Selkirk DSP Manuel utilisateur

RM19896-1
SELKIRK CANADA CORPORASELKIRK CANADA CORPORA
SELKIRK CANADA CORPORASELKIRK CANADA CORPORA
SELKIRK CANADA CORPORATIONTION
TIONTION
TION
P.O. Box 526, Depot 1
Hamilton,OntarioL8L7X6
905-662-6600
Fax905-263-9308
1-800-263-9308
TollFreeFax1-866-835-9624
www.selkirkcanada.com
19/03/04
SELKIRK LLCSELKIRK LLC
SELKIRK LLCSELKIRK LLC
SELKIRK LLC
14801QuorumDrive
Dallas, Texas, USA 75240
972-560-2000
Fax972-560-2428
1-800-992-VENT(8368)
TollFreeFax1-877-393-4145
www.selkirkinc.com
®USC
PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING YOUR
INSTALLATION. FAILURE TO INSTALL THIS SYSTEM IN ACCORDANCE WITH
THESE INSTRUCTIONS WILL VOID THE CONDITIONS OF CERTIFICATION AND
THE MANUFACTURERS WARRANTY . KEEP THESE INSTRUCTIONS IN A SAFE
PLACE FOR FUTURE USE.
Tested to
*UL103HT & ULC-S641
A MAJOR CAUSE OF CHIMNEY CONNECTOR RELATED FIRES
IS FAILURE TO MAINTAIN REQUIRED CLEARANCES
(AIR SPACES) TO COMBUSTIBLE MATERIALS.
IT IS OF THE UTMOST IMPORTANCE THAT THIS
DOUBLE WALL CHIMNEY CONNECTOR BE INSTALLED
ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS
FACTORY BUILT CHIMNEY CONNECTOR
LISTED
INSTALLATION
INSTRUCTIONS
NorthlineExpress.com
http://www.northlineexpress.com
Toll-Free 1-866-667-8454

