SICK ReLy MULT1 Manuel utilisateur

OPERATING INSTRUCTIONS
ReLy MULT1
Safety relay

Described product
ReLy MULT1
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 8024307/2021-07-30 | SICK
Subject to change without notice

Contents
1 About this document........................................................................ 5
1.1 Purpose of this document........................................................................ 5
1.2 Scope......................................................................................................... 5
1.3 Target groups and structure of these operating instructions................ 5
1.4 Additional information.............................................................................. 6
1.5 Symbols and document conventions...................................................... 6
2 Safety information............................................................................ 7
2.1 General safety notes................................................................................ 7
2.2 Intended use............................................................................................. 7
2.3 Improper use............................................................................................. 7
2.4 Requirements for the qualification of personnel.................................... 8
3 Product description........................................................................... 9
3.1 Device overview........................................................................................ 9
3.2 Construction and function........................................................................ 9
3.3 Product characteristics............................................................................ 9
3.3.1 Interfaces................................................................................. 9
3.3.2 Compatible sensor types......................................................... 10
3.3.3 Restart interlock...................................................................... 10
3.3.4 External device monitoring...................................................... 10
3.3.5 Cross-circuit detection............................................................. 10
3.3.6 Status indicators...................................................................... 11
4 Project planning................................................................................ 12
4.1 Manufacturer of the machine.................................................................. 12
4.2 Operating entity of the machine.............................................................. 12
4.3 Design........................................................................................................ 12
4.4 Electrical integration................................................................................. 13
4.4.1 Enabling current paths............................................................ 13
4.4.2 Application diagnostic output................................................. 13
4.4.3 Restart interlock...................................................................... 14
4.4.4 External device monitoring (EDM).......................................... 14
4.4.5 Connection diagrams.............................................................. 15
4.5 Testing plan............................................................................................... 15
4.5.1 Minimum requirements for the regular thorough check....... 15
5 Mounting............................................................................................. 16
5.1 Safety......................................................................................................... 16
5.2 Mounting procedure................................................................................. 16
5.3 Disassembly.............................................................................................. 17
5.4 Module exchange...................................................................................... 17
6 Electrical installation........................................................................ 19
6.1 Device connection.................................................................................... 19
CONTENTS
8024307/2021-07-30 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 3
Subject to change without notice

7 Configuration..................................................................................... 22
7.1 DIP switch.................................................................................................. 22
7.2 Configuring sensor type........................................................................... 22
7.3 Configuring ReLy reset.............................................................................. 23
7.4 Activating configuration............................................................................ 23
7.5 Resetting the configuration...................................................................... 24
8 Commissioning.................................................................................. 25
8.1 Safety......................................................................................................... 25
8.2 Thorough check........................................................................................ 25
9 Troubleshooting................................................................................. 26
9.1 Safety......................................................................................................... 26
9.2 Status indicator (LED)............................................................................... 26
10 Decommissioning............................................................................. 27
10.1 Disposal..................................................................................................... 27
11 Technical data.................................................................................... 28
11.1 Data sheet................................................................................................. 28
11.2 Dimensional drawings.............................................................................. 33
11.3 Internal circuitry........................................................................................ 34
12 Ordering information........................................................................ 35
12.1 Ordering information for ReLy.................................................................. 35
13 Annex.................................................................................................. 36
13.1 Compliance with EU directives................................................................. 36
14 List of figures..................................................................................... 37
15 List of tables....................................................................................... 38
CONTENTS
4O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 8024307/2021-07-30 | SICK
Subject to change without notice

