Renssi RCM-25 Manuel utilisateur

Jobsite Health & Safety is a first priority matter here at
Renssi®. To extend this priority to our customers and end-
users, we have created this extensive Safety Manual for you to
rely on when working with our products.
SAFETY INFO
READ BEFORE USE OF TOOL
WARNING!
These instructions are for your own, personal
safety. Always make sure that you have read
and understood these instructions carefully
before using Renssi® Tools.
RCM-25 INSTRUCTIONS 06/2019
KEEP FOR THE FUTURE USE!

2
RCM-25

3
CONTROL UNIT
RCM-25
A
B
C
D
E
F
CONTROLS
A.
B.
C.
Emergency STOP button
Main switch
Direction switch
D.
E.
F.
Main voltage indicator
Speed controller
Emergency STOP reset button
RCM-25

1. INTRODUCTION
2. GENERAL POWER TOOL SAFETY WARNINGS
2.1.0 Work Area Safety
2.2.0 Electrical Safety
2.3.0 Personal Safety
2.4.0 Power Tool and Use
3. INSTALLING THE RCM-25
4. OPERATING THE RCM-25
5. TURNING OFF THE RCM-25
6. MAINTENANCE
7. ATTACHMENTS
8. NOTES
TABLE OF CONTENT
To watch practical demonstration videos,
or to download a digital copy of this manual,
please visit http://renssi.com/en/downloads
Please note that demonstration videos, where available,
are not intended as a replacement or alternative
to this Safety Manual.
5
5
6
6
7
8
9
10
11
12
13
14

5
MODEL
RCM-25
MODEL INFORMATION
RCM-25 unit is intended to be used in cleaning sewer pipes and reinstating after relining process.
Before a successful relining process, the pipe needs to be well cleaned. RCM-25 unit is designed
to rotate a cable with a cleaning or cutting tool at the end of the cable.
This manual must be available to the operators/maintenance personnel at all times.
SPECIFICATIONS
Size: 450 mm x 740 mm x 950 mm
Weight: 85 kg + control unit 12 kg
Cable size: 10 mm, 12 mm
Cable length: 25 meters
Max. RPM: 2800/min*
Output: 1500 W
* = max. RPM 1500/min when using 110V operating voltages.
1. INTRODUCTION
WARNING!
Read all safety warnings and instructions.
If the warnings and instructions are not followed, there are possibility of an electric
shock, fire / or serious injury.
2. GENERAL POWER TOOL SAFETY WARNINGS
ATTENTION!
Save all warnings and all instructions for future reference.
The term “power tool” in the warnings refers to your mains-operated
(corded) power tool.

6
2.1.0 WORK AREA SAFETY
1. Keep work area clean and well lit.
Cluttered or dark areas invite accidents.
2. Do not operate power tools in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust.
Power tools create sparks which may ignite the dust or fumes.
3. Keep children and bystanders away while operating a power tool.
Distractions can cause you to loose control.
2.2.0 ELECTRICAL SAFETY
1. Power tool plugs must match the outlet. Never modify the plug in any way.
Do not use any adapter plugs with earthed (grounded) power tools.
Unmodified plugs and matching outlets will reduce risk of electric shock.
2. Avoid body contact with earthed or grounded surfaces, such as pipes, radiators or
refridgerators.
There is an increased risk of an electric shock if your body is earthed or grounded.
3. Do not expose power tools to rain or moisture.
Risk of electric shock increases, if the water enters into power tool.
4. Do not abuse the cord. Do not carry or pull the power tool, or pull the plug by pulling the
cord. Keep the cord away from heat, oil, sharp edges and moving parts.
Damaged or entangled cords increase the risk of electric shock.
5. When operating a power tool outdoors, use proper extension of cord for outdoors.
Suitable cord for outdoor use reduces the risk of an electric shock.
6. If the use of a power tool in a damp location is necessary, use a residual current device
(RCD) protected power source.
Use of an RCD reduces the risk of electric shock.

