Red Sea MAX NANO Manuel utilisateur

MAX®NANO
Installation and Operation Manual
Cabinet Installation Guide
Podium Installation Guide
AI Prime HD LED Manual

®
Red Sea MAX®NANO
Complete Plug & Play® Open Top Reef System
Installation and Operation Manual
PRINTING INSTRUCTIONS
To print only the Installation and
Operation Manual, print pages 2-25.

1
ENG
Red Sea MAX®NANO
Installation and Operation Manual
Complete Plug & Play® Open Top Reef System
Installation and Operation Manual

Red Sea MAX® NANO
2
MAX® NANO Installation & Operation Manual
Safety .....................................................................4
Location ..................................................................5
Unpacking the MAX® NANO ...................................6
Components ...........................................................7
Assembly ................................................................8
Installation of Rear Sump Components ........................9
Installation of Automatic Top-Off ..........................13
Installation of LED Modules ...........................................14
Operation of Pump Switch-box ..............................15
LED Set up and programming ................................16
Initial Fill .................................................................17
Operation of the Protein Skimmer ........................17
General Aquarium Maintenance ............................18
Trouble shooting ....................................................20
Warranty .................................................................22
Installation and Operation Manual

3
ENG
Congratulations on your purchase of the
Red Sea MAX® NANO complete reef system.
The Red Sea MAX® approach to the coral reef experience is to create
an environment that is specifically attuned to the needs of coral and
all inhabitants on an artificial reef. In the ocean coral reefs flourish
only where specific physical conditions prevail, such as sufficient light,
adequate current, stable temperature and water quality.
The Red Sea MAX® system provides the conditions that enable you to keep
a thriving, healthy reef in your own home.
We hope that you enjoy your MAX® and wish you happy reefing.
To benefit from product update information and special offers exclusive to
registered MAX® owners, please register your MAX® on-line at redseafish.com
Installation and Operation Manual

Red Sea MAX® NANO
4
1 Safety
Please read and follow all safety instructions.
a. Do not operate any appliance if it has a damaged cord or plug, if it is
malfunctioning, or if it is dropped or damaged in any manner.
If the external cable is damaged, it shall only be replaced by the
manufacturer.
b. To avoid the possibility of the appliance plug or receptacle getting
wet, position the aquarium stand and tank to one side of a wall
mounted receptacle to prevent water from dripping onto the
receptacle or plug. You should create a "drip loop" (Figure 1) for each
cord connecting an aquarium appliance to a receptacle. The "drip
loop" is that part of the cord below the level of the receptacle, or
the connector. Use an extension cord, if necessary, to prevent water
traveling along the cord and coming into contact with the receptacle.
If the plug or receptacle does get wet, DO NOT unplug the cord.
Disconnect the fuse or circuit breaker that supplies power to the
appliance. Then unplug the device and examine for presence of water
in the receptacle.
c. To avoid injury, do not contact moving parts.
d. Always unplug an appliance from an outlet when not in use, before
putting on or taking off parts, and before cleaning. Never pull the cord
itself to remove the plug from the outlet. Grasp the plug and pull to
disconnect.
e. Do not use an appliance for anything other than its intended use.
The use of attachments not recommended or sold by the appliance
manufacturer may cause an unsafe condition.
f. Do not install or store the appliance where it will be exposed to the
weather or to temperatures below freezing point.
g. Make sure an appliance mounted on a tank is securely installed before
operating it.
Read and observe all the important notices on the appliance.
NOTE: A cord rated for less amperes or watts than the appliance rating
may overheat. Care should be taken to arrange the cord so that
it cannot be tripped over or pulled accidentally.
DANGER: To avoid possible electric shock, special care should be
taken when handling a wet aquarium. For each of the
following situations, do not attempt repairs yourself; return
the appliance to an authorized service facility for service or
discard the appliance.
WARNING: To guard against injury, basic safety precautions should be
observed, including the following:
Drip Loop
Figure 1
Installation and Operation Manual

5
ENG
2 Location
The first step in setting up the MAX® NANO is to choose
a suitable location.
Electric Supply
Ensure that the electric power supply outlet used for the MAX® NANO
is correctly rated for the system (75W), plus whatever additional
equipment (such as a heater) you plan on adding. The power supply
outlet must be grounded and connected to a circuit protected by a
RCD/RCCB (residual current device or residual current circuit breaker)
also known as a GFI/GFCI (ground fault circuit interrupter).
Floor
The floor directly below the legs must be level and rated for a static
loading of at least 14kg/cm2 (200 lbs/square inch).
Room temperature
Site selection is important for correct temperature maintenance.
We recommend that you keep the ambient room temperature a
comfortable and stable 22°C / 72°F. Avoid placing the tank in front of
an air conditioner, heating vents or direct sunlight. A well ventilated
room with moderate light is the best place to position the aquarium.
Accessibility
•Back: Ensure that there is at least 10cm (4") of clearance behind the
MAX® to allow for sufficient air circulation for a chiller and general ease
of operation.
•Sides (Rear): Ensure that there is sufficient room (approximately
60cm/24”) between both sides of the aquarium and any adjacent walls
or furniture for access to the rear of the tank. This is required for the
regular maintenance of the surface skimmer, protein skimmer, flow
pump and filter media as well as installing/removing cables to the
Pump Switch-box.
General considerations
Ensure that the area surrounding the aquarium is waterproof and
consider moving away anything that water might damage or which may
be corroded by salt.
Installation and Operation Manual

