1. Contents
1. Contents................................................................................................................. 2
2. Capabilities............................................................................................................. 3
2.1 Features...........................................................................................................................3
3. Physical Layout...................................................................................................... 4
4. Basic Operation...................................................................................................... 5
4.1 Log Data ..........................................................................................................................7
4.2 Resume Logging............................................................................................................10
4.3 Delete Data....................................................................................................................11
4.4 View Job Information .....................................................................................................13
4.5 Plot Chart.......................................................................................................................14
4.6 Print Data.......................................................................................................................16
5. Configuration........................................................................................................ 18
5.1 Set Date.........................................................................................................................19
5.2 Set Time.........................................................................................................................21
5.3 Configure Ports..............................................................................................................23
5.3.1 Show Port Function.................................................................................................24
5.3.2 Set Port Function.....................................................................................................25
5.3.3 Set Port Speed........................................................................................................26
5.3.4 Set Port Format.......................................................................................................28
5.3.5 Port Test..................................................................................................................30
5.4 Set Depth Units..............................................................................................................31
5.5 Plot Delay.......................................................................................................................32
5.6 Set Password.................................................................................................................33
6. Troubleshooting.................................................................................................... 35
7. Sample Chart ....................................................................................................... 36
8. Sample Log..........................................................................................................37
9. Limited Warranty..................................................................................................38

Reliable Scale Corporation
Model DL-04 DATA-LOGGER
User Manual Page 3 of 38 Rev. 1.70
2. Capabilities
The Model DL-04 DATA-LOGGER is a versatile tool designed to record line
load, line speed and tool depth on Wireline trucks.
This new technology offers secure data recovery and reduces chances of operator
error and improves record keeping. The result is an improved profit picture.
The DL-04 stores data accurately without interfering with the operator’s normal
activities.
The DL-04 monitors the truck’s digital weight indicator, depth meter and line speed
meter as often as every 2 seconds and stores the information securely in memory.
This allows the manager to review very closely the details of each job.
2.1 Features
• Lists job description, operator ID, job date
• Each record includes record number, line load, line speed, depth, and time of
day
• Stores up to 113,825 records (over 63 hours of continuous recording at 2 second
log intervals)
• Reads data at 2 second to 99 second intervals
• Support for 115,200 bps serial transfers
• XON/XOFF flow control for serial transfers

Reliable Scale Corporation
Model DL-04 DATA-LOGGER
User Manual Page 4 of 38 Rev. 1.70
3. Physical Layout
• 12 Volt DC Power Input - 4 pin male military style connector (P/N: PT02A8-
4P).
• LCD Screen - displays instruction and status messages to the operator.
• Alphanumeric Keys - operator keys in information.
• Data Control Keys - for Entering and Editing data.
• RS-232 Ports - 4 pin female military style connectors (P/N: PT02A8-4S) to
connect devices to the DL-04. Example: Digital Scale, Personal Computer, Line
speed indicator.
• Arrow Keys - to scroll through menus and stored information.
• Function Keys - to issue commands; keys are assigned different functions as
listed on the LCD screen.
• Power Key - to turn the DL-04 on and off.

Reliable Scale Corporation
Model DL-04 DATA-LOGGER
User Manual Page 5 of 38 Rev. 1.70
4. Basic Operation
1. Press the
ON/OFF key until text appears.
Screen shows the serial number and the
software version.
RELIABLE SCALE
DL-04 DATA-LOGGER
S/N: 9903148
Version 1.60
The next screen shows date & time for
operator verification with local time
zones.
RELIABLE SCALE
DL-04 DATA-LOGGER
1999-03-29 14:09:23
F1: Continue
2. Press F1 to continue.
Screen shows the first two options
available from the Main Menu. MAIN MENU
1 Log Data
2 Resume Logging
Select # more:T
3. Use the UP and DOWN arrow keys to
scroll through all the options.
MAIN MENU
3 Delete Data
4 View Data
Select # more:S
MAIN MENU
5 Plot Chart
6 Print Data
Select # more:S
4. Select the option you wish to use.
Example: 1Log Data

