
Table of contents
General notes ........................... 1
Introduction ................................ 1
Handlingnotes.............................. 1
Safetynotes................................ 1
Installation and commissioning ................. 1
General description ...................... 2
Viewsofdevice ............................. 2
Description of display and operating features ...... 3
Display functions ........................... 4
Display-topline ................................4
Display-bottomline .............................4
LEDdisplays...................................4
Statusdisplays .................................5
Error messages ............................ 6
Terminal block identification ............... 9
Functions ................................... 9
Description of relay outputs ................. 11
PU1/PU2, Pressure pumps 1 and 2 ................11
IV Input valve .................................11
FVFlushvalve ................................11
PVOutputvalve ...............................11
PR1Programmablefunctionoutput1...............13
PR2 Programmablefunctionoutput2 .............. 13
AL Fault message output ("Alarm") .................13
Impulse/Meteringoutput ......................... 13
Description of signal inputs ................. 14
MPMotorprotection ............................ 14
HL and LL High and low level .....................14
HPHighwaterpressure .........................15
LPLowwaterpressure ..........................15
STOPSwitching-offoftheplant ...................15
COConcentratemonitoring.......................16
PROG Programmable function input ................16
CD1/CD2 Connections for conductivity electrode ...... 17
PT100 Connection for temperature sensor PT100 ..... 17
Watertemperaturemonitoring.....................18
OUT Interface output ....................... 18
Functioning ............................ 19
Switching on and power failure ................... 19
Production ................................ 19
Standby .................................. 19
Flush after production ....................... 19
Intervalflush............................... 19
Quality flush and emergency service ............ 19
Conductivity monitoring ...................... 20
Programming ........................... 21
Startmenu .................................... 21
Menu selection ................................. 21
Input ......................................... 21
Endmenu ..................................... 21
Informationmenu ............................... 21
Enter/change password ........................... 22
Flushingmode.................................. 22
Flushingduration................................ 22
Intervalflush ................................... 22
Qualityflush ................................... 22
Probe Permeate ................................ 22
LVPermeateMax. .............................. 22
LVPermeateMin. ............................... 22
Probe CD2. .................................... 23
Temperature compensation ....................... 23
LVTemperature ................................ 23
FunctionPump ................................. 24
FunctionLowwaterpressure ...................... 24
FunctionExcesspressure......................... 24
FunctionConcentrate ............................ 24
FunctionMotorprotection ......................... 24
FunctionStop .................................. 25
FunctionPROG................................. 25
Watermeter ................................... 25
Metering ...................................... 25
Function PR1 input .............................. 25
FunctionPR2output ............................. 26
0/4-20mAOUT ................................. 26
Release....................................... 26
Language ..................................... 26
Service menu ........................... 27
Manual flush ................................... 27
Autom.flush ................................... 27
Errorhistory.................................... 27
Calibration of conductivity sensor CD ................ 28
Operating hours ................................ 29
Watermeter ................................... 29
Time/Date ..................................... 29
Diagnosis ..................................... 29
Softwarestatus ................................. 29
Menu structure overview .................. 30
Technical appendix ...................... 31
Exampleofanosmosisplantlayout ............. 31
Connection example ......................... 31
Technicaldata .............................. 32