Seek Thermal Scan Manuel utilisateur

USER MANUAL
TABLE OF CONTENTS
What’s In The Box.............................................................................................................................................................
System Setup......................................................................................................................................................................
Software Overview............................................................................................................................................................
View Settings......................................................................................................................................................................
General Settings & Kiosk Mode....................................................................................................................................
Station Settings..................................................................................................................................................................
Email Settings & About Menu.......................................................................................................................................
Data Options.......................................................................................................................................................................
Tips For Optimal Performance.....................................................................................................................................
Skin Temperature vs Body Temperature..................................................................................................................
Regulatory & Compliance...............................................................................................................................................
HEAT SOURCE
FIXED HEAT SOURCETHERMAL
CAMERA
VISIBLE
CAMERA Temperature-Controlled
Reference Device
9 cm
9.5 cm
8 cm 9 cm
Patents pending on Seek Scan System and Fixed Heat Source
SEEK SCAN DOES NOT DIAGNOSE COVID-19 OR OTHER DISEASE, ILLNESS OR DISORDERS.
THE SYSTEM MEASURES SKIN TEMPERATURE AS A PROXY FOR BODY TEMPERATURE.
CAMERA
HEAT SOURCE
2
3
4
5
6
7
8
9
10
11
12

2.
WHAT’S IN THE BOX
Camera Fixed Heat Source
USB Stick with
Seek Scan Software
Camera
USB-A Cable
Fixed Heat Source
Power Cable
Quick Start Guide Warranty
Removable for
international
power plugs

3.
SYSTEM SETUP
Connect USB stick to PC or tablet and follow
instructions to install Seek Scan software.
1. 2.
3. 4.
5. 6.
Place two pieces of tape 5 feet (1.5 m) apart.
Position is critical to system performance.
Set tripod heights to 5 feet (1.5 m).
Tripods not included.
Heat source automatically turns on once
plugged in. Ready when light stops blinking.
Attach camera to tripod and connect cable to
PC or tablet. Software must be already installed.
Heat source and subject should be NO
FURTHER than 5 feet (1.5 m) from the camera.

4.
SOFTWARE OVERVIEW
The heat source is not detected in the scene
and measurements will not be taken.
1.
This is your current alarm temperature. Adjust
this threshold in the General Settings menu.
3.
Green box means estimated body
temperature is below the alarm temperature.
5.
The heat source has shifted in temperature
and measurements will not be taken.
2.
Blue box means the camera has detected a
face and is measuring skin temperature.
4.
Red box means estimated body temperature
is above the alarm temperature.
6.

5.
VIEW SETTINGS
1. Choose between 5 viewing modes.
- Classic View includes a large visible image, a small
thermal image, and a graph of recent scans.
- Split View displays large visible and thermal images
side-by-side.
- Original View displays a full screen visible image.
- Thermal View displays a full screen thermal image.
- Text view displays only text.
2. Image Mirroring makes it easier for subjects to step in
and out of the frame like looking into a mirror.
3. Color Mode lets you decide the color of the thermal
image being displayed.
4. Choose to enable or disable temperature readings.
CLASSIC VIEW
Color mode shown: White Hot
SPLIT VIEW
Color mode shown: Spectra
TEXT VIEW
ORIGINAL VIEW THERMAL VIEW
Color mode shown: White Hot

6.
GENERAL SETTINGS
KIOSK MODE
1. Change between Celsius and Fahrenheit.
2. Turn alert sounds on or off.
3. Customize your temperature alarm threshold.
4. This allows the user to adjust the skin
temperature to estimated body temperature
offset for their own environment. Manual uses
a fixed offset that is configurable by the user.
Adaptive will automatically adjust the offset
based on your population.
5. Enabling Kiosk Mode locks the tablet to avoid
tampering or changing and disabling settings.
6. Check for the latest software updates at startup.
KIOSK MODE DISABLED KIOSK MODE ENABLED
UNLOCKING KIOSK MODE:
To unlock Kiosk Mode, click the lock icon in the
bottom right corner and enter CTRL + U. Kiosk
Mode works with all viewing and color modes.

7.
STATION SETTINGS
1. Camera software serial number.
2. Customizable camera station name.
Note: The station name is displayed in the Seek
Scan user interface.
3. Enable “Save Images” to store .jpg images of the
thermal camera, visible camera, and a screenshot
of the software screen at time of scan.
4. Enabling this feature sends anonymous system
data to Seek Thermal to help improve Seek Scan
software.
5. Export the last 24 hours of scan data and images
(if ‘Save Images’ was enabled).
The camera serial number and station name
fields will be grayed out until the thermal video
(black & white) is live in the Seek Scan software.
Open the settings menu to access these fields
after the camera is connected and live in the
Seek Scan software.
*
STATION NAME:
Your station name will appear here.

8.
EMAIL SETTINGS
ABOUT MENU
1. Displays your version of Seek Scan
Software/Firmware and camera software
serial number.
Click ‘Check for updates’ to check for
the latest Seek Scan software.
2. Click the clipboard icon to copy your
serial number.
3. Access the latest User Manual.
4. Visit our support site to resolve technical
issues and receive support if needed.
5. It is important to register your product
to activate your warranty and receive
the latest product information from Seek
Thermal.
1. Select the Send Email Alerts check box to send email
alert messages for scan measurements that are over
the Alarm Threshold.
2. Press this button to send a test email.
3. Fill in the appropriate email server settings for your
email provider.
This example shows the Microsoft Outlook email providers
SMTP Server address, SMTP Server port, and Secured
Socket Layer (SSL) setting. Please see support.thermal.com
for Gmail & Yahoo email provider examples.
4. Please enter the User Name (often email address)
and Password associated with the Email Provider’s
Email Account that will be sending the emails.
5. List the email address for the email account that will
be sending the email messages out.
6. List the email addresses for the Email Alert to be sent
to, please separate email addresses with a comma.
7. Select the Include Images check box to include
a visible image .png file of the Alert Scan. Select
Include overlay to include the temperature result
overlaid on the image emailed.
All of the Server Settings and Email Content fields
need to be properly filled out before a Test email can
be sent.
Images sent over email are not stored in Seek Scan’s
new encrypted database at this time.
*
*

9.
DATA OPTIONS
CSV TEMPERATURE LOG FILE
1. The CSV temperature log file is named ‘Temperature Data, date, time of download.’
E.g. Temperature Data 2020-09-01 091937.csv
2. There are six columns of scan information: customizable camera name, skin temperature, estimated
body temperature, customizable threshold temperature, ‘PASS’ or ‘FAIL’ disposition, and time of
scan.
3. ‘PASS or ‘FAIL’ disposition is denoted as follows: 1 = ‘PASS’ and 0 = ‘FAIL’
1. Inside the ‘PASS’ & ‘FAIL’ folders, individual
folders are created for each scan and are named
by the date and time of the scan.
2. Three different .jpg images are saved with each
scan: a screenshot of the Seek Scan software, a
thermal image, and a daylight camera image.
Each file name contains the time stamp, ‘PASS’
or ‘FAIL,’ and skin temp in °C.
JPG IMAGES
Seek Scan lets you to save images to its encrypted database running on the Windows PC C-Drive.
From the Station Settings menu, you can export a .zip file containing two folders, ‘PASS’ & ‘FAIL,’ of
scan image data from the last 24 hours.
The zip file will be empty if the ‘Save images’ check box is unchecked in the Station Settings menu.
* Images included in emails are not saved to the Seek Scan database.
Seek Scan saves temperature log data to its encrypted database running on the Windows PC C-Drive.
From the Station Settings menu, you can export a .csv file containing 6 columns of scan information
from the last 24 hours.

10.
TIPS FOR OPTIMAL PERFORMANCE
IDEAL SCREENING AREA
1. Locate a screening area in a stable, well-lit indoor controlled environment with a temperature
range 68-76°F (20-24°C) and relative humidity range from 10% to 50%.
2. Locate a screening area to avoid significant convective airflow from blowing onto or into the
screening area (e.g. from air conditioning ducts, or open doors or windows).
3. Locate a screening area to avoid thermal sources either hot or cold (i.e. sun-facing or cold
windows, radiant heaters, outside walls, strong lighting), particularly within the field of view of the
Seek Scan camera.
4. Backdrops and side screens can help ensure a controlled screening area. If used, they should be
thermally uniform, non-reflective, and not dark in color in the visible spectrum (closer to white
than black). Reflective panels such as glass panels should be avoided or covered with opaque
materials.
IDEAL SEEK SCAN SETUP
1. REMOVE GLASSES. Seek Scan targets the eyes first to make the most accurate measurement.
2. Set up your screening area with the camera pointed at the Heat Source in front of a wall. This will
help create a flat thermal background and allow for faster scan times and more reliable readings.
Warm objects in the background that are near a person’s skin temperature or warmer than 104°F
(40°C) may reduce system performance and stability.
3. Make sure that the subjects being scanned and the Fixed Heat Source are in the same position
in the scene during every scan. We recommend marking the ground with tape or floor decals to
ensure all subjects are measured from the exact same spot.
4. Confirm the distance from the Heat Source to the Camera is no further than 5 feet (1.5 meters).
Seek Scan has been qualified to work at 5 feet (1.5 meters) to accommodate people of different
heights. Seek Scan can work as close as 4 feet (1.2 meters) as well. In such a setup, Seek Scan
algorithms will work more efficiently but not cover has many different height variations.
5. It is very important to place the fixed heat source and the subject at the same relative distance
from the camera. Placing the heat source slightly behind or in front of the subject is acceptable,
try not to create more than 8 inches (0.2 meters) of separation. The heat source must remain
complete exposed and visible by the camera during every measurement.
6. It is important to remember that Seek Scan will focus primarily on the eyes to make a
measurement; therefore, only a person’s eyes and up need to be present in the scene.
SCREENING RECOMMENDATIONS
1. Subjects should look directly at the camera and remain still during measurement.
2. For more consistent readings, ensure the subject’s eyes are clearly exposed by removing any eye
wear. Subjects wearing a face mask should pull it down slightly, and subjects wearing a hat should
lift the brim to fully expose the eyes.
Ce manuel convient aux modèles suivants
1
Table des matières

















