hours.
Inserting the Battery
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com

7
Device Setup
Click “MENU” key to enter MENU mode. Then click “Right” key to enter
Device Setup. Select the setup parameters: Format, Beep, Language,
Auto Off, System Reset, Light Frequency, Date & Time, and TV.
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com

8
1. Set the distance to the target object by adjusting the angle between
the main body and the base.
2. Adjust the angle of the lens tube to point to the target object.
Getting the Best Image
3. Adjust the lens tube angle through its 180 degree range to capture
the image at the desired angle.
4. Adjust the focus know to get a clear image.
5. Hold the IPM Scope CAM in your hand, adjust the distance, or set it
on a sturdy object to obtain the best image.
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com

9
Operation
Shooting Mode: Viewfinder Information
1. In shooting mode, click “MENU” to display menu lists.
2. Setting “Capture” parameters:
Size, Color, Quick View, Date Stamp, Grid.
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com

10
Recording Mode: Viewfinder Information
1. In recording mode, click “MENU” to display menu lists.
2. Setting “Video Output” format: Size.
Playback Mode: Viewfinder Information
1. In shooting or recording mode, click “PLAYBACK” to enter playback
mode.
1. In playback mode, click “MENU” to display menu lists.
2. Setting Playback files parameters:
Delete, Copy to Card, Slide Show, Protect, Rotation.
(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: bio@es-france.com - Site Web: www.es-france.com
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Spectrum Technologies Microscope
Manuels Microscope populaires d'autres marques

VWR
VWR VisiScope 384 Series Manuel utilisateur

Nikon
Nikon ECLIPSE E200 POL Manuel utilisateur

Leica
Leica DI C800 Manuel

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Manuel utilisateur

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Manuel utilisateur

Olympus
Olympus SZ61 Manuel utilisateur