Sony RM-NS1000 Manuel utilisateur

4-160-012-02 (1)
© 2009 Sony Corporation
System Controller
RM-NS1000
First Step Guide __________ GB
ファーストステップガイド ___ JP
Guide des premiers pas ___ FR
Kurzanleitung ____________ DE
Guida introduttiva _________ IT
Guia de inicio ____________ ES
_________________ CS

2
To reduce the risk of fire or
electric shock, do not expose
this apparatus to rain or
moisture.
To avoid electrical shock, do not
open the cabinet. Refer servicing
to qualified personnel only.
WARNING
This unit has no power switch.
When installing the unit, incorporate a
readily accessible disconnect device in the
fixed wiring, or connect the power plug to
an easily accessible socket-outlet near the
unit. If a fault should occur during operation
of the unit, operate the disconnect device to
switch the power supply off, or disconnect
the power plug.
WARNING
1. Use the approved Power Cord (2-core
mains lead)/Appliance Connector/Plug
that conforms to the safety regulations of
each country if applicable.
2. Use the Power Cord (2-core mains lead)/
Appliance Connector/Plug conforming
to the proper ratings (Voltage, Ampere).
If you have questions on the use of the
above Power Cord/Appliance Connector/
Plug, please consult a qualified service
personnel.
IMPORTANT
The nameplate is located on the bottom.
For the customers in the U.S.A.
This equipment has been tested and found
to comply with the limits for a Class B
digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference in a residential
installation. This equipment generates,
uses, and can radiate radio frequency
energy and, if not installed and used in
accordance with the instructions, may cause
harmful interference to radio
communications. However, there is no
guarantee that interference will not occur in
a particular installation. If this equipment
does cause harmful interference to radio or
television reception, which can be
determined by turning the equipment off
and on, the user is encouraged to try to
correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving
antenna.
- Increase the separation between the
equipment and receiver.
- Connect the equipment into an outlet on
a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced
radio/TV technician for help.
You are cautioned that any changes or
modifications not expressly approved in
this manual could void your authority to
operate this equipment.
If you have any questions about this
product, you may call;
Sony Customer Information Service Center
1-800-222-7669 or http://www.sony.com/
WARNING
Declaration of Conformity
Trade Name :SONY
Model :RM-NS1000
Responsible party
:Sony Electronics Inc.
Address :16530 Via Esprillo, San
Diego, CA 92127 U.S.A.
Telephone Number
:858-942-2230
This device complies with part 15 of the
FCC Rules. Operation is subject to the
following two conditions: (1) this device
may not cause harmful interference, and
(2) this device must accept any interference
received, including interference that may
cause undesired operation.

3
Usage Notes
For the customers in Canada
This Class B digital apparatus complies
with Canadian ICES-003.
For the customers in Europe
The manufacturer of this product is Sony
Corporation, 1-7-1 Konan, Minato-ku,
Tokyo, Japan.
The Authorized Representative for EMC
and product safety is Sony Deutschland
GmbH, Hedelfinger Strasse 61, 70327
Stuttgart, Germany. For any service or
guarantee matters please refer to the
addresses given in separate service or
guarantee documents.
Usage Notes
About the LCD Display
The LCD panel fitted to this unit is
manufactured with high precision
technology, giving a functioning pixel ratio
of at least 99.99%. Thus a very small
proportion of pixels may be “stuck,” either
always off (black), always on (red, green, or
blue), or flashing. In addition, over a long
period of use, because of the physical
characteristics of the liquid crystal display,
such “stuck” pixels may appear
spontaneously. These problems are not a
malfunction.
GB

4Table of Contents
Table of Contents
Usage Notes ..................................... 3
Function Overview ......................... 5
Package Contents ........................... 7
Supported Systems ......................... 7
Using the CD-ROM Manual .......... 8
Preparations .............................. 8
Reading the CD-ROM
Manual ...................................... 8
Step 1 Connecting Devices ............. 9
Preparing the Devices to Use ... 9
Connecting the USB Cable ....... 9
Connecting the Devices .......... 11
Connecting a Pelco-D or -P
Protocol Camera
(for Use in Pelco Mode) ......... 12
Connecting the AC Adapter ... 13
Step 2 Turning On the Power and
Logging On to the System ............ 14
During Connection to the
NSR-1000 Series or RealShot
Manager Advanced ................. 14
I/O Port .......................................... 16
Specifications ................................ 17
Dimensions .................................... 18
Trademarks
• “IPELA” and are
trademarks of Sony Corporation.
Other products or system names appearing
in this document are trademarks or
registered trademarks of their respective
owners.
Further, the ®or ™symbols are not used in
the text.