1 About this document
1.1 Purpose of this document
These operating instructions contain the information required during the life cycle of the
safety relay.
These operating instructions must be made available to everyone who works with the
safety relay.
1.2 Scope
Product
This document applies to the following products:
•Product code: ReLy MULT1
•“Operating instructions” type label entry: 8024300
Document identification
Document part number:
•This document: 8024307
•Available language versions of this document: 8024300
You can find the current version of all documents at www.sick.com.
1.3 Target groups and structure of these operating instructions
These operating instructions are intended for the following target groups: project devel‐
opers (planners, developers, designers), installers, electricians, safety experts (such as
CE authorized representatives, compliance officers, people who test and approve the
application), operators, and maintenance personnel.
These operating instructions are organized by the life phases of the device: project
planning, mounting, electrical installation, commissioning, operation and maintenance.
The table below shows the target groups and how – for many applications – these are
typically divided up between the manufacturer and the entity operating the machine in
which the device is to be integrated:
Area of responsibility Target group Specific chapters of these operating instruc‐
tions 1)
Manufacturer Project developers
(planners, developers,
designers)
"Project planning", page 12
"Technical data", page 28
Installers "Mounting", page 16
Electricians "Electrical installation", page 19
Safety experts "Project planning", page 12
"Commissioning", page 25
"Technical data", page 28
Operating entity Operators "Troubleshooting", page 26
Maintenance person‐
nel
"Troubleshooting", page 26
"Ordering information", page 35
1) Chapters not listed here are intended for all target groups. All target groups must follow all of the safety
and warning instructions in all chapters of the operating instructions!
In other applications, the operating organization is also the manufacturer of the equip‐
ment with the corresponding allocation of the target groups.
ABOUT THIS DOCUMENT 1
8024307/2021-07-30 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 5
Subject to change without notice

1.4 Additional information
www.sick.com
The following information is available on the Internet:
•This document in other languages
•Data sheets and application examples
•CAD data and dimensional drawings
•Certificates (e.g. EU declaration of conformity)
•Guide for Safe Machinery Six steps to a safe machine
1.5 Symbols and document conventions
The following symbols and conventions are used in this document:
Safety notes and other notes
DANGER
Indicates a situation presenting imminent danger, which will lead to death or serious
injuries if not prevented.
WARNING
Indicates a situation presenting possible danger, which may lead to death or serious
injuries if not prevented.
CAUTION
Indicates a situation presenting possible danger, which may lead to moderate or minor
injuries if not prevented.
NOTICE
Indicates a situation presenting possible danger, which may lead to property damage if
not prevented.
NOTE
Indicates useful tips and recommendations.
Instructions to action
bThe arrow denotes instructions to action.
1. The sequence of instructions for action is numbered.
2. Follow the order in which the numbered instructions are given.
✓The check mark denotes the result of an instruction.
LED symbols
These symbols indicate the status of an LED:
oThe LED is off.
ÖThe LED is flashing.
OThe LED is illuminated continuously.
1 ABOUT THIS DOCUMENT
6O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 8024307/2021-07-30 | SICK
Subject to change without notice

2 Safety information
2.1 General safety notes
DANGER
If the safety component is integrated incorrectly, the dangerous state may be ended to
late.
bPlan the integration of the safety component in accordance with the machine
requirements, see "Project planning", page 12.
DANGER
Hazard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
bPlease read this document carefully and make sure that you understand the
content fully before working with the device.
bFollow all safety notes in this document.
Improper installation or manipulation can lead to serious injuries.
2.2 Intended use
The safety relay is an evaluation unit device for switching safety-related circuits on and
off for the following sensor types:
•Electro-mechanical switch/safety switch (EMSS)
•Safety sensors with monitored semiconductor output (OSSD)
•Safety sensors with test input (SCSD)
•Safety pressure mats (SMAT)
•Antivalent mechanical safety switch (CMSS)
The safety relay complies with class A, group 1 as per EN 55011. Group 1 encom‐
passes all ISM devices in which intentionally generated and/or used conductor-bound
RF energy that is required for the inner function of the device itself occurs.
The safety relay must only be used within the limits of the prescribed and specified
technical data and operating conditions at all times.
Incorrect use, improper modification or manipulation of the safety relay will invalidate
any warranty from SICK; in addition, any responsibility and liability of SICK for damage
and secondary damage caused by this is excluded.
UL/CSA applications
If the product is being used in accordance with UL 508 or CSA C22.2 No. 14, the
following conditions must also be met:
•To protect the device’s 24-volt voltage supply, use a fuse with a maximum voltage
of 4 A and a minimum of 30 V DC in accordance with UL 248.
NOTE
The safety functions have not be evaluated by UL. Authorization is in accordance with
UL 508, general applications.
2.3 Improper use
The safety relay is not suitable for the following applications (this list is not exhaustive):
SAFETY INFORMATION 2
8024307/2021-07-30 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 7
Subject to change without notice

