Skov DA 4200 Manuel

DA 4200 Floor Heating
System
Adapter Kit
Technical User Guide
604539 • 2023-08-31
English For other language variants of this document we refer to:
Español Para otras variantes del idioma de este documento, visite:
Français Pour les versions dans d'autres langues de ce document veuillez consulter:
http://docs.skov.com/1069

DA 4200 Floor Heating System
2 Technical User Guide
Product and Documentation Changes
SKOV A/S reserves the right to change this document and the product herein described without further notice.
In case of doubt, please contact SKOV A/S.
The date of change appears from the front and back pages.
Note
• All rights belong to SKOV A/S. No part of this manual may be reproduced in any manner whatsoever without
the expressed written permission of SKOV A/S in each case.
• All reasonable efforts have been made to ensure the accuracy of the information contained in this manual.
Should any mistakes or imprecise information occur in spite of this, SKOV A/S would appreciate being noti-
fied thereof.
• Irrespective of the above, SKOV A/S shall not accept any liability with regard to loss or damage caused or
alleged to be caused by reliance on any information contained herein.
• Copyright by SKOV A/S.

DA 4200 Floor Heating System
1 Product description ....................................................................................................................................... 4
2 Product survey ............................................................................................................................................... 5
2.1 Floor heating .............................................................................................................................. 5
2.2 Accessories................................................................................................................................ 6
3 Mounting guide............................................................................................................................................... 8
3.1 Recommended tools.................................................................................................................. 8
3.2 Mounting of sandwich screws.................................................................................................. 9
3.3 Mounting of floor heating unit ................................................................................................ 10
3.3.1 Mounting of adapter kit .............................................................................................................. 11
3.3.2 Mounting of manifold.................................................................................................................. 14
3.3.3 Adjusting the manifolds.............................................................................................................. 15
4 Installation guide.......................................................................................................................................... 16
4.1 Electrical connection............................................................................................................... 16
4.2 Settings in controller ............................................................................................................... 16
4.3 General information about circuit diagrams ......................................................................... 17
4.3.1 Power supply isolator................................................................................................................. 17
4.3.2 Letter code ................................................................................................................................. 17
4.4 Cable plan................................................................................................................................. 18
4.5 Circuit diagram......................................................................................................................... 18
5 Maintenance instructions ............................................................................................................................ 19
5.1 Cleaning.................................................................................................................................... 19
5.2 Recycling/Disposal .................................................................................................................. 19
6 Trouble shooting instructions .................................................................................................................... 20
7 Technical data .............................................................................................................................................. 21
7.1 Dimensioned sketch ................................................................................................................ 21
7.1.1 DA 4200 floor heating DN 25 .................................................................................................... 21
7.1.2 DA 4200 floor heating DN 32 .................................................................................................... 22
7.2 Flow diagram............................................................................................................................ 23
Technical User Guide

DA 4200 Floor Heating System
4 Technical User Guide
1 Product description
Floor heating systems are water-based on section level.
Floor heating unit 0-10 V can be controlled via a controller.
The heating system in the individual section typically includes some or all components mentioned below:
Floor heating
Floor heating pipe

DA 4200 Floor Heating System
Technical User Guide 5
2 Product survey
2.1 Floor heating
439378 DA 4200 floor heating unit 15-70 DN 25
Heating unit with adapter kit is used for adjustment of floor heating. Capac-
ity of the floor heating unit is 1800 l/h.
The heating unit 0-10 V for regulation of heating is mounted on a stainless
plate and includes circulation pump, 0-10 V actuator, 3-way control valve,
non-return valve, ball valve and 3 x DOL 12-100C temperature sensors.
2 x DOL 12-100C temperature sensors enable monitoring of flow tempera-
ture and return flow temperature.
1 x DOL 12-100C temperature sensor is used for adjustment of the flow
temperature.
The floor heating unit must be used together with the manifold kit 1+1 to
manifold kit 10+10.
439377 DA 4200 floor heating floor heating unit 25-125 DN 32
Heating unit with adapter kit is used for adjustment of floor heating. Capac-
ity of the floor heating unit is 4500 l/h.
The heating unit 0-10 V for regulation of heating is mounted on a stainless
plate and includes circulation pump, 0-10 V actuator, 3-way control valve,
non-return valve, ball valve and 3 x DOL 12-100C temperature sensors.
2 x DOL 12-100C temperature sensors enable monitoring of flow tempera-
ture and return flow temperature.
1 x DOL 12-100C temperature sensor is used for adjustment of the flow
temperature.
Use 1 heating unit per house/section.
The floor heating unit must be used together with the manifold kit 1+1 to
manifold kit 10+10.