TYPES OF APPLIANCES
Your Chimney Connector is intended to connect a gas, liquid, or
solid fuel appliance normally producing flue gases of 650°C/
1200°F (Canada), 540°C/1000°F (US - to the Temperature
requirements of UL103HT) or less to a factory built or masonry
chimney.
This Chimney Connector must not be enclosed or pass through
attics, closets, floors, walls or ceilings, and must not be used in
place of an insulated chimney section.
The Minimum Clearance to combustibles (i.e.. walls, ceilings,
etc.) is 6" (152mm).
For mobile home installations follow the installation
instructions for the mobile home appliance and use the
chimney connector clearance required by the appliance.
PRE-INSTALLATIONGUIDELINES
Plan the installation of your appliance and chimney connector in
such a way that your chimney connector run is as short and
straight as possible.
By having too long and/or multiple bend installations you can
reduce system draft which can affect the operation, and/or
performance of your appliance and/or chimney system.
Ensure that you obtain any necessary building permits, and that
your installation will conform with all federal and municipal
building code requirements. Before commencing installation:
Use this chimney connector only with an appliance listed by a
recognized testing authority such as Intertek Testing Services
(Warnock Hersey), CSA, Underwriters Laboratories Inc.,
or Underwriters Laboratories of Canada.
The maximum recommended length of Double Wall Stove
Pipe should not exceed 20ft. Reduce this maximum limit
by 10% for every 90° bend or 5% for every 45° bend.
Provide sufficient slope in the horizontal run of the chimney
connector (20mm per meter, 1/4" per foot) to enable any
condensed liquid or creosote to run back toward the appliance.
Ensure that the horizontal chimney connector is securely
supported from the structure by means of metal or other non-
combustible supports at intervals not exceeding 1m (3ft).
All joints between sections of the chimney connector must be
secured with three sheet metal (supplied) screws per joints.
The black surface of the chimney connector may be touched up
with a high temperature flat black stove paint.
If you are upgrading from a single wall stove pipe to the
Double Wall Stove Pipe Chimney Connector, have your
chimney inspected by a certified wood technician or a certified
chimney sweep.
PARTS CHECK LIST
SECURING OFTHE DOUBLE WALL
STOVE PIPE (DSP)
The following is to assist you in connecting the Double Wall
Stove Pipe (DSP) to the Chimney system. There are two (2)
connecting methods. A Finishing Band (packaged with all
Telescopic and Adjustable Lengths) or it may be purchased
separately (DSP-FB). The second method is with the Universal
Chimney Adaptor.
Both methods can also be utilised on other chimney systems.
In all installations, all single wall parts of the chimney pipe
adaptor must be fully covered by the Finishing Band or the
Universal Chimney Adaptor. In order to accomplish this some
trimming may be required.
INSTALLATIONPROCEDURES
Install the appliance and chimney system according to the
installation instructions provided with them, ensuring that the
required clearances are maintained
CONTACTLOCALBUILDINGORFIREOFFICIALS
ABOUTRESTRICTIONSAND INSTALLATION
INSPECTIONINYOURAREA.
Inner Pipe with
crimped end
pointing down
into the
appliance flue
outlet
Outer Black
Pipe with
crimped end
pointing up
toward the
chimney
Theorientationof allchimneyconnectorcomponents must
be with the crimped end (outer black pipe) pointing up,
towardsthechimney(seediagrambelow).
ATTENTION!
To complete a proper Double Wall Stove Pipe installation, the
following parts may be required:
• Telescopic Length
• Adjustable Length
• Universal Chimney Adapt
• 6" Pipe Length
• 12" Pipe Length
• 24" Pipe Length
• 36" Pipe Length
• 45oElbow
• 90oElbow
• Tee Section
• Masonry Adapter
• Damper Kit
• Finishing Band
• Stove Adapter
• Oval to Round Adaptor
• Flush Stove Adaptor
* Denotes size of product 6"(152mm), 7"(178mm), 8"(203mm)
DSP*TL
DSP*AL-1
DSP*CA
DSP*P6-1
DSP*P12-1
DSP*P24-1
DSP*P36-1
DSP*E4-1
DSP*E9-1
DSP*TE-1
DSP*MA
DSP*DK-1
DSP-FB
DSP*SA-1
DSP8OTR
DSP*FSA-1
NorthlineExpress.com
http://www.northlineexpress.com
Toll-Free 1-866-667-8454

