Saxun KIARA Manuel utilisateur

ENG
KIARA
TECHNICAL MANUAL

INDEX
1. GENERAL RECOMMENDATIONS REGARDING SAFETY, USE AND RESTRICTIONS 5
2. PARTS LIST AND SECTION 6
2.1 PARTS LIST KIARA 6
3. WIND RESISTANCE, CUTTING BOARDS AND SELECTION 7
3.1 WIND RESISTANCE (EN 13561) 7
3.2 MOTOR SELECTION 7
3.3 DEGREES OF INCLINATION 7
3.4 MINIMUM LINE ACCORDING TO ARM MEASUREMENT 8
3.5 MANUFACTURING DISCOUNTS 8
3.6 WALL TO WALL DISCOUNTS 8
4. VIEWS AND CROSS-SECTIONS 9
4.1 FIXTURE PLATE DIMENSIONAL CROSS-SECTION 9
4.2 SUPPORT INSTALLATION VIEW 9
5. ASSEMBLY AND INSTALLATION 10
5.1 IDENTIFICATION OF PARTS 10
5.2 ROLLING TUBE ASSEMBLY 11
5.3 AWNING PROFILES ASSEMBLY 11
5.4 AWNING ASSEMBLY 12
5.5 ANGLE OF THE AWNING 13
5.6 SUPPORTS ASSEMBLY 13
5.7 MOTOR ASSEMBLY 14
5.8 BRACKET ASSEMBLY 14
5.9 TERMINAL ASSEMBLY 15
5.10 BRACKET ADJUSTMENT 15
5.11 AWNING CAPS ASSEMBLY 16
5.12 INSTALLATION INSTRUCTIONS 17

6. MAINTENANCE 20
6.1 CLEANING AND CARE 20
7. ANNEX I 20
7.1 WHAT TO DO IN CASE OF EMERGENCY 20
8. ANNEX II 21
8.1 MOTOR CONFIGURATION 21
9. ANNEX III 34
9.1 DISASSEMBLY AND DISPOSAL OF THE PACKAGING AND COMPONENTS OF THE PRODUCT AT THE END
OF ITS USEFUL LIFE 34
IMPORTANT
It is important to read these instructions carefully
before installation, operation, repair or first use, in
order to protect the safety of persons and to the
integrity of the product.


TECHNICAL MANUAL KIARA
5
Should any damage and/or a system malfunction be detected, do not continue with the installation.
The manufacturer will not be liable for damage caused during the installation due to non-compliance with these
recommendations.
In order to ensure the safe assembly, use and main-
tenance of this product, a number of precautionary
measures must be taken. Please observe the following
warnings and instructions, for the safety of all con-
cerned.
Please contact your distributor with any queries.
- This manual is intended as a reference for experi-
enced professionals and should therefore not be used
by DIY amateurs or trainee fitters.
- This manual describes the installation of the product
assembly components, and refers to the electrical
control installation manuals. if necessary, this manual
should be supplemented with instructions for any ad-
ditional components not described herein.
-Please read this manual carefully before starting work.
- Some components may be sharp or have jagged edg-
es. It is therefore advisable to wear safety gloves.
- All parts supplied have been designed specifically
for this product. The replacement or addition of oth-
er parts may have a negative eect on the safety of
the product and its warranty. In addition, the CE certi-
fication of this product will become invalid if any parts
are replaced or if the installation is not carried out in
accordance with the instructions in this manual. The
installer shall accept full responsibility in this regard.
- Ensure that the assembly area is suciently illumi-
nated. Remove any obstacles or dirt. Make sure no-
body is present besides the fitters. Unauthorised
persons (especially children!) may interfere or cause
hazards during installation.
Before assembly, it is very IMPORTANT for your safety
and that of the product to follow all the recommentions
listed below. A poor-quality installation may cause
harm to people or damage to the installation itself.
Once the product has been unpacked, the professional
fitter has to check its integrity. Before starting the in-
stallation, the arrangement of all components and tools
must be checked in order install the product correctly.
In case of doubt, contact Giménez Ganga´stechnical
department.
Under no circumstances should a damaged product be
installed, as it may damage the equipment and create
situations that are dangerous for people.
These systems are exclusively intended for the use for
which they were designed. Any other use is inappropri-
ate, and therefore dangerous.
The system installation must always be performed by a
professional fitter, respecting the manufacturer´s indi-
cations, as well as knowing and applying all the regula-
tions in force.
IMPORTANT
For power operated products, the existing voltage must be checked before
installation.
The connection must always be a grounded connection. Otherwise, do not continue the installation as it may
be dangerous.
1. GENERAL RECOMMENDATIONS REGARDING SAFETY, USE AND
RESTRICTIONS