•At altitudes of over 4,000 m above sea level
•In explosion-hazardous areas
2.4 Requirements for the qualification of personnel
The protective device must be planned in, installed, connected, commissioned, and
serviced by qualified safety personnel only.
Project planning
For project planning, a person is considered qualified when he/she has expertise and
experience in the selection and use of protective devices on machines and is familiar
with the relevant technical rules and work safety regulations.
Mechanical mounting, electrical installation, and commissioning
For the task, a person is considered qualified when he/she has the expertise and
experience in the relevant field and is sufficiently familiar with the application of the
protective device on the machine to be able to assess whether it is in an operationally
safe state.
Operation and maintenance
For operation and maintenance, a person is considered competent when he/she has
the expertise and experience in the relevant field and is sufficiently familiar with the
application of the protective device on the machine and has been instructed by the
machine operator in its operation.
2 SAFETY INFORMATION
8O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 8024307/2021-07-30 | SICK
Subject to change without notice

3 Product description
3.1 Device overview
1
2
3
4
RELY
PWR
OUT
13
23
I1
Y1
14
24
I2
Y2
A2
S1
33
A1
34
X1 X2
Figure 1: Device overview
1Device unlocking
2LEDs
3Front connector unlocking
4Front connector
3.2 Construction and function
The safety relay ReLy MULT1 is an electrical switching device with inputs and outputs.
The safety capable inputs of the safety relay are connected to safety sensors or safety
switches.
2 safety capable inputs control the internal relays, which are used to reliably switch the
enabling current paths.
The enabling current paths close only when the two safety capable inputs close within
3 s of one another.
Actuators with positively guided contacts are connected to the enabling current paths.
3.3 Product characteristics
3.3.1 Interfaces
Inputs
•2 safety capable inputs
•Input for reset pushbutton or external device monitoring
Outputs
•3 enabling current paths (safe)
•2 application diagnostic outputs (not safe)
•2 Test outputs (not safe)
PRODUCT DESCRIPTION 3
8024307/2021-07-30 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 9
Subject to change without notice

3.3.2 Compatible sensor types
Table 1: Compatible sensor types
Sensor type Description Examples
Electro-mechanical
switch/safety switch
(EMSS)
EMSS Dual-channel equivalent elec‐
tro-mechanical switch/safety
switch with contacts and with‐
out signal processing unit
•Emergency stop push‐
button
•Safety door limit switch
Safety sensors with
monitored semicon‐
ductor output (OSSD)
OSSD Safety sensors with dual-chan‐
nel cross-circuit monitored semi-
conductor outputs
•Transponder safety
switch e.g., Sistra
•Safety light curtain e.g.,
deTec4
•Safety laser scanner
e.g., microScan3, nano‐
Scan3
Safety sensors with
test input
SCSD Safety sensors with a test input,
signal processing unit and test
output
Type 2/4 safety photoelec‐
tric sensor e.g., L41
Safety pressure mats SMAT •Safety pressure mats
•Edges and bars
Antivalent mechanical
safety switch
CMSS Dual-channel antivalent elec‐
tro-mechanical switch/safety
switch with contacts and with‐
out signal processing unit
Magnetic safety switches
e.g., RE11, RE21, RE31
Further topics
•"Configuring sensor type", page 22
3.3.3 Restart interlock
A restart interlock can be implemented with a reset pushbutton.
3.3.4 External device monitoring
Permanent external device monitoring can be implemented using external wiring.
3.3.5 Cross-circuit detection
A cross-circuit is detected on the safety inputs if the “EMSS” sensor type is configured.
Further topics
•"Configuring sensor type", page 22
3 PRODUCT DESCRIPTION
10 O P E R A T I N G I N S T R U C T I O N S | ReLy MULT1 8024307/2021-07-30 | SICK
Subject to change without notice
Autres manuels pour ReLy MULT1
1
Table des matières
Autres manuels SICK Relais

SICK
SICK ReLy EMSS3 Manuel utilisateur

SICK
SICK ReLy HAND1 Manuel utilisateur

SICK
SICK ReLy LOOP1 Manuel utilisateur

SICK
SICK ReLy HAND1 Manuel utilisateur

SICK
SICK ReLy OSSD1 Manuel utilisateur

SICK
SICK LBV 330 Manuel utilisateur

SICK
SICK ReLy TIME1 Manuel utilisateur

SICK
SICK ReLy EMSS1 Manuel utilisateur

SICK
SICK ReLy OSSD3 Manuel utilisateur

SICK
SICK ReLy OSSD4 Manuel utilisateur