RT Systems TM3 Manuel utilisateur

TM3 monitoring
unit
installation and
users manual

1
contents
introduction 2
product description 2
document overview 3
product certication 3
related documents 3
physical description 4
inventory 7
additional parts 8
installation 9
install the TM3 unit 9
power cord, network cable
and GSM antenna connections 10
sensor connection 11
temperature sensors 11
ood sensors 11
dry contacts 11
4-20mA sensors 12
relay connection 12
initial configuration 13
before the unit is used operationally the following
minimum conguration is required 13
set the time and date 13
connecting laptop to TM3 14
GSM conguration 15
ethernet/internet conguration (rst time) 17
configuration 19
contact conguration page 20
alarm prole conguration page 21
dry contact alarm conguration page 22
analogue alarms conguration page 24
transmission selection 24
analogue names 25
conguration page 26
4-20mA sensor conguration page 27
self test conguration page 29
temperature sensor conguration page 30
disabled alarms conguration page 32
uncleared alarms conguration page 33
general conguration page 34
camera conguration page 35
SNMP conguration page 36
security conguration page 37
log out page 38
front panel functions 39
temp 39
self test 40
disable/enable all alarms 41
clock 41
enter 41
GSM sms data access 42
view data 45
home page 46
alarm log 47
graph view 48
camera view 49
SNMP 50
maintenance 51
trouble shooting 52
clean the TM3 monitoring unit 53
disposal 53
specifications 54

2
product description
The TM3 Monitoring Unit is a generic environmental monitoring system, capable of interfacing to various
sensors and communicating sensor status on Ethernet (web based), GSM and SNMP. Sensors which can be
connected include NTC temperature sensors, flood sensors, dry contacts and third party 4-20mA sensors.
introduction
The unit can be congured through the web interface and by SMS. Temperature Thresholds can also
be congured on the front panel keypad interface. Sensor levels and thresholds, alarm descriptions,
alarm proles, contact details and communication data are congurable on the unit.
The TM3 Unit is capable of logging alarms and analogue sampled data which can be viewed from the
web interface. Images from a network enabled camera can be viewed on the web interface. Two
onboard relays for controlling external devices and a 12Vdc and 18Vdc power supplies are available on
the unit. The unit has battery backup capability during mains power failure. Onboard SD card saves all
programmed information. In the event of a unit failing the SD card is removed from the faulty unit and
inserted into a new unit and the TM3 is ready to monitor.

3
document overview
The TM3 Unit Installation and Users Manual describes how to install a TM3 Monitoring Unit, how sensors are connected and conguration
of the sensor inputs is performed. It also describes maintenance and fault nding. After performing the installation and conguration
procedures as set out in this document, the TM3 Unit is ready for installation specic conguration and operational environmental
monitoring.
product certification
The TM3 Unit CE certication is pending. The following IEC specications are applicable to the TM3 Monitoring Unit:
nElectrical Fast Transients (EFT) IEC 61000-4-4
nElectrostatic Discharge (ESD) IEC 61000-4-2
nSurges IEC 61000-4-5
nRadiated Susceptibility IEC 801-3
nVoltage Dips and Interruptions IEC 61000-4-11
nConducted Susceptibility IEC 61000-4-6
nEmissions and Harmonics IEC 61000-3-3 and IEC 61000-3-2
nGeneral Products Safety Directive 2001/95/EC
nRoHS Compliance 2002/95/EC
related documents
Unless otherwise noted, the following documentation and software is available on the CD provided with the device or on the applicable
product page on the RT Systems website www.rtsystems.co.za
nInstallation and Users Manual
nICASA Approval Certicate
nGSM Module Certication Data
nIP Set Software
nIOD’s
nTM3 Base Station Programming Software.
Refer to the software help le for installation and users instructions.
nSD card default conguration les
nSNMP mib le

4
front panel
physical description
8 9 11
1 2 3 4 5
10
7
6
item description
1TRM GSM Transmit Indicator
This is a red LED and will light up during GSM transmission and reception.
2TEMP
Temperature setup select key
The temperature sensor thresholds and calibration settings are congured when selecting the TEMP key.
Press twice in succession to calibrate the sensors.
3
Down key
The down key is used to scroll through menus and decrement numerical values during system conguration
and setup.
4Right key
The right key is used to move the cursor to the right during system conguration and setup.
5ENTER
Enter key
Press Enter to enter the telemetry menu where raw input data can be viewed. The Enter key is also used to
save setup data.

