5. After finishing above-mentioned settings, press “OK ”button to enter the heating mode. If the
temperature is below 100C/212F, then the display reads “LO”(low temperature).
6. If you need to adjust the settings during the heating mode, you could repeat step 2 to step 5 to do the
adjustment.
7. When the heat platen has settled into its desired temperature, press down the heat platen, then the
timer will automatically start counting down and CD-L indicator blinks. The timer will begin to sound once it
reaches 3 seconds. The warning is meant to prepare the user to release the handle once the time reaches 0
seconds. When the handle is lifted, the timer will automatically sound off.
8. Long press the digital controller for 4-5 seconds, then can enter the engineering model:
P-5: Temperature Difference Calibration Mode, calibration range is -99 to +99
P-6: Intermittent heating in advance before setting, setting range is from 1 to 20 Sec.
This function is to set the heating time and pause time after the machine enter the constant temperature
mode. The setting parameters is different according to different size of heat platen.
P-7: Constant temperature in advance before setting, setting range is from 1 to 9 degree.
This function is to set when the machine will enter the constant temperature mode. You could set a
temperature value that you want to enter to constant temperature before it reach the setting temperature.
For example, the setting temperature is 180℃and P-7 is 10℃, then when the temperature reaches 170℃,
it will enter the constant temperature mode, heating and pause in cycle to avoid overheat.
P-8: Constant temperature mode, when reach the setting temperature, the machine will stop heating for 1
seconds then will keep heating for few seconds, setting range is from 0 to 9 Sec.
P-9: Countdown mode: “No”means when the machine work, it will count down, “Yes”means when reach the
setting temperature, the machine will enter the countdown mode.