1 0 MA47 Datum 16.06.2000 Art.Nr. 76671 Z.Nr. 8664049 Änd.Stand 201/00
Parameterdescription
Display Designation/description
"Choice"
_APU_
Display after 1 revolution: Value
by which the display increases /
decreases after 1 revolution of the
encoder. This value corresponds
eg. to the spindle pitch.
_Adl_
Display divisor: Divisor by which
thedisplayaccuracyisreducedcom-
paredto themeasuring acuracy.
Example:
Due to an odd ratio, the
measuring resolution is program-
med to 1/1000 mm. The display,
however,needsaresolutionof1/10
mm only. -> The display divisor is
programmedto100.
_Str_
Encoder pulses per revolution:
Incrementsoftheconnectedenco-
der.
_drEh_
Counting direction: Counting di-
rection of the system:
"I"
clockwiseincreasing value
"E"
counter-clockwiseincreasingvalu-
es
_Ind_
Type of index signal: Reference
markontheencoderdisk;appears
onlyonceperrevolution;fordefined
referencepointmarking.
"O"
Signal shape "O"; square signal
with positive logic
"I"
Signalshape"I":squaresignalwith
invertedlogic
_dP_
Positionsafterthe comma:
Determinationofthe decimal point
position
_oFF_
Offset value: Determination of a
correction value (offset).
_rFS_
Typeof referenceswitch: typeof
referencevaluetransmitter;caneit-
her be a mechanical contact or a
proximity switch.
"Schl"
Closing contact, which is normally
open; only active, if encoder has
indexpulse.
"oEFF"
Openingcontact,whichisnormally
closed; only active, if encoder has
indexpulse.
"hAnd"
Manual reset of the counter by ac-
tivatinginputRFS(closingfunction).
_rEF_
Referencevalue:Absolutedatum
point(referencepoint) ofthemeasu-
ringsystem.Thisvalueiseitherset
after system calibration or zeroed
by activating the external reset in-
put RFS.
rEL_F
Increm.measurementenable:
For programming section 2 (input
mode)viakey and incremen-
tal measurement can be:
"EIn"
-released
"AUS"
-blocked
rEF_F
Referencevalueinputenable:
for programming section 2 (input
mode) reference value correction
via key :
"EIn"
-released
"AUS"
-blocked
oFF_F
Offset input enable: for pro-
gramming section 2 (input mode):
offset value correction via key .
"EIn"
-released
"AUS"
-blocked
SEt_F
Resetenable:forprogrammingsec-
tion2(inputmode)releaseresetvia
key :
"EIn"
-released
"AUS"
-blocked
7. Input mode
Incrementalmeasurementfunction
Press keys +. to switch to incremental
measurementfunction.
The display is zeroed. The comma blinks.
Press keys +again, to block incremental
measurementfunctionandtorestoredisplayof
the absolute position value.
Precondition: Menu point ‘Increm. measure-
ment enable’ (rEL_F) in programming mode
must be programmed to "EIn".
Referencevaluecorrection
Presskey (for atleast 3seconds)toactivate
referencevaluecorrection.
Thedisplayshowsalternatinglythecurrentrefe-
rence value and the symbol „rEF“.
Use the arrow keys to enter a new value.