7
2.3.0 PERSONAL SAFETY
1. Stay alert, be careful and use the power tool with caution.
Do not use the power tool when you are tired or under the influence of alcohol or drugs. Losing
concentration for a moment can cause serious personal injury.
2. Use personal protective equipment.
Always wear a safety glasses. Protective equipment such as a respirator, safety shoes, helmet and
hearing protection used for appropriate conditions will reduce personal injuries.
3. Prevent unintentional starting.
Make sure that the power switch is off position before connecting to power source and/or battery
pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or
energising power tools that have the switch on invites accidents. Remove any adjusting key or
wrench before turning the power tool on.
A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
4. Do not overreach.
Keep proper footing and balance at all times. This enables better control of the power tool in
unexpected situations.
5. Dress properly.
Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away from moving
parts. Loose clothes, jewellery or long hair can be caught in moving parts.
6. If device is provided with a connection for dust extraction and collection facilities,
ensure that these are connected and properly used.
Use of dust collection system can reduce dust-related hazards.
PERSONAL PROTECTIVE EQUIPMENT
Use protective gloves and clothing
Use sealed protective goggles
Use face/breathing protection
Use ear protection
Risk of crushing
Risk of corrosion
High noise levels
Serious hearing damage

8
2.4.0 POWER TOOL AND USE
1. Do not force the power tool. Use the correct power tool for your application.
The correct power tool will do the job better and safer at the rate for which it was
designed.
2. Do not use the power tool if the switch does not turn it on and off.
Any power tool that cannot be controlled with the switch is dangerous and must be
repaired.
3. Disconnect the plug from the power source and/or the battery packfrom the power
tool before making any adjustments, changing accessories, or storing power tools.
Such preventive safety measures reduce the risk of starting the power tool accidentally.
4. Store idle power tools out of reach of children and do not allow persons unfamiliar
with the power tool or these instructions to operate the power tool.
Power tools are dangerous in the hands of untrained users.
5. Maintain power tools.
Check for misalignements or binding of moving parts, breakage of parts and any other
condition that may affect the power tool’s operation. If damaged, have the power tool
repaired before the use. Many accidents are caused by poorly maintained
power tools.
6. Keep cutting tools sharp and clean.
Properly maintained cutting tools with sharp cutting edges are less likely to bind and are
easier to control.
7. Use the power tool, accessories and tool bits etc. in accordance with these
instructions, taking into account the working conditions and the work to be performed.
Use the power tool for operations different from those intented could result in hazardous
situation.
ATTENTION!
Have your power tool serviced by a qualified repair person using only
identical replacement parts.

9
3. INSTALLING THE RCM-25
1. Connect the control unit to the motor with the orange 6 pin cable.
2. Connect the foot pedal to the control unit.
3. Connect the power cord to the control unit.
4. Make sure that the power cord plug matches the power outlet.
5. Plug the RCM-25 unit to the power outlet.

10
4. OPERATING THE RCM-25
WARNING!
Improper use of the machine can cause serious damage.
1. Use the Renssi® equipment always on a solid surface to prevent equipment from falling.
2. Press the Emergency STOP-button.
3. Turn the Main switch to power ON the unit. ( Main voltage light will illuminate )
4. Choose the desired rotation direction with Direction Rev./For-switch.
5. Choose the desired rotation speed. ( Can be adjusted while used )
6. Release the Emergency STOP-button.
7. Press the Emergency STOP Reset-button. ( Blue light will illuminate )
8. Keep a firm grip on the cable and set your body so that working position is as natural as possible.
Always make sure that you do not need to change your grip during operation.
9. Never place the rotating equipment near your arm.
Equipment can cause the cable to swing around which can lead to serious injuries.
10. Start the machine by pressing the foot pedal.
11. The machine stops when you take your foot off the pedal.
A
B
C
E
A
F
Table des matières

















