REMKO EFS Series Manuel utilisateur

Operating and
installation instructions
Read the instructions prior to performing any task!
REMKO EFS series
EFS 21
Fresh water station
0321-2022-11 Edition 1, en_GB
Instructions for users and specialists

Translation of the original
Read these operating instructions carefully before commis-
sioning / using this device!
These instructions are an integral part of the system and must
always be kept near or on the device.
Subject to modifications; No liability accepted for errors or mis-
prints!

Table of contents
1 Safety and usage instructions............................................................................................................. 4
1.1 General safety notes....................................................................................................................... 4
1.2 Identification of notes...................................................................................................................... 4
1.3 Personnel qualifications.................................................................................................................. 4
1.4 Dangers of failure to observe the safety notes................................................................................ 4
1.5 Safety-conscious working............................................................................................................... 4
1.6 Safety instructions for the operator................................................................................................. 5
1.7 Safety notes for installation and inspection tasks........................................................................... 5
1.8 Unauthorised modification and changes......................................................................................... 5
1.9 Intended use................................................................................................................................... 6
1.10 Safety-conscious working............................................................................................................. 6
1.11 Warranty........................................................................................................................................ 6
1.12 Transportation and packaging....................................................................................................... 6
1.13 Environmental protection and recycling........................................................................................ 6
2 Technical data........................................................................................................................................ 7
2.1 Unit data.......................................................................................................................................... 7
2.2 Unit dimensions and space requirements....................................................................................... 8
2.3 Pump data....................................................................................................................................... 8
3 Design and planning........................................................................................................................... 10
3.1 General notes................................................................................................................................ 10
3.2 Design of the storage tank............................................................................................................ 11
3.3 Setting the Temperature................................................................................................................ 12
3.4 Corrosion protection...................................................................................................................... 13
3.5 Calcification protection.................................................................................................................. 14
4 Assembly............................................................................................................................................. 15
5 Hydraulic connection.......................................................................................................................... 16
6 Electrical wiring................................................................................................................................... 17
7 Commissioning (specialist)............................................................................................................... 18
7.1 Leak test and filling of the system................................................................................................. 18
7.2 Initial commissioning..................................................................................................................... 18
7.3 Gravity brake................................................................................................................................. 18
7.4 Maximum dispensing medium flow rate........................................................................................ 19
7.5 Circulation operation..................................................................................................................... 21
7.6 Commissioning report................................................................................................................... 22
8 Shutdown............................................................................................................................................. 22
9 Troubleshooting and customer service ........................................................................................... 23
10 Care and maintenance........................................................................................................................ 24
11 View of the unit and spare parts........................................................................................................ 25
12 Index..................................................................................................................................................... 26
3

1 Safety and
usage instructions
1.1 General safety notes
Carefully read the operating manual before com-
missioning the units for the first time. It contains
useful tips and notes such as hazard warnings to
prevent personal injury and material damage.
Failure to follow the directions in this manual not
only presents a danger to people, the environment
and the system itself, but will void any claims for
liability.
Keep this operating manual and the refrigerant
data sheet near to the units.
1.2 Identification of notes
This section provides an overview of all important
safety aspects for proper protection of people and
safe and fault-free operation.The instructions and
safety notes contained within this manual must be
observed in order to prevent accidents, personal
injury and material damage.
Notes attached directly to the units must be
observed in their entirety and be kept in a fully
legible condition.
Safety notes in this manual are indicated by sym-
bols. Safety notes are introduced with signal words
which help to highlight the magnitude of the danger
in question.
DANGER!
Contact with live parts poses an immediate
danger of death due to electric shock. Damage
to the insulation or individual components may
pose a danger of death.
DANGER!
This combination of symbol and signal word
warns of a situation in which there is immediate
danger, which if not avoided may be fatal or
cause serious injury.
WARNING!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may be fatal or cause
serious injury.
CAUTION!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause injury or mate-
rial and environmental damage.
NOTICE!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause material and
environmental damage.
This symbol highlights useful tips and recom-
mendations as well as information for efficient
and fault-free operation.
1.3 Personnel qualifications
Personnel responsible for commissioning, opera-
tion, maintenance, inspection and installation must
be able to demonstrate that they hold a qualifica-
tion which proves their ability to undertake the
work.
1.4 Dangers of failure to observe
the safety notes
Failure to observe the safety notes may pose a risk
to people, the environment and the units. Failure to
observe the safety notes may void any claims for
damages.
In particular, failure to observe the safety notes
may pose the following risks:
nThe failure of important unit functions.
nThe failure of prescribed methods of mainte-
nance and repair.
nDanger to people on account of electrical and
mechanical effects.
1.5 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
REMKO EFS series
4