55
item description
6LCD Liquid Crystal Display
The LCD displays all the system data.
7GSM
GSM Status Indicator
nFlashing once every second – Initialising, not registered on the GSM network.
nFlashing once every three seconds – Registered on GSM network.
8SELF TEST Self test select key
By selecting the Self Test key the unit performs a sequence of tests to determine its own health status.
9
Up key
The up key is used to scroll through menus and increment numerical values during system conguration
and setup
10
Left key/Clock/Cancel
This is a multifunction key. Press to set up the time and date of the unit. When in a setup menu this key
can be used to move the cursor to the left. This key is also used to cancel menu selections when in a menu
select mode.
11
DISABLE
ALL
ALARMS
Disable All Alarms
By selecting this key all alarms will be disabled. To enable alarms select key or unit enables alarms after
one hour. This will be indicated on the LCD and on the Web interface.

6
item description
1GSM ANTENNA
CONNECTOR SMA connector for GSM antenna connection.
2 VOLTAGE OUTPUT Provides one 18V dc, 50mA voltage output for sensor supply voltage.
34-20MA INPUTS Three 4-20mA inputs available for connecting third party sensors.
4TEMPERATURE
SENSOR INPUTS Four inputs available to connect NTC temperature sensors.
5FLOOD SENSOR
INPUTS Two inputs available for multiple ood sensors in series terminated with a 10k end of line resistor.
6VOLTAGE OUTPUT Provide two 12V dc, 200mA voltage outputs for sensor supply voltage.
7DRY CONTACT
INPUTS Eight dry contacts available for dry contacts.
8DRY CONTACT
INPUTS Seven dry contacts available for dry contacts.
9RELAY OUTPUTS Used for relay controlled external devices.
10 10/100 BASE-T
NETWORK PORT Provides for a 10/100 Base-T network connection with status and link LEDs indicate network trafc.
11 ON/OFF On/Off switch for unit power.
12 INLET FUSE Provides for input power protection. See maintenance parts for fuse rating.
13 AC LINE INLET Provides for the input power connection. See specication on page 54 for voltage information.
back panel
1 2 54 6 7 8 93
10 131211

77
inventory
Inspect the contents of the package to ensure that the parts included match those shown below. Report
missing or damaged contents to RT Systems or your TM3 reseller. However, if damage was due to shipping,
immediately report the damage to the shipping agent.
item description
The shipping and packaging materials are recyclable. Please save them for later use or dispose of them
appropriately.
TM3 monitoring unit
The main component in the shipment.
utility cd
The utility CD contains the Installation and Users Manual, Certication data, TM3 Base Station Programming Software, IP Set Software,
SNMP MIB le, OID’S, SD card default conguration les and Freeware SNMP browser link.
SD card
The SD Card is installed on the TM3 Monitoring Unit and contains default conguration data.
10 position terminal block
Included are six terminal blocks for interfacing to the terminals at the back of the TM3 Monitoring Unit.
GSM antenna
A GSM antenna is supplied. The antenna has a magnetic base for easy tment.
power cord:
A mains lead with BS 546 plug is supplied.
cross-over ethernet cable
The supplied cross-over Ethernet cable is used for interface directly to a laptop.
installation pack
The supplied installation pack consists of 10 cable ties, 4 screws for mounting TM3 unit on 19” rack and 6 cable tie mounts.

8
additional parts
Additional parts are not supplied with the TM3 Unit. These parts are installation specific and are supplied
by the installer.
NTC temperature sensors
Analogue sensor.
humidity/temperature sensor (dry contact)
Alerts are activated by means of a contact closing/opening when threshold is reached.
flood sensor
The water detector will detect potential ood risks in the server room caused by condensation water form air cons or burst
water pipes.
4-20mA current transducer
Monitor the amperage of ups and generator distribution boards.
4-20mA humidity sensor
Monitor humidity in server rooms. High humidity – condensation. Low humidity – static.
smoke detector sensor
An important addition to security and safety. These smoke detectors are easy to install and congure. The smoke detector must be
mounted on the ceiling for maximum smoke detection.
door contact sensor
Monitor and be alerted when there is access to server rooms, server cabinets.

99
installation
install the TM3 Unit
The TM3 Monitoring Unit is enclosed in a standard 1U 19” enclosure. Install the unit in the front of the rack, which requires one U of
rack space. When installing the TM3 Monitoring Unit, take into consideration the following:
symbol description
C
Caution: Only connect approved devices to ports on the unit as directed in this manual. Plugging in other
devices may result in equipment damage.
N
Note: Install the appliance in an environment compatible with the maximum ambient temperature specied
in “Specications” on page 54. Units installed in a closed or multi-unit rack assembly can experience a
greater operating ambient temperature than the ambient room temperature.
N
Note: Install the unit in a way that allows sufcient airow for safe operation.
N
Note: When you install the unit in the rack, be sure that you do not create a hazardous condition due to
uneven mechanical loading. For example, do not use the unit as a shelf.
N
Note: When you install the GSM antenna, be sure that you have good GSM reception. Install the antenna
preferably outside the rack assembly for improved reception.
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur