Spatech LUXE Manuel utilisateur

User Manual

PEDICURE SPA USERMANUAL
Before Operating the unit, please read this manual thoroughly and retain it for future reference
RECEIVING AND INSPECTION:
PLEASE TAKE NOTE! Thoroughly inspect each shipment immediately upon arrival.
It is important that you notify the driver and insist on a notation of the damage. Make
this notation directly on the freight company’s waybill or bill of lading. Failure to note
damage on the waybill or bill of lading may impede and/or prevent any claims that you
may have against the freight carrier.
If missing parts or damage is found. Please notify the carrier at once and request an
inspection. DO NOT DISCARD THE SHIPPING BOX. If you give the carrier a clear
receipt for goods that have been damaged in transit, you do so at your own risk and
expense.
TRADEMARK DISCLAIMER
LUXE is the registered trademarks of Spatech, Inc. Reproduction or reuse of part or all of trademarks are
expressly prohibited without written permission from Spatech, Inc. Due to limitation of the printing process,
product colors shown might look different from actual colors. Spatech will not be responsible for any misprint of
this advertisement. Spatech’s footspa specification and prices may change without prior notice. Pedicure Spas
are intended for professional used only, always follow your State Board’s sanitation and disinfectant guideline.

RECEIVING AND INSPECTION: ................................................................................................1
SAFETY PRECAUTIONS:...........................................................................................................3
PARTS
Identifying Parts for LUXE Model ................................................................................................4
INSTALLATION
Spa to Spa Recommended Clearance:.......................................................................................5
Wall Clearance:............................................................................................................................6
Manicure Tray/ Armrest / Back Rest Installation.........................................................................8
Up/Down Swinging Armrest:........................................................................................................9
Back Rest:....................................................................................................................................9
Plumbing Connections:..............................................................................................................10
Power Drain: ..............................................................................................................................10
Gravity Drain (Under Ground): ..................................................................................................12
Plumbing Flow Pattern for Power Drain: ...................................................................................12
Plumbing Flow Pattern for Gravity Drain:..................................................................................12
Hot and Cold Water Supply Lines .............................................................................................12
SPA SPECIFICATION
Electrical and Pedicure Spa Component Specifications...........................................................12
OPERATION AND CARE
Manual Operation ......................................................................................................................13
Filling ..........................................................................................................................................13
Whirlpool Starting.......................................................................................................................13
Draining......................................................................................................................................19
Auto Operation: (Upgraded Option) ..........................................................................................20
Auto-Fill Models: ........................................................................................................................21
Jet Cover Removal & Installation: .............................................................................................22
Jet Housing Removal & Installation...........................................................................................23
Massage System & Remote Controller: ....................................................................................24
Safety Requirements for Pedicure Spas ...................................................................................24
WARRANTY
SPA TECH LIMITED FACTORY WARRANTY .......................................................................……24

SAFETY PRECAUTIONS:
!
Warning
THIS PRODUCT IS FOR INDOOR USE ONLY
DISCONNECT POWER SUPPLY CORD BEFORE SERVICING
This product is to be connected to a branch circuit outlet protected by a
Class A GROUND FAULT CIRCUIT INTERRUPTER (GFCI), and the GFCI
shall be tested regularly for continued protection and correct operation. If a
Class A GFCI protected outlet is not available, DO NOT USE THIS
PRODUCT! Please contact a licensed electrician for installation of a Class
A GFCI according to local electric codes, or equivalent.
!
Warning
DO NOT USE if you are diabetic, have poor circulation, or if any area of
your feet or legs is inflamed or has an open sore. Consult your physician
before using if you have any kind of fungal infection, swelling, fracture or
persistent pain.
!
Warning
TO REDUCE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE
THIS UNIT UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME
• LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE
• UTILISER SEULEMENT A L’INTERIEUR
• COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE, AU NETTOYAGE
!
Warning
1. Excessive water temperature is dangerous and should be checked BEFORE use.
2. Maximum temperature of the water should never exceed 100 degrees F.
3. DO NOT STEP/ STAND IN FOOT BASIN.
4. Always enter and exit the Pedicure Spa slowly and carefully.
5. NEVER bring and / or operate any electrical devices into or near the Pedicure Spa.
6. Maximum load in spa chair is 250lbs (114kg).
!
Warning If a crack in the GLASS BOWL occurs, DO NOT handle unless the prop-
er attire and equipment is used. Discontinue use of the bowl until proper
equipment is replaced. You may be held accountable for any injury that
may occur. Spatech, Inc. is not liable for any injury that may occur.
STATES’ NOTICE
In the common wealth of most of the States, all pedicure spas shall be installed for Commercial usage in the
states, are required to have backflow preventer. This equipment shall be installed between the water inlets and
the spa at Salon’s cost.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Identifying Parts for Spatech®Model
14
13
6
7
8
Pedicure Whirlpool with Massage System
1. Head Rest
2. Chair Cushion with Massage
3. Armrest Cushion
4. Massage Remote Control
5. Manicure-Tray
6. Angelic Bowl
7. Calf Support
4 | User Manual Spatech
8. Sani-Drain System with discharge On/Off Knob
9. Hot/Cold Water Mixer Valve
10. Dual Function Auto-Fill & Jet On/Off Knob
11. Flex Water Filler/Spray Spout
12. Up/Down Armrest
13. Handbag (Purse) Hook
14. Tub Light
9
14
7

User Manual Spatech | 5
52”
58”
22”

MANICURE TRAY/ ARMREST / BACK REST INSTALLATION
Up/Down Swinging Armrest:
Plug-In the manicure trays and attach the purse hook. (1 Supplied)
6 | User Manual Spatech

Back Rest
1. To set backrest up: Lift up the backrest until a “Click” is heard. Make sure the lever is locked-
before operating.
2. To fold down backrest: Lift up lever handle located on the left side / bottom of Chair.
User Manual Spatech | 7

8 | User Manual Spatech

User Manual Spatech | 9