SUPERVENT
SELKIRK
STEP 2 : Pre-drill 3 evenly-spaced holes into the Universal Chimney
Adapter (CA) with a 3/32 metal drill bit. See Figure 2. These holes must
also pierce the Stove Pipe Adapter (ASE) and the Smoke Pipe Adaptor.
STEP 3 : Secure in place with 3 metal screws #6 X 1". NOTE:
Tigthen screws until head meets metal casing. Do not over tightnen
the screws such that the outer casing becomes deformed.
UNIVERSAL
CHIMNEY
ADAPTER
(CA)
SUPERVENT'S
CHIMNEY PIPE
ADAPTER
(ASE)
Pre-drill 3 holes evenly-spaced
with a metal bit. See Step 2.
ChimneySection
FIGURE 1
Beveled edge
FIGURE 2
SELKIRK'S
CHIMNEY PIPE
ADAPTER
Pre-drill 3 holes evenly-spaced
with a metal bit. See Step 2.
UNIVERSAL
CHIMNEY
ADAPTER
(CA)
Supervent/Superpro
Assembly
Telescopic
Length
Figure 2A
Supervent/Superpro Assembly
Step 4. On a Through-The-Wall Installation with a 90 degree
elbow, it may be necessary to cut the Chimney Pipe Adaptor
and /or the Finishing Band to the required width to be covered.
Ensure that the Finishing Band overlaps the crimped end of
the DSP and overlaps the bead snug to the beveled edge or to
the Basecap as per Figure 2A & 2B.
Step 1.Position theTelescopic Length to the appropriate location over
the Chimney Pipe Adaptor. Ensure that it’s final position will be cov-
ered by the Finishing Band which is only 3”wide. The Finishing Band
must overlap the crimped end of the DSP and the bead to the beveled
edge of the Chimney Pipe Adaptor or to the Basecap (see Figure 1A).
Step 2. Pre-drill 3 evenly spaced holes into the crimped end of
the DSP through the Chimney Pipe Adaptor with a 3/32 metal
drill bit. Secure in place with 3 #8 X 1/2” stainless steel sheet
metal screws (not supplied).
Step 3. Wrap the Finishing Band over the crimped end of the
DSP and the Chimney Pipe Adaptor. Ensure it is over the bead
and snug to the beveled edge or to the Basecap. Mark this
position using the 2 pre-punched holes in the Finishing Band as
a template. Pre-drill with a 3/32 metal drill bit and secure the
Finishing Band with the 2 supplied black sheet metal screws.
Figure 1B shows when it is all assembled.
Finishing
Band
Chimney
Pipe Adaptor
Selkirk Assembly
Finishing Band
to overlap the
Bead and snug
to the Beveled
edge of the
Chimney Pipe
Adaptor
Position
Finishing
Band over
the crimped
end
Position
Finishing
Band over
the crimped
end
Telescopic Length
Position
Finishing
Band snug to
the Basecap
Figure 1A
Figure 1B
Finishing Band Installed
Chimney
Pipe Adaptor
Finishing
Band
90 Degree Elbow
Finishing
Band
90 Degree Elbow
Supervent/Superpro
Assembly
Telescopic
Length
Figure 2B
Selkirk’s Assembly
Selkirk Assembly
INSTALLATION OF FINISHING BAND
(FB)
STEP 1 : SlidetheUniversal ChimneyAdapter (CA)overthe maleend
of either the Stove Pipe Adapter (ASE) or the Smoke Pipe Adaptor all
the way until snug to bead and beveled edge. See Figure 1.
INSTALLATIONOFTHEUNIVERSAL
CHIMNEYADAPTER
Basecap
NorthlineExpress.com
http://www.northlineexpress.com
Toll-Free 1-866-667-8454

