Spatech CADI Manuel utilisateur

PEDICURE SPA USERMANUAL
Before Operating the unit, please read this manual thoroughly and retain it for future reference
RECEIVING AND INSPECTION:
PLEASE TAKE NOTE! Thoroughly inspect each shipment immediately upon arrival. It is
important that you notify the driver and insist on a notation of the damage. Make
this notation directly on the freight company’s waybill or bill of lading. Failure to note
damage on the waybill or bill of lading may impede and/or prevent any claims that
you may have against the freight carrier.
If missing parts or damage is found. Please notify the carrier at once and request an
inspection. DO NOT DISCARD THE SHIPPING BOX. If you give the carrier a clear
receipt for goods that have been damaged in transit, you do so at your own risk and
expense.
TRADEMARK DISCLAIMER
CADI, BELLO, CELIO, BENILLI, MARLO, PORADA, ELO, and LUXE is the registered trademarks of
Spatech, Inc. Reproduction or reuse of part or all of trademarks are expressly prohibited without
written permission from Spatech, Inc. Due to limitation of the printing process, product colors shown
might look different from actual colors. Spatech will not be responsible for any misprint of this
advertisement. Spatech’s footspa specification and prices may change without prior notice.
Pedicure Spas are intended for professional used only, always follow your State Board’s sanitation
and disinfectant guideline.

SAFETY PRECAUTIONS:
!
Warning
THIS PRODUCT IS FOR INDOOR USE ONLY
DISCONNECT POWER SUPPLY CORD BEFORE SERVICING
This product is to be connected to a branch circuit outlet protected by a Class
A GROUND FAULT CIRCUIT INTERRUPTER (GFCI), and the GFCI shall be tested
regularly for continued protection and correct operation. If a Class A GFCI
protected outlet is not available, DO NOT USE THIS PRODUCT! Please contact a
licensed electrician for installation of a Class A GFCI according to local electric
c
od
e
s, or
e
qui
v
a
lent
!
Warning
DO NOT USE if you are diabetic, have poor circulation, or if any area of your
feet or legs is inflamed or has an open sore. Consult your physician before
using if you have any kind of fungal infection, swelling, fracture or persistent
pa
i
n.
!
Warning
TO REDUCE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE THIS UNIT
UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME
LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE
UTILISER SEULEMENT A L’INTERIEUR
COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE, AU
NETTOYAGE
!
Warning
1. Excessive water temperature is dangerous and should be checked BEFORE
use.
2. Maximum temperature of the water should never exceed 100 degrees F.
3. DO NOT STEP/ STAND IN FOOT BASIN.
4. Always enter and exit the Pedicure Spa slowly and carefully.
5. NEVER bring and / or operate any electrical devices into or near the
Pedicure Spa.
6. M
a
x
i
m
um
load in spa
c
h
a
ir is 250
l
bs (114
k
g
).
!
Warning
If a crack in the GLASS BOWL occurs, DO NOT handle unless the proper attire
and equipment is used. Discontinue use of the bowl until proper equipment is
replaced. You may be held accountable for any injury that may occur. Spatech,
Inc. is not liable for any injury that may occur.
STATES’ NOTICE
In the common wealth of most of the States, all pedicure spas shall be installed for Commercial
usage in the states, are required to have backflow preventer. This equipment shall be installed
between the water inlets and the spa at Salon’s cost.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Connect drain with power drain (pump) or gravity drain (no pump)
Using ¾” schedule 40 PVC (Power Drain) or 1 ¼” flex tube (Gravity Drain) and appropriate P-
Traps connect drain to meet local plumbing codes.
Rubber connection to the drain should be removable for easy service and should not be
permanent to prevent damages.

Plumbing Flow Pattern for Gravity Drain:
*** Extra 1 ¼” Flex-hose is supplied for fast connecting to underground 1 ½” connector
Hot and cold water supply lines
Before water line connections, please follow
below:
Determine if your spa chair is used for a new construction of a salon or a replacement spa
chair.
1. New construction: Make sure to remove any and all debris and/or dust from current hot cold
water pipes before hooking up to spa. Suggested direction to remove debris: turn on water and
drain into a bucket or container.
2. Replacement Spa: Always use new hot/cold water hoses when connecting a new spa chair
to prevent debris, such as old rubber particles, from clogging drain.
*** Vaccum Breaker
Due to Town and/or State requirement/s are varies in building code, if the Town and /or
State requires Vacuum Breaker, As the Plumber MUST provide Vacuum Breaker according
to building code requirement.




Electrical Service:
INSTALLATION
A 110V, 60Hz, 15 Amp GFCI protected grounded circuit must be used to
supply power to the pedicure spa
Water Supply:
• Observe and follow all local codes in regards to plumbing connections
• 30 to 80 PSI water pressure is needed to correctly fill the basin a correct
level
• The hot water supply temperature must not exceed 150oF (65oC);
exceeding this temperature may cause damage to your unit and injury. If
the temperature is higher than this, then please lower your water heater to
the correct and acceptable temperature
• Carefully connect the incoming water supply lines to appropriate fittings
located on the back of the pedicure spa. For hot and cold water supply
fittings below. For power drain/floor drain fittings location
• Shut-off valves are recommended
• To prevent the water supply contamination, our shower head includes a
back flow preventer (see figure 1). We also highly recommend you to install
a Reduced Pressure Back Flow (RPBP) for each hot & cold water supply line.
Please check with your local plumbing code requirements.
Spatech recommends Watts 909 RPBP for each main supply line (see figure
2). Installation must be done by a licensed plumber, and installation
procedures must comply with all state and local codes.

Connect drain with power drain (pump) or gravity drain (no pump)
Using ¾” schedule 40 PVC (Power Drain) or 1 ¼” flex tube (Gravity Drain) and appropriate P-
Traps connect drain to meet local plumbing codes.
Rubber connection to the drain should be removable for easy service and should not be
permanent to prevent damages.
WALL CLEARANCE & SPA to SPA RECOMMENDED CLEARANCE SPA
DIMENSION.

Ce manuel convient aux modèles suivants
7
Table des matières
Autres manuels Spatech Spa de pédicure