Senergy 6K Manuel utilisateur

6-15K
Ver. 01

Contents
Forward
Application Model
Intended Audience
Symbol Conventions
1 Safety Precautions
1.1 Personnel Safety
1.2 The PV Inverter Protection
1.3 Installation Safety
1.4 Electrical Connections
1.5 Operating and Commissioning
1.6 Maintenance
1.7 Additional Information
2 Overview of the Inverter
2.1 Functional Models
2.2 Network Application
2.3 Outline and Dimensions
2.4 Working Process
2.5 Working Modes
2.1.1 Function
2.1.2 Model Description
2.3.1 Dimensions
2.4.1 Basic principle Description
2.3.2 Outline
2.4.2 Circuit Diagrams
2.2.1 Grid-tied PV Power Systems
4.1 Checking the Outer Packing
4.2 Moving the inverter
4.3 Identify the PV Inverter
3 Storage
4 Installation
01
01
01
02
03
03
03
03
04
04
04
05
06
06
06
06
06
06
07
07
09
08
09
09
10
12
13
13
11
12
4.3.1 Nameplate
4.3.2 Compliance and Safety Symbols
13
14

5 Electrical Connections
5.1 Connecting Protection Ground (PGND) Cables
5.2 Connecting AC Output Cables
5.3 Connecting the PV Strings
5.4 Connecting Communications Cables
5.5 Installation Verification
5.1.1 Preparation
5.1.2 Wiring Procedures
5.4.1 Communications Mode Description
5.4.2 Connecting RS485 Communications Cables
5.4.3 Setting RS485 Communications Address
5.3.1 Preparation
5.2.1 Preparation
5.2.2 Procedure of Connecting AC Cables
6 System Operation
6.1 Powering ON the Inverter
6.2 Powering OFF the Inverter
7 User Interface
8 Maintenance
10 Disposal of the Inverter
11 Technical Specifications
8.1 Routine Maintenance
8.2 Inverter warning and exception handling
8.3 Removing the Inverter
9 Quality Guarantee
9.1 Quality Terms
9.2 Liability Waiver
4.5 Wall-mounting the Inverter
22
22
22
23
24
24
25
27
28
31
31
33
34
35
36
36
36
37
41
47
48
41
42
44
46
46
46
14
18
18
4.4.1 Determining the Installation Position
4.4.2 Installation Mode Requirements
4.4 Installation Requirements 14

1
Forward
Dear User,
Thank you so much for your choosing 6K-15K, the latest generation of grid-tied PV Strings
inverter (hereinafter referred to as the inverter) designed and developed by Senergytec.
This user manual introduces the inverter in terms of its installation, electrical connections,
operation, commissioning, maintenance, and troubleshooting. Please read through the manual
carefully before installing and using the inverter, and keep the manual well for future reference.
Grid-tied PV string inverter
6K/8K/10K
12K/15K
Application Model
This user manual is intended for photovoltaic (PV) inverter operating personnel and qualified
electrical technicians.
Intended Audience
This user manual is subject to change (specific please in kind prevail) without prior notice.
The latest version of user manual and other more information about the product are
available from http://www.senergytec.com, and/or by consulting your dealer.
Notes:

2
Indicates an imminently hazardous situation which, if not correctly
followed, will result in serious injury or death.
Indicates a potentially hazardous situation which, if not correctly
followed, could result in serious injury or death.
Indicates a potentially hazardous situation which, if not correctly
followed, could result in moderate or minor injury.
Indicates a potentially hazardous situation which, if not correctly
followed, could result in equipment failure to run, or property damage.
Calls attention to important information, best practices and tips:
supplement additional safety instructions for your better use of the
PV inverter to reduce the waste of your resource.
Refer to documentation (Remind operators to refer to the
documentation shipped with the inverter).
Symbol Conventions
Safety symbols used in this manual, which highlight potential safety risks and important safety
information, are listed as follows:
Symbol Description
WARNING
CAUTION
DANGER
NOTICE
NOTE

3
1 Safety Precautions
Before beginning your journey, please read these safety precautions in User Manual carefully.
a. The PV inverter must be installed, electronically connected, operated and maintained through
specially trained technician;
b. The qualified technician must be familiar with the safety regulations of electrical system,
working process of PV power generation system, and standards of local power grid;
c. The technician must read through this User Manual carefully and master it before any operation.
1.1 Personnel Safety
a. Do not tamper with any warning signs on the inverter enclosure because these signs contain
important information about safe operation.
b. Do not remove or damage the nameplate on the inverter’s enclosure because it contains
important product information.
c. Do not remove the anti-dismantle label on the inverter’s enclosure because it is the basis for
product warranty.
1.2 The PV Inverter Protection
a. Ensure there is no electronical connections around ports of the PV inverter before installing;
b. Adequate ventilation must be provided for inverter installation location. Mount the inverter in
vertical direction, and ensure that no object is put on the heat sink affecting the cooling. (For
details, refer to Chapter 4 Installation)
1.3 Installation Safety
As soon as receiving the PV inverter, please check if it is damaged
during its transportation. If yes, please contact your dealer immediately.
Please read the User Manual carefully before installing the PV inverter;
warranty or liability will be void from Senergy if damage is caused by
installation faults.
NOTICE
NOTICE

4
a. Input terminals of the PV inverter apply only to input terminals of PV String; do not connect
any other DC source to the input terminals.
b. Before connecting PV modules, ensure that is its voltage is within the safe range; when
exposed to any sunlight, PV modules can generate high voltage.
c. All electrical connections must meet the electrical standards of the country or region.
d. Cables used in electrical connections must be well fixed, good insulation, and with
appropriate specification.
1.4 Electrical Connections
a. Before getting the permission of electrical power sector in the country / region, the grid-tied
PV inverter cannot start generate power.
b. Follow the procedures of commissioning described in the user manual when commissioning
the PV inverter.
c. Do not touch any other parts'surface except the DC switch when the PV inverter is operating;
its partial parts will be extremely hot and can cause burns.
1.5 Operating and Commissioning
1.6 Maintenance
Before installing the inverter, check all electrical ports to ensure no
damage and no short circuit. Otherwise personal casualty and/or fire
will occur.
While the inverter operating, high voltage can lead to an electrical
shock hazard, and even cause personal casualties. Therefore,
operate the PV inverter strictly according to the safety precautions in
the user manual.
Power OFF all electrical terminals before the inverter maintenance;
strictly comply with the safety precautions in this document when
operating the inverter.
DANGER
DANGER
DANGER

5
a. For personal safety, maintenance personnel must wear appropriate personal protective
equipment (like insulation gloves and protective shoes) for the inverter maintenance.
b. Place temporary warning signs or erect fences to prevent unauthorized access to the
maintenance site.
c. Follow the procedures of maintenance stipulated in the manual strictly.
d. Check the relevant safety and performance of the inverter; rectify any faults that may
compromise the inverter security performance before restarting the inverter.
1.7 Additional Information
To avoid any other unforeseeable risk, contact Senergy immediately, if
there is any issue found during operation.
NOTICE

6
2 Overview of the Inverter
This chapter introduces the inverter and describes its functional model, network application,
appearance, dimensions, and working process etc.
2.1.1 Function
This series is a three-phase grid-tied PV string inverter (transformer less) that converts the DC
power generated by PV strings into AC power and feeds the power into power grid.
2.1.2 Model Description
Figure 2.1 shows a model number of the inverter, using 6K as an example.
6K
Power class code
Figure 2.1 Model number descriptions
2.1 Functional Models
2.2.1 Grid-tied PV Power Systems
This series inverter applies to grid-tied PV power systems for industrial/commercial rooftops,
fishing/farmers light complementary power generation systems, and large ground-based power
stations. Generally, these series inverters are used to low-voltage grid-tied PV power system,
as shown in Figure 2.2.
2.2 Network Application
The inverter is transformerless. Add an isolation transformer before
grounding the positive/ negative terminal of PV modules (like Thin
Film module) for operation.
Do not connect PV modules in parallel to several PV inverters for
operation.
WARNING
WARNING

7
2.3.1 Dimensions
Figure 2.4 shows the dimensions of the inverter as follows:
These series inverters support TN-S, TN-C, and TT power grids as shown in Figure 2.3.
2.3 Outline and Dimensions
Figure 2.2 a low-voltage grid-tied PV power system
PV strings inverter AC Distribution Unit low-voltage power grid
Figure 2.3 Power grids supported by these series inverters
Figure 2.4 The dimensions of the inverter by front & lateral views (unit: mm)
Inverter
TN-S TN-C TN-C-S TT
Inverter Inverter Inverter
385
490
185
Ce manuel convient aux modèles suivants
4
Table des matières
Autres manuels Senergy Onduleur