"6"
"6"
INSTALLATION TYPE#3(SeeFigureC)
This installation is used when a factory built chimney system is
located through the wall behind the appliance.
1. Place the Telescopic Length on top of the appliance with the
male (crimped) end up, and the female end over the appliance
outlet collar . Attach it with the 3 metal screws supplied. If the
collar of your appliance is too large for the Telescopic Length to
fit over you will have to use a stove adapter on top of the stove
before installing the Telescopic Length.
2. Install a 90oElbow to the Chimney Adapter and then to the
chimney connector coming through the wall, ensuring that the
elbow is properly aligned for connection to the Telescopic Length.
If the clearances of the appliance requires a greater horizontal
distance than that provided by the 90oElbow, install the required
connector length totheelbow first,and then install your Chimney
Adapter and secure the pieces together with the 3 metal screws
provided. If using the Finishing Band see "Installation of Finishing
Band".
INSTALLATION TYPE#2(SeeFigureB)
This installation utilizing a Tee Section, is used when the chimney
systemisoffsetfromtheappliance, eithertomaintainproperclearances
for the appliance or for incorporating a cleanout in the chimney system.
1. Place the Telescopic Length on top of the appliance with the male
(crimped) end up, and the female end over the appliance outlet collar
and attach it with the 3 metal screws supplied. If the collar of your
appliance is too large for the Telescopic Length to fit over you will have
to use a stove adapter on top of the stove before installing the
Telescopic Length.
2. Install the 90oElbow to the Tee Section branch and the Univer-
Insulated Chimney Section
Chimney Pipe Adapter
3 Metal Screws
3 Metal Screws
3 Metal Screws
Telescopic Length
90oElbow
Tee
Section
Appliance
Finishing Band or Universal Chimney Adapter
Ceiling Support
FIGURE -B-
sal Chimney Adaptor to the top of the Tee. Secure the sections
together with the 3 metal screws supplied ensuring that the elbow
is properly aligned for connection to the Telescopic Length. See
"Installation of Finishing Band" if used.
3. Install the Elbow/Tee/Chimney Adapter assembly to the top of
the Telescopic Section and secure the sections together with the 3
metal screws supplied.
4. ExtendtheTelescopicLength untiltheChimneyAdapter slidesover
the chimney connector and secure the upper and lower sections of the
Telescopic Length in place with the 3 metal screws supplied. If the
installation requires more length than provided by the telescopic length
then install the fixed length(s) on the appliance and the telescopic
length next to the 90oElbow. All connections are to be fastened
together with the 3 metal screws provided with each length.
3 Metal Screws
Telescopic Length
3 Metal Screws
Chimney Support
ChimneySection
Appliance
FIGURE -A-
Chimney Pipe Adapter
Finishing Band or Universal Chimney Adapter
Insulated Chimney Length
3 Metal Screws
1. Place the Telescopic Length on top of the appliance with the male
(crimped) end up, and the female end over the appliance outlet collar.
Attach itwith the 3 metal screws supplied. If thecollar of your appliance
istoolargefor theTelescopicLengthtofitoveryouwillhavetouseastove
adapter on top of the stove before installing the Telescopic Length.
2. IfusinganUniversalChimney Adaptorplaceiton topof theTelescopic
Length and secure it in place with the 3 metal screws supplied. If using
the Finishing Band see "Installation of Finishing Band".
3. Extend the Telescopic Length until the Chimney Adapter slides over
the stove pipe adapter and secure the upper and lower sections of the
Telescopic Length in place with the 3 metal screws supplied. If the
installation requires more length than provided by the telescopic length
then install the fixed length(s) on the appliance and the telescopic length
next to the chimney. All connections are to be fastened together with the
3 metal screws provided with each length.
INSTALLATION TYPE#1(SeeFigureA)
This installation is used when the chimney system is located
immediately above the appliance.
NorthlineExpress.com
http://www.northlineexpress.com
Toll-Free 1-866-667-8454