DA 4200 Floor Heating System
6 Technical User Guide
439561 DA 4200 floor heating manifold kit 1+1
439562 DA 4200 floor heating manifold kit 2+2
439563 DA 4200 floor heating manifold kit 3+3
439564 DA 4200 floor heating manifold kit 4+4
439565 DA 4200 floor heating manifold kit 5+5
439566 DA 4200 floor heating manifold kit 6+6
439567 DA 4200 floor heating manifold kit 7+7
439568 DA 4200 floor heating manifold kit 8+8
439569 DA 4200 floor heating manifold kit 9+9
439570 DA 4200 floor heating manifold kit 10+10
The manifold kit with bracket is used together with the floor heating unit
mentioned above.
The figures specify how many supply flows + return flows can be con-
nected. Each floor heating circuit is equipped with supply and return flow;
e.g.,4 floor heating circuits thus require a manifold kit 4+4.
Is supplied complete with connection set and automatic air vent.
2.2 Accessories
439304 DA 4200 SmartHeat kit DN 25
DA 4200 SmartHeat kit is an add-on that includes a flow sensor and a soft-
ware extension of the controller. SmartHeat kit is used together with DA
4200 room heating/floor heating units DN 25.
After updating and mounting of a flow sensor, the controller can measure
water flow and flow and return temperatures to a house/section. Based on
these recordings, the controller and FarmOnline can calculate and record
the instantaneous heat consumption in kilowatts (kW) and the number of
used kilowatt-hours (kWh) for the current house/section.
The controller generates an alarm if the water flow is too low and if the flow
temperature is too low.
The kit includes flow sensor and USB stick with SmartHeat software.
The SmartHeat software can only be installed on controllers with software
version 8.0 or later.
439305 DA 4200 SmartHeat kit DN 32
DA 4200 SmartHeat kit is an add-on that includes a flow sensor and a soft-
ware extension of the controller. SmartHeat kit is used together with DA
4200 room heating/floor heating units DN 32.
After updating and mounting of a flow sensor, the controller can measure
water flow and flow and return temperatures to a house/section. Based on
these recordings, the controller and FarmOnline can calculate and record
the instantaneous heat consumption in kilowatts (kW) and the number of
used kilowatt-hours (kWh) for the current house/section.
The controller generates an alarm if the water flow is too low and if the flow
temperature is too low.
The kit includes flow sensor and USB stick with SmartHeat software.
The SmartHeat software can only be installed on controllers with software
version 8.0 or later.

DA 4200 Floor Heating System
Technical User Guide 7
439312 DA 4200 thermometer kit ø63 mm
The DA 4200 thermometer kit ø63 mm is used for reading the flow and re-
turn temperature in heating units that are not controlled by a BlueControl
controller.
439471 Floor h. pipe 20mmPn6 incl./oxygen b.120Mtr./rl. 95gr
439476 Floor h. pipe 20mmPn6 incl./oxygen b. 240Mtr./rl. 95gr
439491 Floor h. pipe 20mmPn6 incl./oxygen b. 480 Mtr./rl.95gr
Floor heating pipes for laying and casting in concrete floor.
439975 Tubolit pipe coil 22mm 13mm Insulation 2m
Foam insulation for insulation of floor heating pipe in areas where there is
no requirement for heating of floor/heat loss. E.g. passages or under the
sows in the farrowing sections.
439940 Bending fittings T/pex pipe 20mm
Bracket for fixing bends of the floor heating pipe.
Bending radius = 150mm.
Secures the bend in a 90° position and prevents breakage of the pipe.
439995 Flashing for floor heating – start
Protection rail for floor heating pipes above floor level.
Use one as shield of up to two circuits (up to 2+2).
439996 Flashing for floor heating - next
Is used together with 439995.
Use one per commenced two circuits, in addition to the two circuits which
are covered by the start module.

DA 4200 Floor Heating System
8 Technical User Guide
3 Mounting guide
Check that the ordered parts are present and undamaged before starting assembly. Please read through the
entire guide before starting assembly and fitting.
3.1 Recommended tools
Below is a list of tools recommended for assembly.
Topic Description
Screwdriver set
Utility knife
Marker pen
Tape measure
Hacksaw
Pipe wrench
Side cutter
Impact drill
Drill kit
Adjustable spanner
Water pump pliers
Spirit level

DA 4200 Floor Heating System
Technical User Guide 9
3.2 Mounting of sandwich screws
To ensure that the screw makes the right thickening and the best possible thread on the back, the correct hole
must be drilled first and the screwing must be done with the correct momentum depending on the thickness of
the metal in the sandwich panel.
Diameter of
screw [mm]
Thickness of metal in
sandwich panel
[mm]
Size of holes in
sandwich panel
[mm]
Tightness
torque
[Nm]
5
0.63 - 0.75 ø3.8 2.5
0.75 - 0.88 ø4.1 3.0
0.88 - 1.00 ø4.2 3.5
1.00 - 1.25 ø4.3 3.5
1.25 - 1.50 ø4.4 4.0

DA 4200 Floor Heating System
10 Technical User Guide
3.3 Mounting of floor heating unit
Use packing twine and joint paste when connecting the floor heating unit.
Floor heating pipes must be protected by the flashing for floor heating.
The installation must be carried out by a specialist and according to current national and EU regulations.
Flush supply pipes before connecting them.
Before start-up, fill up the system with water.
Distribution system/heat source
Return flow Supply flow
Return flow
House
(E) (E)
(F)
(F)
(A)
(B)
(D)
(E) (E)
(C)
(G)
Supply flow
(A) 3-way control valve
(B) Actuator 0-10 V
(C) Circulation pump
(D) Non-return valve
(E) Ball valve
(F) DOL 12-100C temperature sensor
(G) DOL 12-100C temperature sensor (control)
Mount the floor heating unit on the wall using 4
screws.
Make sure that the back plate is level and does not
tilt.