1.6 Safety instructions
for the operator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
nThe units and components may only be set up,
installed and maintained by qualified per-
sonnel.
nThe existing regulations concerning accident
prevention must be adhered to.
nDo not operate units or components with
obvious defects or signs of damage.
nContact with equipment parts or components
can lead to burns or injury.
nEnsure that electrical energy does not pose a
risk.
nRegulations of the VDE and the local energy
supply company must be adhered to.
NOTICE!
Material damage due to mineral oils!
Mineral oil products permanently damage
EPDM seal elements; the sealing properties
may therefore be lost. We do not take responsi-
bility or provide warranty replacements for
damage caused by seals that are damaged in
this way.
–It is essential that you prevent EPDM from
coming into contact with mineral oil sub-
stances.
–Use a lubricant that is free of mineral oil and
has a silicone or polyalkylene basis, such
as Unisilkon L250L and Syntheso Glep 1
made by Klüber, or a silicon spray.
1.7 Safety notes for installation and
inspection tasks
nThe operator must ensure that all inspection
and installation work is carried out by author-
ised and qualified personnel who have thor-
oughly read the operating manual.
nWorks on the pump/system may only be car-
ried out whilst at a standstill as a matter of prin-
ciple.
nAppropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
nThe setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
nRegional regulations and laws as well as the
Water Ecology Act must be observed.
nThe power supply should be adapted to the
requirements of the units.
nThe units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
nSafety devices may not be modified or
bypassed.
NOTICE!
Malfunction!
The fresh water module must be integrated into
the equipotential bonding system of the elec-
trical installation. If this is not ensured by the
pipe network, set up an approved potential
equalisation connection to the main potential
connection.
1.8 Unauthorised modification and
changes
The operational safety of the fresh water module
that was delivered is guaranteed only with
intended use in accordance with section 1.8 of the
operating instructions. Under no circumstances
should the threshold values specified in the data-
sheet be exceeded.
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufacturer ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
5

1.9 Intended use
The fresh water module is only permitted to be
installed in heating systems between the buffer
tank and the domestic water circuit. Depending on
the design, it may only be installed and operated
vertically!
Use only REMKO accessories in conjunction with
the fresh water module.
Any different or additional use is a non-intended
use. The manufacturer/supplier assumes no lia-
bility for damages arising from a non-intended use.
The user bears the sole risk in such cases.
Intended use also includes working in accordance
with the operating and installation instructions and
complying with the maintenance requirements.
The threshold values specified in the technical
data must not be exceeded.
1.10 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
1.11 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.
1.12 Transportation and
packaging
The units are shipped in sturdy transport pack-
aging or within the heat pump housing. Immedi-
ately check the units on delivery and make a note
of any damage or missing parts on the delivery
note. Inform the forwarding agent and contractual
partner. Claims under guarantee made at a later
date will not be accepted.
WARNING!
Plastic films and bags etc. are dangerous
toys for children!
Why:
- Leave packaging material are not around.
- Packaging material may not be accessible to
children!
1.13 Environmental protection and
recycling
Disposing of packaging
All products are packed for transport in environ-
mentally friendly materials. Make a valuable contri-
bution to reducing waste and sustaining raw mate-
rials. Only dispose of packaging at approved
collection points.
Disposing of the units and their components
For the manufacture of the units and components,
only recyclable materials have been used. Help
protect the environment by ensuring that the units
or components (for example batteries) are not dis-
posed of in household waste, but only in accord-
ance with local regulations and in an environmen-
tally safe manner, e.g. using authorised disposal
and recycling specialists or council collection
points.
REMKO EFS series
6