Reliable Scale Corporation
Model DL-04 DATA-LOGGER
User Manual Page 6 of 38 Rev. 1.70
5. When an process has been completed,
the DL-04 will return to the Main Menu. MAIN MENU
1 Log Data
2 Resume Logging
Select # more:T

Reliable Scale Corporation
Model DL-04 DATA-LOGGER
User Manual Page 7 of 38 Rev. 1.70
4.1 Log Data
The chief function of the DL-04 is the Log Data process.
The screen prompts the operator through the necessary steps, issuing
instructions as required. Once the operator initiates a job, each record is
saved automatically for future transfer and analysis.
Once logging has begun, the screen is updated every log interval with
the latest log information. This maintains a record of:
• Tool Depth with units
• Line Speed with units
• Entry Time
• Line Load with units
• Entry Number (max. 113,825)
1. From the Main Menu, select Log
Data.
MAIN MENU
1 Log Data
2 Resume Logging
Select # more:T
Operator is prompted for required
information starting with Well Name
Well Name:
F2: Alpha
F4: Quit ENTR: Accept
2. Key in the Well name.
Example: K14 If letters are used press
F2to enter alpha mode
The screen will change slightly Well Name:
F2: Accept alpha
f: Next position

Reliable Scale Corporation
Model DL-04 DATA-LOGGER
User Manual Page 8 of 38 Rev. 1.70
3. Press the number and arrow
keys to scroll through the
letters shown at the top of the
keys.
4. Use F2 to exit alpha mode and the
screen will return to normal
Well Name:
K
F2: Alpha
F4: Quit ENTR: Accept
5. Input numbers normally
6. Well Number is next. Follow the
same procedure as for Well Name.
Well Number:
F2: Alpha
F4: Quit ENTR: Accept
7. Key in Well Number.
Example: 45
Well Number:
45
F2: Alpha
F4: Quit ENTR: Accept
8. Wireline Job Type is next. Follow
the same procedure as for Well
Name.
Wireline Job Type:
F2: Alpha
F4: Quit ENTR: Accept
9. Key in Wireline Job Type.
Example: COMPLETION
Wireline Job Type:
COMPLETION
F2: Alpha
F4: Quit ENTR: Accept

Reliable Scale Corporation
Model DL-04 DATA-LOGGER
User Manual Page 9 of 38 Rev. 1.70
10.Job Operator is next. Follow the
same procedure as for Well Name.
Job Operator:
F2: Alpha
F4: Quit ENTR: Accept
11.Key in Job Operator.
Example: 58
Job Operator:
58
F2: Alpha
F4: Quit ENTR: Accept
Log Interval is next. Intervals from 2
seconds to 99 seconds between
records are available.
Log Interval(s):
Min: 2s Max: 99s
F4: Quit ENTR: Accept
12.Key in the Interval.
Example: 2
The DL-04 begins reading data every
2 seconds.
LOGGING. . .
256.42m 122m/m
10:23:10 4990kg
F4: Quit 000085
13.Logging can be interrupted by
pressing F4.

Reliable Scale Corporation
Model DL-04 DATA-LOGGER
User Manual Page 10 of 38 Rev. 1.70
4.2 Resume Logging
If a job has been interrupted for some reason, it can be resumed using
the Resume Logging process. Only the last job in memory can be
resumed. If there are no jobs in memory, this process cannot be used.
1. From the Main Menu, select Resume
Logging.
MAIN MENU
1 Log Data
2 Resume Logging
Select # more:T
The operator is asked to confirm the
resume operation.
LOGGING. . .
Resume Job # 3?
F2: Confirm
F4: Cancel
2. Press F2 to confirm resumption.
3. The DL-04 Resumes logging
Resuming Job #: 3
LOGGING. . .
256.42m 122m/m
10:23:10 4990kg
F4: Quit 000085
4. Logging can be interrupted by
pressing F4.
Table des matières
Manuels Matériel réseau populaires d'autres marques

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuel utilisateur

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuel utilisateur

Yudor
Yudor YDS-16 Manuel utilisateur

D-Link
D-Link ShareCenter DNS-320L Manuel utilisateur

Samsung
Samsung ES1642dc Instructions d'utilisation

Honeywell Home
Honeywell Home LTEM-PV Instructions de montage