Siemens PROFINET CP 343-1 Manuel utilisateur

CP 343-
1
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
SIMATIC NET
S7-300 - Industrial Ethernet /
PROFINET
CP 343-1
Manual
Manual Part B
10/2012
C79000−G8976−C201-07
Preface
Properties / services
1
Performance data
2
Requirements for use
3
LEDs
4
Installation, connecting up
and commissioning
5
Notes on configuration and
operation
6
Service and maintenance
7
Technical specifications
8
Approvals
A
References
B

Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
Order number: C79000−G8976−C201
Ⓟ 10/2012 Technical data subject to change
Copyright © Siemens AG 2009 - 2012.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

CP 343-1
Manual, 10/2012, C79000−G8976−C201-07 3
Preface
Legend:
① LEDs
② Under the front panel:
PROFINET interface, 2 x 8-pin RJ-45 jack
③ Under the front cover:
- Socket for 24 VDC power supply
- Slider for setting the ground connector
④ Order number
⑤ Under the front panel:
printed text with MAC addresses and firmware version
⑥ X = placeholder for hardware product version
Figure 1 CP 343-1
Validity and product names
This description contains information on the following product:
CP 343−1
Order number 6GK7 343−1EX30−0XE0
Hardware product version 7
Firmware version V3.0
Communications processor for SIMATIC S7−300 / C7−300 and SINUMERIK 840D power
line

Preface
CP 343-1
4 Manual, 10/2012, C79000−G8976−C201-07
Note
Names
In this document, the term "CP" is used instead of the full product name.
The name STEP 7 is used for the configuration tool instead of the names STEP 7 V5.5
and STEP 7 Professional.
Innovations and compatibility with the predecessor product
Note
You will find the new functions of the module in the section Enhanced functions (Page 9).
Make sure that you read the information relating to enhanced functions and restrictions that
may apply in the section Module replacement / upgrading (Page 56).
Address label: Unique MAC address preset for the CP
The CP ships with a default MAC address. The MAC address is printed on the housing.
Address label: Unique MAC address for the CP
The CP is supplied with total of 3 default MAC addresses with the following assignment:
● PROFINET interface
● One MAC address for each of the 2 Ethernet ports of the PROFINET interface
The MAC addresses of the Ethernet ports are required only for detection and evaluation
of neighborhood and topology relations.
The MAC address of the PROFINET interface is printed on the housing.
If you configure a MAC address (ISO transport connections), we recommend that you use
the MAC address printed on the module for module configuration!
● This ensures that you assign a unique MAC address in the subnet!
● If you replace a module, the MAC address of the predecessor is adopted when you load
the configuration data; configured ISO transport connections remain operable.
You should also refer to the information in the section Replacing a module (Page 55).

Preface
CP 343-1
Manual, 10/2012, C79000−G8976−C201-07 5
Structure of the documentation
The documentation for this device consists of the following parts:
● Manual Part A: Configuration manual "Configuring and Commissioning S7CPs for
Industrial Ethernet", see references /1/ (Page 68).
● Manual Part B: Manual "CP 343-1" (this manual)
● Program blocks for SIMATIC NET S7 CPs - programming manual, see references /10/
(Page 70)
Contains the detailed description of the program blocks for the following services:
– Open communications services
– Access coordination with FETCH/WRITE
– Connection and system diagnostics
– Programmed connections and IP configuration
– PROFINET IO
Current manual release on the Internet
You will also find the current version of this manual on the Internet pages of Siemens
Automation Customer Support under the following entry ID:
24485272 (http://support.automation.siemens.com/WW/view/en/24485272)
CP documentation in the Manual Collection (order no. A5E00069051)
The "SIMATIC NET Manual Collection" DVD contains the device manuals and descriptions
of all SIMATIC NET products current at the time it was created. It is updated at regular
intervals.
Version History / Current Downloads for the SIMATIC NET S7 CPs
The "Version History/Current Downloads for SIMATIC NET S7 CPs" provides information on
all CPs available up to now for SIMATIC S7 (Industrial Ethernet, PROFIBUS and IE/PB
Link).
An up-to-date version of this document can be found at on the Internet under the entry ID:
9836605 (http://support.automation.siemens.com/WW/view/en/9836605)
SIMATIC NET glossary
Explanations of the specialist terms used in this documentation can be found in the SIMATIC
NET glossary.
You will find the SIMATIC NET glossary here: