10 • Schlage • CO-100 user guide
Reset to factory defaults
All information in the main controller in the lock will be deleted and reset to factory defaults!
Main controller congurations that will reset to factory default include: programming and
user codes.
The door must be locked (not toggled open or in the middle of normal access) before
resetting to factory defaults.
Follow these steps to reset to factory defaults.
1. Remove the top inside cover.
2. Remove one battery from the battery pack to disrupt power. Wait 5 to 10 seconds for
power to run out in the lock.
3. Press and hold the Schlage button while reconnecting the battery into the battery pack
to resupply power.
4. Continue holding the Schlage button, and wait for two beeps to sound and two green
blinks of the Schlage button.
5. Release the Schlage button.
6. Press and release the Schlage button three (3) times within 10 seconds of the beeps
and blinks at step 4. One beep will sound and one red blink will occur with each press.
7. The Schlage button will light green for one second and a one-second beep will sound,
indicating that the lock has been reset.
LIf the Schlage button is not pressed 3 times within 10 seconds, two beeps and two
red blinks indicate timeout.
8. Replace the top inside cover.
To test, enter 13579 and “#”. The Schlage button will blink and the lock will unlock
momentarily.
Batteries
To install or replace alkaline batteries
LChanging batteries does not affect any programmed data.
1. Remove the battery cover.
2. Remove the battery bracket. Do not allow the battery pack to hang from the wires.
3. Install the new batteries (install only new AA Alkaline batteries). Make sure the batteries
are installed in the correct orientation.
4. Reinstall the battery pack and battery bracket.
5. Reinstall the battery cover, making sure the plug is to the right of the battery pack (CY,
MS and MD locks). Be careful not to pinch the battery wires when installing the
battery cover.
CAUTION! Danger of explosion if batteries are incorrectly replaced! Replace only with
new AA alkaline batteries. Dispose of used batteries according to the manufacturer’s
instructions.
This product has been evaluated for ULC-S319 compliance with AA and coin cell batteries
listed below. For installations requiring ULC-S319, these battery models should be used.
AA batteries: Duracell PC1500, MN1500; Energizer E91, EN91, AX91, XR91;
RayoVac 815, 815-HE
Coin cell batteries: Energizer CR2025, CR2032; Maxell CR2025, CR2032,