Rongta Technology RLS Series Manuel utilisateur

RLS Series User Manual
XIAMEN RONGTA TECHNOLOGY CO.,LTD.
Add: 3F/E Building, Gaoqi Industrial Area Gaoqi Beisan Road Dianqian Huli Xiamen, China
Tel: 0592-5666129 Fax:0592-5659169
Service hot-line:400-800-0596
Website: www.rongtatech.com
V1.2

Contents
INTRODUCTION..........................................................................................................1
1. THE HANGING SCALE’S SPECIFICATION...................................................... 2
2. STANDARD EQUIPMENT...................................................................................... 2
3. FEATURES SUMMARY.......................................................................................... 3
3.1 Unique and powerful network..........................................................................3
3.2 Usage is easy to learn....................................................................................... 3
3.3 Advanced functions and durable quality.......................................................... 3
4. HANGING SCALE INSTALLATION STEPS..........................................................4
4.1 Installation........................................................................................................ 4
4.2 The installation of the thermal label paper....................................................... 5
4.3 Description of label paper................................................................................ 6
4.4 The keyboard.................................................................................................... 6
5. OVERALL APPEARANCE.......................................................................................7
6. COMMON EASY-TO -USE OPERATIONS............................................................ 8
6.1 Switch on and off............................................................................................. 8
6.2 Weighing and pricing....................................................................................... 9
6.3 Peeling/Tare operation......................................................................................9
6.4 Discount..........................................................................................................10
6.5 Rate changing................................................................................................. 10
6.5.1 Permanent changes in the price........................................................... 10
6.5.2 One-time price change.........................................................................10
6.6 Select weight unit........................................................................................... 11
6.7 Accounting by number or quantity................................................................. 11
6.8 Automatic fast packaging............................................................................... 11
6.9 Operation button in common use................................................................... 11
7. FUNCTION SETTING............................................................................................ 12
7.1 Input settings of single item........................................................................... 12
7.2 System set up..................................................................................................13
7.3 Lock................................................................................................................14
8. TROUBLESHOOTING........................................................................................... 15
8.1 Scales crash.................................................................................................... 15
8.2 Print related issues..........................................................................................15
8.3 The key issues................................................................................................ 18
8.4 Weigh problem............................................................................................... 18
8.5 Communication problem................................................................................19
8.6 Error code.......................................................................................................19
8.7 Other problems............................................................................................... 19
9. THE ACCELERATION OF GRAVITY REVISED TABLE................................... 21

1
Introduction
Thank you for choosing our hanging scale In order to operate RLS correctly, User manual is detailed in
function and operation method of RLS , which help user with doubt quickly when come up against mechanical
fault .
Rongta research, develop, produce and sale RLS independently, which is high-performance .
Hanging scale is the best choice for user in label printing business line with fashional appearance, power
function and high durable, which make hanging scale more popular in store ,fresh food supermarket ,farmers
market and so on.
Note : this product information are subject to change without prior notice.
This information is for reference only. In addition to China's existing laws and regulations, the company does not
undertake any due to the direct or indirect losses caused by use of this information.
The company reserves the final interpretation.

2
1. The hanging scale’s specification
The Weighing range and accuracy.
RLS1315 RLS1330
Max weight: 6kg/15kg Max weight: 15kg/30kg
Min weight: 40g Min weight: 100g
0kg to 6kg * 0.002kg (e=2g) 0kg to 15kg * 0.005kg (e=5g)
6kg to 15kg * 0.005kg (e=5g) 15kg to 30kg * 0.010kg (e=10g)
The accuracy grade:
Ⅲ
Resolution:
Input sensitivity: greater than or equal to 50u V/D
zero-point adjustment range: ±60MV
temperature coefficient: ±0.0012%CTYP
[Zero] ±(0.2μV+0.0008% of Dead Load)/℃TYP
Nonlinearity: 0.01%F.S.
A/D resolution: Max 30000 resolution
Display resolution: 1/3000
A/D conversion rate: 6 times/second
LCD display board:
Info/weight: 5byte(APHA)
simple lattice: 8 byte
Total lattice: 8byte
Unit of weight: g. kg.
Regular:
Power supply: 100V-240V~, 50/60Hz
Power consumption: Standby 3W, line printing 30W
operating temperature: 0 ℃-40 ℃
physical appearance: Length 437mm width372mm high 523mm
2. Standard Equipment
a. Mainframe
b. Scale
c. Scale support - A
d. Scale support - B
e. Thermal label paper
f. A Fuse , Six of M4 screw, A M5 hand the screw
g. Operation Manual
h. Serial port cord
i. Power cord