2 Technical data
2.1 Unit data
Series EFS 21
Nominal power at 10-45/65°C (KW-WW/HVL) kW 100
Tap capacity at nominal power l/min 41
Min. switch-on flow rate for primary pump l/min 2.0
NL count at nominal power 9.5
Power at 10-60/75°C (KW-WW/HVL) kW 104/194/291/388
Tap capacity at 10-60/75°C (incl. cascades) l/min 30/56/84/112
Capacity at 10-60/75°C, mixed to 45°C DHW kW 104
Tap capacity at 10-60/75°C, mixed to 45°C DHW (incl. cas-
cades) l/min 43/80/120/160
NL count at 10-60/75°C (incl. cascades) 10/32/62/96
Max. operating pressure for heating side bar 3
Max. operating pressure for service water side bar 10
Max. operating temperature for heating side °C 95
Max. operating temperature for service water side °C 65
Connections, heating side Inches 3/4" IG
Connections, service water side Inches 3/4" IG / 1" AG
Pressure loss, service water side at nominal power bar
0.67
Max. pressure loss for heating side piping mbar 50
Wilo PARA circulation pump power consumption W 3-45
Medium flow rate probe Huba probe type 235 2-40 l/min
Electrical wiring (mains regulation) V/Hz 230 V AC/50-60 Hz
Housing / Connecting parts
Housing / connecting parts
CW617N (2.0402) CW617N
(2.0402)
Plate heat exchanger Cu, soldered
Seals AFM
Insulation EPP foam 0.038 W/mK
We reserve the right to make technical changes for the purpose of technical advancement.
7

2.2 Unit dimensions and space requirements
Fig. 1: Unit dimensions
2.3 Pump data
Pressure loss characteristic curve
A
B
Fig. 2: Pressure loss characteristic curve
A: Wilo PARA 15/7 B: EFS 21
Specified pressure loss valid for heating (primary) and drinking water side (secondary).
REMKO EFS series
8

PWM logic (PWM 2)
Fig. 3: PWM logic
< 7 % Pump off
7-12 % Min. performance (operation)
12-15 % Min. performance (start-up)
15-95 % Proportional performance range
> 95 % Max. power
We reserve the right to make technical changes for the purpose of technical advancement.
9

3 Design and planning
3.1 General notes
The fresh water station is a fresh water module
that heats domestic water according to the contin-
uous flow heater principle. In order to ensure fault-
free operation of the fresh water station, the
system must fulfil certain prerequisites. Before
installation, take some time for planning.
NOTICE!
Storage tank mounting is only possible with
mounting templates (accessories).
CAUTION!
Danger of scalding due to hot water!
Due to external circulation in the primary circuit,
water with a temperature of up to 90 °C can
leak out at the dispensing connection.
–No external pumps are permitted to be
installed between the fresh water module
and the buffer tank.
–The fresh water module is not permitted to
be connected to a heating cycle distributor.
Installation example
This hydraulic diagram serves merely to assist in planning activities;
the hydraulic system on site must be planned and laid out by the installer!
Subject to technical changes!
A
A
1
B
2 3 4 5
Fig. 4: Fresh water station with optional circulation set and optional return distribution
A: Fresh water station
B: REMKO MPS storage tank
1: Cold water
2: Hot water
3: Unmixed heating cycle
4: Mixed heating cycle 1
5: Mixed heating cycle 2
REMKO EFS series
10
Autres manuels pour EFS Series
4
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels REMKO Système d'eau
Manuels Système d'eau populaires d'autres marques

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuel utilisateur

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuel utilisateur

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuel utilisateur

Microline
Microline T.F.C.-4 Manuel

Eureka Forbes
Eureka Forbes Aquaguard Select Manuel utilisateur

Cetetherm
Cetetherm AquaEfficiency Manuel utilisateur