5
Function Overview
Function Overview
The RM-NS1000 System Controller is a system controller for remotely operating various
functions of a surveillance system. Connect it to the surveillance server or the computer used
for remote operations in order to perform operations such as monitoring or searching for and
playing back recorded images.
The system controller has RM-NS1000 mode, and Pelco mode to select from in accordance
with your surveillance server, software, and cameras.
Configuration example in RM-NS1000 mode:
When using the NSR-1000 series or RealShot Manager Advanced, perform operation in
RM-NS1000 mode.
A keyboard and mouse are required when logging on to the NSR-1000 series or RealShot
Manager Advanced.
Note
Monitors
System Controller
RM-NS1000
NSR-1000 Series
Network
Surveillance camera
Windows
Computer
Install
RealShot Manager
Advanced Monitoring
software
Machine rooms Surveillance room
Monitoring and configuration via
system controller with RealShot
Manager Advanced Client.
NSRE-S200
NSRE-S200
Analog
cameras
System Controller
RM-NS1000
Keyboard
Mouse
Headphones

6Function Overview
Configuration example in Pelco mode:
When connecting a Pelco-D or -P protocol camera directly to the system controller via the
RS-485 port to perform pan, tilt, and zoom control, perform operation in Pelco mode.
Pelco-D or -P protocol camera
Monitors
System Controller
RM-NS1000
Video out Video out Video out

7
Package Contents / Supported Systems
Package Contents
Check that the following items are included in this package:
• This package may contain additional hardware and/or documentation for those options.
• Save the boxes and packing materials for future use.
Supported Systems
The system controller supports the following systems.
• Sony NSR-1000 Series Network Surveillance Server (Version 1.1 or later)
• A computer on which RealShot Manager Advanced (Version 1.1 or later), an application
software with controls compatible with this equipment, is installed
• RM-NS1000 System
Controller (1)
• AC adapter (1)
• First Step Guide (this document) (1)
• CD-ROM (User’s Guide) (1)
• Warranty booklet (1)
Notes

8Using the CD-ROM Manual
Using the CD-ROM Manual
The supplied CD-ROM includes manuals for this system controller (Japanese, English,
French, German, Italian, Spanish and Simplified Chinese versions).
The copies of these manuals are created in pdf (Portable Document Format).
Preparations
One of the following programs must be installed on your computer in order to use the
operation manuals contained on the CD-ROM disc.
• Adobe Reader Version 6.0 or higher
If Adobe Reader is not installed, you can download it from the following URL:
http://www.adobe.com/
Adobe and Adobe Reader are trademarks of Adobe Systems Incorporated in the United States
and/or other countries.
Reading the CD-ROM Manual
To read the manual on the CD-ROM, proceed as follows.
1Insert the CD-ROM disc in your CD-ROM drive.
The manuals are saved in the Manual folder.
2Select and click the manual that you want to read.
Depending on the version of Adobe Reader you are using, the file may not display
properly. If the file does not display properly, download the latest version of Adobe
Reader from the URL found in the “Preparations” section.
If you lose the CD-ROM disc or you cannot read it for some reason, you can purchase a
new CD-ROM disc. Contact your nearest Sony service representative.
Note
Note
Caution

9
Step 1 Connecting Devices
Step 1 Connecting Devices
Decide where to install the system controller and then connect the devices to be used to the
controller.
Preparing the Devices to Use
Prepare the devices to be connected to and used with the system controller according to the
application.
• USB keyboard
•USBmouse
• Headphones (can only be used with RealShot Manager Advanced)
• Microphone (can only be used with RealShot Manager Advanced)
• Pelco-D or -P protocol camera (for use in Pelco mode)
A keyboard and mouse are required when logging on to the NSR-1000 series or RealShot
Manager Advanced.
Connecting the USB Cable
Use the USB cable to connect the system controller to the computer on which NSR-1000
series or RealShot Manager Advanced is installed.
1Thread the USB cable through the groove underneath the controller in accordance with
the location that the system controller is placed.
Note
USB Cable

10 Step 1 Connecting Devices
2Connect the USB cable to the computer on which NSR-1000 series or RealShot Manager
Advanced is installed.
NSR-1000 Series
USB connectors
Windows PC
on which RealShot Manager Advanced
installed
or
Autres manuels pour RM-NS1000
1
Table des matières
Langues :
Autres manuels Sony Routeur réseau
Manuels Routeur réseau populaires d'autres marques

NETGEAR
NETGEAR FS526T - Switch Manuel utilisateur

Korenix
Korenix JetNet 5710G Series Manuel utilisateur

Automated Logic
Automated Logic ZN551 Manuel du propriétaire

Cisco
Cisco ASR 1000 Series Manuel de l'opérateur

EnGenius
EnGenius ESR-9710 Manuel utilisateur

Cisco
Cisco 805 Series Instructions d'utilisation et de sécurité