Installation
2
INSTALLATION
Static Electricity
Precautions
Before handling any internal components, discharge static electricity by
touching a grounded surface.
Wear a grounding wrist strap and stand on a grounded static protection mat.
Limit movement during installation to reduce static buildup.
Power
RM-4T
The RM-4T can be powered either from a local, UL listed, access control
(UL294) or burglar alarm (UL603), Class 2 power-limited power source with
4-hour standby capability, or from a Software House UL listed, access
control (Ul294) or burglar alarm (UL1076) panel which has 4-hour standby
capability.
Readers
Readers connected to the RM-4T can either be powered from a local UL
listed access control (UL294), or burglar alarm *Ul603), Class 2 power-
limited power source with 4-hour standby capability, or from the RM-4T.
Wall Mount Dimensions
The RM-4T must be installed in the RM-CAN and within the protected
premise in accordance with the National Electrical Code (NFPA70), and the
local authorities having jurisdiction.
Table 2: Enclosure (Wall Mount Dimensions)
Item Dimension/Location
Weight 2.5 lbs (1.2 KG)
Height 7 in. (17.78 cm)
Width 8 in. (20.32 cm)
Depth 3 1/4 in. (8.255 cm)
Two Upper
Mounting Holes
1/4 in. (.635 cm), keyhole type
Two Bottom
Mounting Holes
Circular type
Knockouts 1/2 in. (1.27 cm.), eight
Tamper Switch for cover supervision.