RP LIGHTING 1070W Manuel utilisateur

1070W,1080W
For Models:
Installation Guide
Net Weight Of 1070WFan: 30.5lbs (13.85kgs)
Net Weight Of 1080WFan: 35.3lbs (16.05kgs)

TOOLS AND MATERIALS REQUIRED
PACKAGE CONTENTS
2
1
2.3
SAFETY RULES
4
5
5.6
MAKING ELECTRICAL CONNECTIONS
6
8
7
10
11.12
13
13
9
9
TROUBLESHOOTING
CARE OF YOUR FAN
MOUNTING OPTIONS
CANOPY ASSEMBLY
ATTACHING THE FAN BLADES
INSTALLING THE BOTTOM CAP
HANGING THE FAN MOTOR ASSEMBLY
Table of Contents
HANGER BRACKET INSTALLATION
FAN ASSEMBLY
INSTALLING WALL CONTROL & OPERATION
INSTALLING THE LIGHT KIT (optional)

1
Do not use water or detergents when cleaning
the fan or fan blades. A dry soft cloth or lightly
dampened cloth will be suitable for most
cleaning.
lbs(32kgs)
ft.(3M)
Safety Rules
OUTDOOR USE- Suitable for use in wet locations
when installed in a GFCI protected branch circuit.

2
Ladder
Wire Strippers
Phillips Screwdriver
Adjustable wrench
Pliers
Tools & Materials Required
For Mounting Hanger bracket:
l. Hardware packs included
Wood Screws & Washers
x5
Qty
Hanger Bracket Screws,
Spring Washers, Flat Washers x2 each
x2
Spare motor screw &
Washer
x1
x1 set
x8
Wire Nuts
Balance Kit
For Blade Installation:
Blade Screws
& Fiber W
ashers
x22
(one spare screw,fiber washer included)
These mounting screws are intended for use solely in wooden
structure ceilings. For concrete ceilings and suspended
ceilings, appropriate screws are required (not included).
Package Contents
a. Blade
b. Blade Holder
c. Hanger Bracket
d. Waterproof Cover
e. Canopy
f. 8” Downrod with Ball
g. 24“ Downrod
h. Motor Coupling Cover
i. Fan Motor Assembly
j. Bottom Cap
k. DC ceiling fan wall control(wall controller & driver)
Parts Qty
x7 pieces
x7
x1
x1
x1
x1
x1
x1
x1
x1

j
i
k
f g
h
l
1 2 3 4 5
IOII
SPEED
REVERSAL
OFF
FANON FAN &
LIGHT ON
3
Unpacking Fan
*Fan blade bracket screws
to the fan blade bracket.
Parts Guide- Model Number 1070W, 1080W

4
35 lbs (15.9kgs).
At the end of the blade must be a minimum of
2 meters away from the wall. There must be a
distance of 3 meters between two ceiling fans.
6M (20ft.)
6M ( 20ft.)
blade edge
Outlet box
Outlet box
Outlet box
Fig.1
Fig.2
Fig.3
Fig.4
Ceiling joists
Ceiling
Secure the outlet box directly tothe building structure.
Use appropriate fasteners and building materials.
To reduce the risk of fire, electric shock, or personal
Injury, mount to outlet box marked "acceptable for
fan support of 70 lbs (32 kgs) " and use mounting
screws provided with the outlet box.
Most outlet boxes commonly used for the support
of luminaries are not acceptable for fan support and
may need to be replaced.
Mounting Options
10 ft
(3M)
6.6ft
(2M)

5
Hanger Bracket Installation
Remember to turn off the power. Follow the steps
below to hang your fan properly. NOTE: This ceiling
fan is supplied with the hanging assemblies; the
standard ceiling installation using the downrod with
ball and hanger bracket mounting installation.
Fig.5
Ground wire
spring wishers
Hanger bracket
Hanger bracket
screws
Flat washers
Supply wires
120VAC 60Hz Outlet box
Waterproof
Cover
Your ceiling fan will require a grounded electrical
supply line of 120VAC 60HZ, 15Amp Circuit.
Step 1.
Pass the 120V supply wires through the
waterproof cover and hanger bracket.(Fig.5)
Step 2.
Secure the waterproof cover and hanger
bracket to the ceiling outlet box with
screws and washers included with
mounting hardware.
Fan Assembly
Motor
Loosen setscrew on hanging ball
to free the lock pin, remove the ground screw and
ground wire, and save all parts.
Feed fan wires & safety cable up through the
downrod.
NOTE: Make sure the wires are on one side and
the safety cable on the other side. (Fig. 6b)
Be careful that wires are pulled through, make
sure the wires do not get twisted.
Insert the downrod into the coupler, and align
holes with holes in the coupler on the top of the
motor housing.
IInsert the hitch pin through the coupler and
downrod, secure with nut and lock pin.
NOTE: Proceed with this step in order
**Fan Assembly continued on next page.**
Fig.6a
Fig.6b
Downrod
Motor Wires &
Light Wires
Safety Cable
Security Screw(x2)
Coupling cover
lock clip
Pin #2
lock clip
Pin #1
1
2
IMPORTANT: Securely fasten the downrod using
two security screws onto the coupler to prevent
shaking during fan operation.
1 2