6
CODE COMPONENTS
1
024716
Kiara Awning Caps Wall Kit
1A
024754
Kiara Awning Caps Ceiling Kit
2
024702
Kiara Awning Wall Kit
2A
024753
Kiara Awning Ceiling Kit
3
024737
Kiara canopy profile
4
024628
Box profile Kiara
4A
024627
Box profile Kiara - LED
CODE COMPONENTS
5
024629
BC pro le Kiara
6
024739
Diuser profile LED 17x5.3 mm
7
022807
Axle Ø80
8
024738
Protector PVC profile Kiara
9
024741
Set retractable arms LADA
9A
024740
Set retractable arms LUMME
2 | 2A
1 | 1A
9 | 9A
4 | 4A
6
8
3
7
5
1 | 1A
1 | 1A
1 | 1A
1 | 1A
1 | 1A
2 | 2A
2 | 2A
2 | 2A
2 | 2A
2.1 PARTS LIST KIARA
2. PARTS LIST AND SECTION

TECHNICAL MANUAL KIARA
7
WIND RESISTANCE EN 13561
PROJECTION
WIDTH
2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00 5.25 5.50 5.75 6.00
1.50 22222222222222222
1.75 2222222222222222
2.00 222222222222222
2.25 22222222222222
2.50 2222222222222
2.75 222222222222
3.00 22222222222
3.25 2222221111
3.50 222221111
3.75 22221111
4.00 1111111
Class 2 ≈ 38 Km/hClass 1 ≈29 Km/h
3.1 WIND RESISTANCE (EN 13561)
3.2 MOTOR SELECTION
MOTOR SELECTION (Nm)
Projection (m) 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00
Axle Ø80 mm 30 Nm 40 Nm 50 Nm
3.3 DEGREES OF INCLINATION
75º
0,25
0,50
0,75
1,00
1,25
1,50
1,75
2,00
2,25
2,50
2,75
3,00
3,25
3,50
3,75
4,00
1,50
2,00
2,50
2,75
3,00
3,25
3,50
4,00
WIDHT (m)
ARM PROJECTION (m)
10º
20º
30º
40º
50º
60º
70º
80º
90º
0º
DEGREES OF INCLINATION
Front installation 0º - 75º
Ceiling with plate installation 17º - 75º
Ceiling installation with square 0º - 75º
Wall to wall installation 0º - 75º
3. WIND RESISTANCE, CUTTING BOARDS AND SELECTION

8
MINIMUM LINE ACCORDING TO ARM MEASUREMENT (m)
PROJECTION (m) MINIMUM LINE (m)
Motor
1.25 1.51
1.50 1.76
1.75 2.01
2.00 2.26
2.25 2.51
2.50 2.76
2.75 3.01
3.00 3.26
3.25 3.51
3.50 3.76
3.75 4.01
4.00 4.26
3.4 MINIMUM LINE ACCORDING TO ARM MEASUREMENT
REDUCTIONS (mm)
Motor Somfy
Axle Ø80 L-148
Canvas L-164
Profiles and load bar (aluminium) L-144
Profiles ( PVC) L-145
3.5 MANUFACTURING DISCOUNTS
3.6 WALL TO WALL DISCOUNTS
TOTAL DISTANCE BETWEEN WALLS
L
43 43

TECHNICAL MANUAL KIARA
9
4. VIEWS AND CROSS-SECTIONS
4.1 FIXTURE PLATE DIMENSIONAL CROSS-SECTION
Ceiling with square Wall to wall
Wall Ceiling
4.2 SUPPORT INSTALLATION VIEW
130
30.75
2450.501824.50
18.50
80.50
133.50
13.50
65
20.75
8.50
42.50
Ø11Ø11
Ø11
204
242
175
271
70
200
153
267
189
271

10
5. ASSEMBLY AND INSTALLATION
5.1 IDENTIFICATION OF PARTS
Mobile support
A
Fixed support
B
B
B
B
A
Left support
B
A
Right support
Motor/dot support Fixture plates Multi-motor support
Load bar
Canopy
Box awing Power strip kit Screws
Table des matières
Autres manuels Saxun Accessoires