3
3. Features Summary
3.1 Unique and powerful network
a. Use the Ethernet interface technology and the data transfer rate has been improved drastically
3.2 Usage is easy to learn
a. Operate the PLU by single bond to make fast sales, and the front desk staff could use it without training.
b. 56 direct buttons and 112 hot buttons can be set up, and the common goods can be specified to hot buttons
mostly.
3.3 Advanced functions and durable quality.
a. The under machine program can be upgraded by PC, the program will be the latest version and the function
would be the most perfect forever.
b. The design of the Printer structure is exquisite, is not easy to roll the paper.
c. Barcode rotation could extend the lifetime of the print head, and the printer mechanism could be adjusted
according to the paper’s sensitivity.
d. Having the function of weighing and pricing for the various packages, along with special designed barcode
printing.
e. Function: It can use a few goods to make up to platter, fruit basket, etc.
f. Each PLU could be set to multiple tags.
g. Each PLU could be used by separated barcode encoding formats, which could solve the encoding problem
from distribution and consignment sales.
h. Each PLU could use separated units.
i. The unit of quantity could be self defined, such as block, packages, etc
j. PLU has abundant information, Including barcode format, fresh code, package type, information provision,
etc.
k. Rotational printing the whole label.
l. Support Ean-8, Ean-13 and 18 code, completely solving the problem of fresh commodities code.
m. Unique bar code type to manage the fresh commodities by batch

4
4. Hanging Scale Installation Steps
4.1 Installation
1. Open the cover, and reach the power 2. Install the suspender accessories, and place the pallet
plug into from the top for connection
4.Install the load tray onto the 5. Installation finished
weighing scale, and fasten the screw
The cover
screw
Note: rails with 'counterweight' must be
mounted on the pallet
3. Remove the sensor
mounting bracket on the
bottom of the scale
screw

5
4.2 The installation of the thermal label paper
(1)Open the right cover (2)Contrarotate, and then open the print head
(3) Pull out the stopper to install the paper roll, if the installation of a small roll of paper need to be
screwed out of the paper shaft group, remove the two large paper roll shaft
(4) Check the direction of label (5)Tear off the first pieces of the label paper, and
Paper indicated by the arrow pass through leading Paper device by following
the direction of arrow.

6
(6) Follow the direction of arrow, making the (7)Press [↑] key to wind the paper
front end of the roll paper bypass the filter board.
wind the paper into the winding shaft, and then
close the print head.
(8) Install limit block and close the right cover
4.3 Description of label paper
The label which is used at RONGTA hanging scale is: Thermal Seam Marking Label. As shown below:
Height:60mm,width:(30~60)mm,Max outside diameter: 100mm,Minimun inner diameter:40mm or 26.8mm .
inner diameter 26.8mm
inner diameter 40mm

7
4.4 The keyboard
Press []、[] button to adjust label position and long press [] button to align paper.
keyboard
5. Overall Appearance
Front View Left View

8
Right View Back View
6. Common easy-to -use operations
6.1 Switch on and off
Hard disk switch on/turn on: After connecting power supply, switch on the power button at the top of the
hanging scale After the screen shows one by one the information of edition No., IP address, self-test countdown
“0 、1、2、……8”, the scale enter into sale pattern.
Vertical view 1 Vertical view 2
Attention: under self-test situation, please do not press any button and make sure nothing is on the scale,
otherwise it can’t work normally.
switch
Autres manuels pour RLS Series
2
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Rongta Technology Échelle

Rongta Technology
Rongta Technology AURORA Y1 Manuel utilisateur

Rongta Technology
Rongta Technology AURORA S1 Manuel utilisateur

Rongta Technology
Rongta Technology RLS Series Manuel utilisateur

Rongta Technology
Rongta Technology RLS1515 Manuel utilisateur

Rongta Technology
Rongta Technology RLS1000 Manuel utilisateur

Rongta Technology
Rongta Technology RLS Series Manuel utilisateur

Rongta Technology
Rongta Technology RLS1000 Manuel utilisateur

Rongta Technology
Rongta Technology C1 Manuel utilisateur

Rongta Technology
Rongta Technology LS015 Manuel utilisateur