"6"
"6"
"6"
INSTALLATIONTYPE#4(SeeFigureD)
This installation is the same as Installation Type #3 with the
exception that the Chimney connecter is run to an existing
Masonry Chimney instead of a Factory Built Chimney.
1. If your existing Masonry Chimney does not have a Chimney
Liner installed, it is required one be installed in order to make a
proper connection to the Double Wall Stove Pipe.
2. Once your Chimney liner is in place, make sure the opening in
the Chimney or liner is the correct size to accept the Masonry
Adapter. Slide the Masonry Adapter into the opening in the
chimney and into the branch of the Liner Tee until the collar of the
Adapter fits flush to the wall of the chimney. If Masonry Adapter
is too long and the collar does not fit flush to the wall, or it projects
too far into the Tee the Adapter should be trimmed for proper fit.
The Adapter should fit snug and not loose and there should be no
gaps where heat or products of combustion might escape. If the
adapter is loose fitting or gaps are present when it is installed they
should be filled with a suitable filler.
3. After installing the Masonry Adapter follow the instructions in
Installation Type #3.
FIGURE -D-
3 Metal Screws
3 Metal Screws
3 Metal Screws
3 Metal
Screws
Masonry
Adapter
3 Metal Screws
90oElbow
Appliance
Fixed Length Chimney
Liner
Masonry
Chimney
3 Metal Screws
3 Metal Screws
3 Metal Screws
Appliance
FIGURE -C-
Telescopic Length
Chimney Pipe Adapter
Finishing Band or
Universal Chimney Adapter
90oElbow
Telescopic Length
Insulated
Chimney
Sections
Insulated
Tee Section
WallThimble
12" Insulated
Section
Wall Support
Bracket
RULE FOR SAFE OPERATION AND MAINTENANCE
Do not use fuel materials corrosive to the chimney such as
driftwood, chemically treated wood or garbage or over fire your
solid fuel appliance. This can cause failure of the DSP Double
Wall Stove Pipe and will void any warranties.
When wood is burned slowly, it produces tar and other organic
vapors, which combine with expelled moisture to form creosote.
The creosote vapors condense in the relatively cool chimney flue
of a slow-burning fire. As a result, creosote residue accumulates
on the flue lining. When ignited, this creosote makes an extremely
hot fire.
Withanewinstallation,thechimneyshouldbeinspectedfrequently
(every 2 weeks if need be) to determine the rate of creosote
formation. When familiar with the appliance and chimney
characteristics, the chimney should be inspected at least once
every 2 months during the heating season to determine if a
creosote or soot build-up has occured.
If you see deposits more than 2mm (1/16") thick, clean all
connector pipe and chimney system mechanically (with a properly
sized plastic cleaning brush) to reduce the risk of chimney fire.
Contact a local professional chimney sweep for chimney cleaing
services and advice.
Do not expect chemical chimney cleaners to keep your chimney
clean. Their use does not negate the necessity of periodically
inspecting and cleaning your chimney.
KEEP YOUR CHIMNEY AND
CONNECTOR CLEAN!
3. Extend the Telescopic Length until it connects with the 90o
Elbow and secure the upper and lower sections of the Telescopic
Length in place with the 3 metal screws supplied. Fasten the
Telescopic Length and the 90oElbow together with the 3 metal
screws provided. If the installation requires more length than
provided by the telescopic length then install the fixed length(s) on
the appliance and the telescopic length next to the 90oElbow. All
connections are to be fastened together with the 3 metal screws
provided with each length.
NorthlineExpress.com
http://www.northlineexpress.com
Toll-Free 1-866-667-8454

LIMITED LIFETIME WARRANTY:
Selkirk Canada Corporation, ( “we”, “us”, “our”) warrants Chimney & Venting products * to be free from defects in material and workmanship
for as long as the original consumer owns the system. For products installed after January 1, 2000, for a period of Ten (10) years from original
installation,wewillprovidereplacement product with a similar or like quality of available product,freeofchargeexcludinganyinstallationcosts.
From the Eleventh (11) through Fifteenth (15) years we will provide replacement product to the original consumer at a cost of 75% off the
published Retail Price in effect on the date the claim is received excluding any installation costs. At expiration of the Fifteen (15) year term, we
willprovide replacement product to the originalconsumer at a cost of 50%off the published Retail Price ineffect on the date the claimisreceived
excluding any installation costs.
LIMITATIONS:
-Products must be installed for their intended purpose.
- Products must be connected to an appliance listed with an accredited testing laboratory.
WARNING: FAILURE TO INSTALL PRODUCTS ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS WILL VOID
ALL APPLICABLE WARRANTIES AND MAY RESULT IN FIRE, CARBON MONOXIDE POISONING OR DEATH. SEE
OUR PRODUCT INSTALLATION INSTRUCTIONS FOR COMPLETE INSTRUCTIONS.
WARRANTY COVERAGE:
All lengths, tees and elbows, and components are applicable to warranty coverage.
THIS LIMITED WARRANTY DOES NOT COVER:
(a) any non-stainless base tee unit mounted or connected to an Insulated Chimney system;
(b) costs (labor or otherwise **) associated with either removing a previously installed product, installing a replacement
product, transportation or return of a product, or transportation of replacement product;
(c) damage to the finish of products caused by the use of improper solvents/chemicals or improper cleaning methods;
(d) damage resulting from failure to reasonably clean, care for or maintain products in accordance with our installation instructions/
recommendations;
(e) damage (to products, appliances or structure) based on or resulting from improper installation or repair, misuse or abuse (including, but not
limited to, excessive or improper operating condition), or alteration or adjustment other than in conformity with our installation instructions and
specifications, whether performed by a contractor, service company, technician, or yourself;
(f) any products that have been moved from their original installation site.
(g) damage caused by burning driftwood, garbage, or any other prohibitive material has been burned in the appliance served by the chimney
(h) damage that results from accidents such as fire, flood, high winds, “acts of God”, or any other contingency beyond our control.
** Due to the wide variance in installation practices and other conditions beyond our control, we do not guarantee
or in any way warrant the installation of Chimney and Venting products.
CLAIM PROCEDURE:
If you believe that a product is defective, notify us in writing at the following location:
LIMITED LIFETIME WARRANTY
SELKIRK CANADA CORPORASELKIRK CANADA CORPORA
SELKIRK CANADA CORPORASELKIRK CANADA CORPORA
SELKIRK CANADA CORPORATIONTION
TIONTION
TION
P.O. Box 526, Depot 1,Hamilton,Ontario,CANADA,L8L7X6
ATTN: WARRANTY CLAIMS DEPARTMENT
Fax:(905)662-5352
Notification should include a description of the product, model and serial number (if applicable) and a description of the product defect. Upon
receipt of a written claim under this limited warranty and evidence of the date of purchase or installation, at our option and in our sole discretion,
we will provide replacement product with similar or like quality of available product excluding any installation costs. We reserve the right to
inspect or investigate any warranty claims prior to determining whether to provide replacement product. If, as determined by us that repair or
replacementof the product is not commercially practicableorcannot be completed in a timelymanner, we may refundtheproratedpurchaseprice
paid for the product upon verification by providing a copy of your invoice or receipt of bill of sale.
NorthlineExpress.com
http://www.northlineexpress.com
Toll-Free 1-866-667-8454