6
With the hanger bracket secured to
the outlet box and able to support the fan,
you are ready to hang the fan. Hold the fan
firmly with two hands. Lift the fan assembly
onto the hanger bracket.
Ensure the registration slot of the ball joint is
positioned on the stopper of the hanger bracket
to prevent the fan from rotating when in operation.
WARNING: Failure to align slot in hanging ball
with stopper(tab) in hanger bracket may result in
serious injury or death.
Tip: Seek the help of another person to hold
the stepladder in place and help lift the fan up
to you once you are set on the ladder.
Waterproof
Cover
Hanger Bracket Stopper
Safety cable
screw with
washer
WOOD MEMBER
(2” X 4” APPROX.) CEILING JOIST
CEILING
OUTLET BOX
HANGER BRACKET
Hanging the Fan Motor Assemply
Install the safety cable to ceiling
using the screw (ST5x38mm) &
wasers.
Place the coupling cover over the downrod
assembly.
Place canopy over downrod.
Replace the hanging ball on downrod,
insert the lock pin through downrod, and
tighten the set screw in the hanging ball
against downrod.
WARNING: Failure to tighten set screw on
the hanging ball completely could result in
the fan possibly falling.
set screw
Safety Cable
Cross Pin
Canopy
Downrod

DONOT USE THIS DC MOTOR FAN IN
CONJUNCTION WITH ANY VARIABLE
(RHEOSTAT) WALL CONTROL OR
REMOTE CONTROL.
7
WARNING: This fan must use the matching DC fan wall
control designed for use on this fan.
Can NOT indicate other speed control or the like.
WARNING: To reduce the risk of electric shock, this
fan must be installed with an isolating general-use
wall control / switch.
Lock protection - The DC motor has a build-in safety
feature against blade or motor obstruction during operation.
If something obstructs the fan blades or motor, the motor
will keep trying to run and then stop operation after about
20-30 seconds of interruption. Remove obstacles and
use wall control included with this fan.
The DC fan receiver provides protective functions.
Over load protection (current limit) - The device limit
the maximum current output from the receiver/drive
when the fan load was increased abnormally.
Refer to wiring diagram making correct wire connections.
NOTE: This fan must be installed by a licensed electrician.
After wire connections have been made, turn leads upward
and carefully push the white wire and black wire connections
into the outlet box. The other connections should be spread
apart neatly and place on both side of the hanger bracket.
WARNING: Check to see that all connections are tight,
including ground connection. DO NOT operate fan until
the blades are secured in place.
Making Electrical Connections
WARNING:
electrician and obtain service.
NOTE:
can be cut to the desired length and stripped.
When fan is secured in place on the hanger
DRIVER
TO MOTOR(PINK)
TO MOTOR(GREY)
TO MOTOR(RED)
FOR LIGHT NEUTRAL(WHITE)
FOR LIGHT
LIVE(BLUE)
BLACK
WHITE
YELLOW/GREEN
YELLOW/GREEN
GREEN GROUND
OUTLET BOX
IN CEILING
GROUND TO
HANGER BRACKET
& DOWNROD
FAN
LIGHT
WH
WH
BLUE
BLACK
BLACK (TO MOTOR L)
WHITE (TO MOTOR N)
BLACK(TO AC L)
INPUT VOLT. 120V
WHITE (TO AC N)
DC Fan
Wall Control

View after installation
Waterproof Cover
8
Canopy Assembly
Outlet Box
Canopy
Screws
Coupling Cover
Hanger Bracket
After connecting the wires,
place the DC fan driver in hanger bracket
as shown, turn the leads upward and
separate wire connections and put
neatly inside of the outlet box.
Locate the two screws on the underside
of the hanger bracket.
Attach the canopy to the hanger bracket
by placing the screws into the slot in the
canopy, then twist clockwise to lock it
into place, and tighten the screws firmly.
Autres manuels pour 1070W
1
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels RP LIGHTING Ventilateur

RP LIGHTING
RP LIGHTING 1052 Manuel utilisateur

RP LIGHTING
RP LIGHTING 1088 Manuel utilisateur

RP LIGHTING
RP LIGHTING 1076 Manuel utilisateur

RP LIGHTING
RP LIGHTING 1021-PC Manuel utilisateur

RP LIGHTING
RP LIGHTING 1060 Manuel utilisateur

RP LIGHTING
RP LIGHTING 1072-PC Manuel utilisateur

RP LIGHTING
RP LIGHTING 1073LED-PC Manuel utilisateur

RP LIGHTING
RP LIGHTING 1070 Manuel utilisateur

RP LIGHTING
RP LIGHTING 1070W Manuel utilisateur