Red Sea MAX® NANO
6
3 Unpacking the MAX®NANO System
Please read this section carefully before proceeding.
1. Remove the EVA mat and the protective packaging from around the
top of the tank.
2. Remove the components and any packaging materials that are packed
inside the aquarium.
3. Open the accessory box and remove all of the parts for later
assembly.
Removing the aquarium
With one person positioned at either side of the box, grasp the upper
rim of the aquarium and gently lift it out and place on the designated
surface.
CAUTION: The aquarium has a bare glass bottom. Before removing the
aquarium from the box prepare a smooth, soft, clean flat
surface that can hold its weight and place the EVA mat on it.
NOTE: Every precaution has been taken to ensure the safe arrival of the
MAX® NANO aquarium system, however before installing a new
glass aquarium it is advisable to inspect it for damage or leaks.
Place the aquarium in a suitable location and fill the tank and rear
sump to approximately 2.5cm (1”) below the top of the glass.
Leave the water standing for 15 minutes and inspect for leaks.
Syphon all of the water out before moving.
Approximate weights of Aquarium (empty)
Model Metric (kg) Imperial (lb)
NANO 23 51
Installation and Operation Manual

7
ENG
4 Components
MAX® NANO system main components
MAX® NANO type glass aquarium with integral rear sump 75L (20 gal)
MAX® NANO Cabinet (optional) Self-assembly
Pump Switch-box
LED – Prime HD™ light units 55W
Rear Sump Protein Skimmer NANO
Circulation pumps 1 x 950lph (240 gph)
Filter sponges 2
Carbon media with drawstring bag 100g
Rear Sump Screen
Automatic Top-Off
Installation and Operation Manual

Red Sea MAX® NANO
8
5 Assembly
Perform the assembly and installation of all of the components in the
order described below before adding the water to the system.
5.1 Cabinet assembly
Detailed instructions for the assembly of the MAX® NANO cabinet can be
found in the accompanying graphic manual.
The assembly of the cabinet requires the use of a regular crosshead
screwdriver. Do not use an electric screwdriver.
Adjustment of the Push-To-Open (PTO)
door opening unit.
Pressing the end of the PTO unit by 1.5mm
(
1/16”) will spring the shaft
forward by 5cm (2”) to the open position.
Pushing the PTO shaft back inside the cabinet will lock it in the closed
position.
After assembling the cabinet door, make sure that the PTO is in the closed
position and allow the soft close hinges to fully close the door. With the
door in the closed position press the door in the region of the PTO. The door
should spring open. If the door does not spring open adjust the position
of the PTO by rotating the front end of the shaft anticlockwise half a turn.
Repeat this adjustment until pressing the door causes the PTO to operate.
After assembly, place the cabinet in the desired location.
5.2 Pump Switch-box
Align the Pump Switch-box with the holes provided in the rear wall of the
aquarium and fix into position with the screws provided. Do not attach
the LED mounting arm or module at this time.
5.3 Placing Aquarium
Lifting the glass aquarium onto the cabinet will require 2 people. The top
of the cabinet is approximately 86cm (34”) from the floor. Ensure that
anyone lifting the aquarium is physically suitable for such an operation
and has been instructed in the correct methods of lifting heavy objects.
Aquarium must be lifted from the bottom.
Place the EVA mat on the top of the cabinet or other surface that will be
supporting the aquarium. The EVA mat is smaller than the aquarium. Place
the glass flush with the back of the mat and 3mm (1/8") from each of the
sides.
Before lifting aquarium, place the assembled cabinet in the final
operating position (see location above) and set the glass aquarium in
position on top.
The back and sides of the glass should be flush with the rear and side
edges of the top of the cabinet.
Once the aquarium is correctly aligned with the cabinet, check that the
cabinet has not moved. If necessary readjust the position of the cabinet.
NOTE: Left and Right designations in this manual are when looking
from the front of the Aquarium. NOTE: Do not plug the Switch-box power cable to your power outlet
until instructed to do so.
WARNING: If you are not experienced in the construction of self
assembly furniture, seek suitably qualified assistance.
Installation and Operation Manual
Table des matières
Autres manuels Red Sea Autre

Red Sea
Red Sea REEFER DLX 425 Manuel utilisateur

Red Sea
Red Sea MAX E Series Manuel utilisateur

Red Sea
Red Sea REEFER 250 Manuel utilisateur

Red Sea
Red Sea Complete Plug & Play MAX E-170 Manuel utilisateur

Red Sea
Red Sea Hydra 26 Manuel utilisateur

Red Sea
Red Sea MAX S-Series Manuel utilisateur

Red Sea
Red Sea ReefLED 50 Manuel utilisateur

Red Sea
Red Sea REEFER Series Manuel utilisateur

Red Sea
Red Sea Complete Plug & Play MAX E-170 Guide de démarrage rapide

Red Sea
Red Sea Referer 350 Manuel utilisateur