keep in safe place for future reference
MODEL OF CHIMNEY: _______________________________
TYPE OF APPLIANCE: ______________________________
INSTALLATION DATE: ____________________________
DESCRIPTION OF INSTALLATION (Chimney and Chimney Connector configuration) ______________
________________________________________________________________________________________
________________________________________________________________________________________
________________________________________________________________________________________
PURCHASED FROM:
DEALER NAME: _________________________________________________
Address: _________________________________________________
City: _________________________________________________
Province/State: _________________________________________________
INSTALLED BY:
TECHNICIAN NAME: _____________________________________________
Address: _____________________________________________
City: _____________________________________________
Province/State: _____________________________________________
Please register your Chimney with the Manufacturer.
Register Online: www.selkirkcanada.com
Name: _________________________________________________________________________
Address: _________________________________________________________________________
City: _________________________________________________________________________
Province/State: _________________________________ Postal/Zip: ___________________________
Model: _________________________________ Installation Date: ______________________
Dealer Name: __________________________
INSTALLATION INFORMATION
PRODUCT REGISTRATION
NorthlineExpress.com
http://www.northlineexpress.com
Toll-Free 1-866-667-8454
Table des matières
Autres manuels Selkirk Accessoires de cheminée
Manuels Accessoires de cheminée populaires d'autres marques

Bronpi
Bronpi KIT-1 Manuel utilisateur

Town & Country Fireplaces
Town & Country Fireplaces 22150051 Manuel utilisateur

Travis Industries
Travis Industries 33 DVI Manuel utilisateur

Superior
Superior ASD3628-TI Manuel utilisateur

pleasant hearth
pleasant hearth OFP28WG Manuel utilisateur

IHP
IHP Astria Series Manuel utilisateur

Firegear
Firegear FG-H-2110SS Manuel utilisateur

Nibe
Nibe Contura C i31 Manuel utilisateur

kozy heat
kozy heat KZK-052 Manuel utilisateur

SimpliFire
SimpliFire SF-WM36 Manuel utilisateur

Bluegrass Living
Bluegrass Living BC18NR Guide de démarrage rapide

pleasant hearth
pleasant hearth IRIS SCROLL Manuel utilisateur