Sirius Technologies ST501 Manuel utilisateur

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 1
Model#: ST501
CO2/Temp/RH Indoor Air Quality Meter
Users Manual

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 2
TABLE OF CONTENTS
FEATURES & SPECIFICATIONS....................................................................................... 3
WHAT’S IN THE BOX ......................................................................................................... 7
START UP AND GENERAL OPERATION ......................................................................... 8
•Recording and Datalogging........................................................................................................................... 9
•LCD Display and Setups ............................................................................................................................... 11
•Parameter Setup Screen (1-7) ..................................................................................................................... 12
•CO2 Calibration- Using PC software......................................................................................................... 20
PC SOFTWARE & DRIVER INSTALLATION ................................................................... 25
USING PC SOFTWARE .................................................................................................... 43
WARRANTY ...................................................................................................................... 51

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 3
FEATURES & SPECIFICATIONS
Features
•3 Independent CO2, humidity and temperature sensors
•User operated CO2 calibration
•Datalogging- 50,000 records
•Fast USB download (50,000 records in less than 10 seconds)
•Internal backup battery to maintain date/time setting
•Power management IC to increase batter efficiency
•Easy- to-Use PC software for parameter settings and data analysis
•Internal CO2 alarm buzzer
Specifications
•CO2 sensor - GE Dual Beam Absorption Infrared™
•Temperature/Humidity sensors
•Measurement range - 0 to 5,000 ppm display
•Display Resolution - ±1 ppm
•Accuracy - ±75 ppm or 10% of reading (whichever is greater)
•Datalogging- 50,000 records

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 4
Applications
•• Building HVAC monitoring
•• Indoor air quality survey
•• Locate the presence of combustion fumes from vehicles and appliances
General
Operation Condition 32-122F(0-50C)
0-95%,RH,non-condensing
Storage Temperature -4 to 140F(-20 to 60C)
CO2 Sensor
Type Non-dispersive infra-red (NDIR)
Measurement Range 0 to 5,000 ppm
Accuracy ±75 ppm or 10% of reading (whichever is greater)
Resolution ±1 ppm
Response Time 2 seconds
Relative Humidity Sensor
Type CMOSens
Measurement Range 10%-90%
Accuracy 2.5%
Resolution 0.1%
Response Time 8 Seconds
Temperature Sensor
Type Thermistor
Measurement Range 0 to 50C
Accuracy ±0.5C from 0-50C
Resolution 0.1C
Response Time 1 seconds
Power Supply
Battery Four AA batteries
Battery Operation 24 hours
External Power Supply 6V VDC with 0.5A

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 5
ST501 Model Number
1.
Mode 4.
Down
Arrow
2.
Enter 5.
Up
Arrow
3.
Power 6.
Record
Buttons
Model # Description
ST501U CO2/Temperture/Humidity Meter
ST501DU CO2/Temperture/Humidity Meter with data recording

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 6
LCD Display
1. Warm Up 12. Meter/Foot
2. Recording 13. % PPM
3. Calibration 14. Temperature Reading
4. USB 15. Flow Rate
5. Outside- CO2 16. Time & Date
6. Setting 17. Elevation
7. Alarm 18. Humidity
8. High 19. Memory Left
9. Low 20. Battery
10. Maximum 21. CO2 Reading
11, Minimum

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 7
WHAT’S IN THE BOX
1.Main Unit 2. USB Cable 3. Installation Disk
4. 4X1.5V AA Alkaline
Battery
5. 6V DC Adaptor

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 8
START UP AND GENERAL OPERATION
Hold the Power button for 2 seconds to turn on ST501.
Wait 20 seconds until the “Warm-up” turns off.
The unit is ready to use.
ST501 Buttons
1.
Mode 4.
Down
Arrow
2.
Enter 5.
Up
Arrow
3. Power 6.
Record

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 9
Recording and Datalogging
Hold for 2 seconds to start data recording.
Sampling rate (5sec / 10sec / 1min / 5min / 10min / 30min / 1 hour)
can only be set from PC setup screen.

Sirius Technologies, Inc.
418-B Cloverleaf Dr. Baldwin Park, CA 91706
•TEL:(626)934-0100 • FAX:(626)934-0161 •E-Mail: [email protected]
Page 10
Power Saving Mode (Datalogging)
Sampling rate longer than 5 minutes (5min / 10min / 30min / 1 hour) will automatically turn
on power-saving mode. The ST501 will be in power-saving mode during the
non-samping period. One minute before the sampling time, the ST501 will turn on to
take the sample. After the sampling is done, the ST501 will turn back to power-saving
mode. While in the power-saving mode, the ST501 will not respond to any key inputs.
Hold for 2 seconds to exit the datalogging mode.
Sampling Interval Power-Saving
5 seconds
10 seconds
1 minutes
5 minutes 9
10 minutes 9
30 minutes 9
1 hour 9
Ce manuel convient aux modèles suivants
2
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur