Quantity
1
1
2
1
1
4/2
1. Packing List
Name
Standalone Proximity Reader
Infrared remote control
Manager card
Short Pin
User manual
Self Tapping Screws
Specification
W2
One for add, onefor delete
Used for factorydefault setting
W2
3.5*27mm
The W2 isfully waterproof standaloneProximity access Reader, which usesadvanced
microprocessor, equipped with large capacity Flash memory, supports up to 10,000
cards. It is soeasy to add or delete card users byusing the master card,besides, with
Infrared remote control programmer, the user can set the features bythemselves,
including Alarm, Self-protection, interlock and Anti-submarine back Function. In
additional, with infrared remote control programmer, you can add or delete cards
directly by inputtingcard number.
The W2 not only has the features of lowpower consumption, automatic selection of lock
,anti vandal alarmand exit button, but also hasthe protective functions against input over
voltage and outputsshort-circuit. These featuresmake the W2 safe , reliableand easy in
operation. It is anideal choice fordooraccess.
2. Description
Standalone Card Reader
User capacity: 10,000
Card interface: 125KHZ EMcard
Remote control forprogramming
With Manager cardsfor fast add
and delete users
Wiegand26 input/output
3. Features
Can be usedas salve reader
2 pcsW2 canbe interconnected/ interlocked
Can be usedas controller by connecting
slave reader
Anti-submarine back Function
Alarm signal output,Door open detection
Full of 10,000 users,recognizing speed <15ms.
4. Specifications
-20 60
20% 98%
Max20A
Max20A
Two
103 x 48 x23mm
Temperature
Humidity
Lock output load
Alarm output load
Manager card
Dimensions
Supply Voltage
Sleeping Current
Card type
CardReading Distance
Wiegand interface
User capacity
DC12V 10%
<15mA
125KHZ EM card
5 10cm
Wiegand 26
10,000
Drill holes onthe wall or prepare the cassette.
Wire through the hole,and blanket the unusedcable in case of short circuit.
Fix the backcover firmly on the cassette orthe wall.
Attach the readerto the back cover.
5. Installation
Shielded
cables
C
D
61mm
95.5mm
40mm
A
B
6. Wiring
No
1
2
3
4
5
6
7
8
9
10
Color
Yellow
Blue
Brown
Purple
Grey
Red
Black
White
Green
Orange
Function
D0
D1
ALARM+
OPEN
D_IN
12V
GND
VSS
L-
L+/Alarm+
Description
Wiegand output, inputsignal wire D0
Wiegand output, inputsignal wire D1
connecting to thenegative pole of the alarm equipment
Toconnect to one part of ExitButton
Door Contact input
(+) 12Vdc PositiveRegulated Power Input
(-) Negative RegulatedPower Input
the negative poleof the controller, connect tothe other
part of Exitbutton and door contact
Connect to the negativepole of the Lock
Connect to thepositive pole of the lock andalarm equipment
Connection Diagram
DC12V/3A
+
-
-
+Lock
-
+
Exit button
Alarm
door detecting switch
Common Power Supply
W2
D0
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
J1
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
DC12V/3A
+-COM
NC NO
PUSH
Exit button
Alarm
door detecting switch
Fail-securelock
Fail-safe lock
Special Power Supply
D0
ALARM-
J1
D1
Green
White
Grey
OPEN
D_IN
+12V
GND
VSS
L+
ALARM+
L-
Yellow
Brown
Red
Black
Blue
Purple
Orange
Toadd a card user(Method 2)
Todelete a carduser 2 Read Card # or
2 Card number (8digit) #
To deleteALL users.
(Note: This option will delete all users but
Manager Cards. Be carefulwith use) 2 0000 #
1 Input Card number (8 digit) #
The card numberis the last 8 digits ofthe
number printing onthe card.
Door open detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic
contact or built-in magnetic contact of the lock, if the door is opened normally, but
not closed after 1 minute, the inside buzzer will beep automatically to remind
people to close the door and continue for 1 minute before switching off
automatically.
Door Forced Openwarning. When usedwith an optionalmagnetic contact orbuilt in
magnetic contact ofthe lock, ifthe door isforced open, orif the dooris opened after
120 seconds of the electro-mechanical lock not closed properly, the inside buzzer
and alarm outputwill both operate.
Todisable door open detection.
(Factory default)
Security Mode Setting
Reader Lockout & Alarm Output options.If there are 10 invalid cardswithin 1 0 mi nutes,
the Reader will lockout for 10 minutes or the alarm will operatefor 10 minutes,
depending on theoption selected below.
Normal status (Nolockout or alarm) 7 0 # (Factory default setting)
Anti-submarine Disabled
Anti-submarine Master Mode
Antisubmarine Auxiliary Mode
(Note:the detailed wiring diagramand illustration, please referto the Advanced application ) .
(Factory default)
3 0 #
3 1 #
3 2 #
Toenable door open detection
6 0 #
6 1 #
Reader Lockout 7 1 #
Alarm Output 7 2 #
Door Interlock.
Door interlock disabled
Door interlock enabled
8 0 #
8 1 #
Alarm output time
To setthe alarm output time (0-3
minutes) Factory default is1 minute 9 0~3 #
I/O ALARM-
R8
R20
Q6
Lock Interface Principle:
By programme setting, I/O
switch between low leveland
high level.
4-low level
5-high level
I/O
L-
L+
+12V
R7 R19
Q2
D6
Alarm Interface Principle:
when alarm, the I/O outputs high level.
7. Interface Circuits
Figure 1
8. To Reset toFactory Default andManager Card setting
Power off, usethe supplied Contact Pin to shortout the 2P socket on themainboard,
then power on, if successful, the beeper will beep twice, the LEDshines in orange,
remove the Short Pin, then read any two EM cards, after thatthe LED turns in red,
means reset to factorydefault setting successfully. of thetwo EM cards read,the first
one is Manageradd card, the second one isManager delete card.
Remarks: Reset to factory default setting, the users' informationenrolled is still retained.
When reset toFactory default setting, the two Manager cards must be re-enrolled.
9. Sound andLight indication
Operation status
Reset to factorydefault setting
Sleeping mode
Operation successful
Enter into programmingmode
Enter into setting
Exist from programmingmode
Operation failed
Open the door
Alarm
LED
Orange
Red shines slow
Red shines
Orange shines
Red shines slow
Green shines
Red shines fast
Buzzer
Two shortring
Short ring
Short ring
Short ring
Short ring
Three short ring
Short ring
Alarm
10. W2 DetailedProgramming Guide
10.1 User settings
There are 2 waysto add and deleteusers:
A -By manager card; B - By remote control
A - ByManager card(The most convenient way)
To DeleteUser by Manager Card
B- By Remote control
Manager add card Read user card Manager
add card Cards can be added continuously.
Manager delete card Read user card Manager
Delete ca rd Cards canbe deletedcontinuously.
ToAdd user by ManagerCard
Toadd a card user (Method 1) 1 Read Card #
Card can beadded continuously without
exiting programming mode.
ToEnter the programming mode
Remarks:All thesteps below must be done afterentering into programmingmode
Tochange the master code 0 New Password # RepeatNew Password #
The master codemust be 6 8 digit number.
* Manager Password #
888888 is the defaultfactory master code
10.2 Door setting
Fail secure (Unlocked when power on)
Fail safe (unlocked whenpower is off)
4 0 99 #
0-99 is to setthe door relay time0-99 seconds.
5 0 99 #
0-99 is to setthe door relay time0-99 seconds.
Lock Power Setting
Anti-submarine Settings
This is the factorydefault, 3 seconds:
ToUnlock the door
To removethe alarm
Toremove the doorforcedopen warning Read valid card or Master Code#
Toremove the door open too long
warning Close the door orRead valid card
or Master Code#
Read user card
Note:that Manager Card can'tbe used to unlockthe door.
To Unlockthe door
Please ensure that allthe above contents arecorrect. If any aremissing, please notify thesupplier of the W2.
Do not poweron until all wiring has beencompleted
Note:The above diagrams show the output interface circuits. Unlike most lock and
alarm outputs which usea relay that canbe shocked or magnetized,the W2 uses MOS
outputs for both theLock Output on theleft and the Alarm Output on theright.
.2. .3. .4. .5.
.1. .6.