RainPoint ITV101P Manuel utilisateur

ITV101P
USER MANUAL
English Español
Email
seice@rainpointus.com
WhatsApp
+1 626-780-5952
Free Hotline
US: +1833-381-5659 (EN)
EU: +44 800-808-5337 (EN DE)
Save the user manual for future reference
If you have any questions, please contact us to get suppo

WARM TIPS
PLEASE READ BEFORE USING
FOR ANY PROBLEMS DURING USE, PLEASE CONTACT US:
Web: www.rainpointonline.com
Email: seice@rainpointus.com
WhatsApp: +1 626-780-5952
US Free Hotline(English):
+1 833-381-5659(MON-FRI 9:30 AM-5:30 PM PST)
EU Free Hotline(English Deutsch):
+44 800-808-5337(MON-FRI 9:00 AM-5:00 PM CET )
Don’t use the water timer when the temperature is below
37℉(3℃), and please store the timer indoors to avoid
potential freezing damage.
The lter traps di paicles, preventing them from
entering the timer and causing clogging. Please clean
the lter regularly and replace it if worn.
To ensure a longer lifespan, please use 2 new AA
alkaline batteries (not included). Don’t mix new and old
alkaline, standard (carbon-zinc), or rechargeable batteries.
Only use with clean cold water.
Please activate the water timer before rst use or after a
period of inactivity
(Refer to page 6: ACTIVATE THE TIMER BEFORE USE).

PRODUCT OVERVIEW
At A GLANCE
- 01 -
FILTER
HOSE TAP
CONNECTION
OK/MANUAL
BUTTON
OUTLET
BIG LCD
SCREEN
+/DELAY
BUTTON
DIAL
DIAL
BUTTON FUNCTION
OK /MANUAL
BUTTON
+ /DELAY BUTTON
Rotate the dial to set your watering
schedule.
Use "OK" to conrm the time. When the dial is
turned to "ON", press and hold "MANUAL" to
water manually.
Use "+" to adjust the time. When the dial is
turned to "ON", press and hold "DELAY" to
activate Rain Delay.
- 01 -

Waterproof
Min/Max Operating
Pressure
Max Flow Rate
Working Temperature
Power By
Thread
0.5bar-8bar (7.25 psi-116 psi)
10 Gal/Min (35L/Min)
37.4℉-122.4℉( 3℃-50℃ )
IP54
2 AA (1.5V) alkaline batteries (not included)
Watering Times
Per Day
1 to 3 times a day
(Up to 3 watering plans a day)
Watering Days Monday to Sunday OR Eve
2/3/4/5/6 days
NH(US) for 3/4" faucet / hose
BSP(EU) for 3/4" or 1" faucet / hose
SPECIFICATION
Watering Duration From 1 minute to 3 hours 59
minutes (4 hours)
Manual Watering Time
Rain Delay Time
1 minute to 8 hours, default 10 minutes
24h, 48h, 72h, default 24 hours
- 02 -

Eve _ Days
Next
Sta Time
P1/P2/P3
Low batte indicator
Flashing during watering
The selected day of the week
Inteal watering days
The time left to the next watering
The sta time of watering
Watering plans for one day
SET CLOCK
START TIME
HOW LONG
HOW OFTEN
VIEW SET
ON
Set your local current time
Set the sta watering time (Eve
watering plan has its own sta time)
Set watering duration from 1
minute to 3 hours 59 minutes.
(Eve watering plan has its own
watering duration)
Set watering frequency of the
week or eve few days
(3 watering plans share 1
watering frequency)
View all your settings of 3 plans
① Sta automatic watering
based on your programs.
② When the dial is in the ON
position, hold "+/DELAY"
button to enter delay mode.
OFF Turn o all watering programs
and shut o the valve.
DIAL POSITION FUNCTION
- 03 -
LCD ICON FUNCTION

PRODUCT INSTALLATION
INSTALLING THE BATTERIES
1. Remove the batte tray on the back of the timer.
2. Inse 2 new AA (1.5V) alkaline batteries (not included).
3. Put the batte tray back on the timer and press rmly to
make sure it is completely sealed.
BATTERY STATUS
Batte Status will be displayed as following:
Full Power Low Power
Note:
Note:
When the low batte indicator appears on display, the valve will close
automatically to avoid leakage. Please replace the batte in time in case of
interrupting the normal operation.
1. Install the batte tray securely after
installing the batte to ensure
waterproong.
2. When the timer is not used for a long
time, please remove the batteries and
dispose of them properly.
3. Replace batteries when the low batte
indicator appears on display. After
you done it, please remember to reset
your watering plans.
4. Don’t dispose of batteries in re.
Batteries may explode or leak.
5. To ensure a longer lifespan, please use
2 new AA alkaline batteries
(not included). Don’t mix new and old
alkaline, standard (carbon-zinc), or
rechargeable batteries.
- 04 -

INSTALLING THE TIMER
Inlet
Outlet
Tips: If the connection between the timer and the faucet or hose is
not tight or leaking, wrap more Teon Tape(thread seal tape) to make
them tight.
Note:
Please do not use tools, only install the timer by hand.
When expecting freezing temperatures, timers should be removed
from the hose faucet and stored indoors to avoid potential freeze
damage.
Please install the lter properly and keep it clean as follows.
1) Turn o the garden faucet.
2) Wrap Teon Tape around the faucet
threads.
3) Screw the timer to the garden faucet
and make the display as veical as
possible to the ground to prevent
rainwater from accumulating and
leaking into the interior.
4) Wrap Teon Tape around the threads
of the timer outlet.
5) Screw the garden hose to the timer
outlet.
6) Turn on the faucet after programming
the timer.
- 05 -

Please activate the device before using it for the rst time or after a
period of inactivity.
ACTIVATE THE TIMER BEFORE USE
Activation Steps:
1. Keep the garden faucet turned o.
2. Turn the timer dial to "ON".
3. Press and hold the "MANUAL" button for 3-5s to enter Manual
Watering Mode.
4. When the screen is ashing, press the "OK" button twice, and the
screen will stop ashing.
5. Wait about 5 seconds or until you hear a "click" and the valve in the
timer opens, then turn the dial to "OFF" to close the valve.
6. Repeat the step 2-5 for 3-5 times.
7. Test: Turn on the faucet a little bit, and then repeat the step 2-5 to
check if the water ow out or shut o as expected.
If yes, the timer valve is normal, please use it with condence!
If not, please repeat the above steps several times or contact
RAINPOINT suppo team immediately.
Note:
When testing, please keep away from the water timer outlet to avoid
being splashed and wet.
- 06 -

PROGRAMMING YOUR TIMER
SET CLOCKSTEP 1:
Tips:
1. Press and hold the "+" button can increase the time quickly.
2. When the setup of this STEP is nished, please turn the dial to save
the changes instead of press the "OK" button. If you press the "OK"
button after setting, it will return to the previous setting instead of
saving it.
1. Turn dial to "SET CLOCK".
2. " " ashing: Use the "+" button to select the day of the week,
then press "OK" to conrm.
3. " " ashing: Use the "+" button to set hour and press "OK" to
conrm.Press and hold the "OK" button to switch the time display in
12-hour or 24-hour mode.
·12-hour mode: with "AM" or "PM"
·24-hour mode: without "AM" or "PM"
4. " " ashing: Use the "+" button to set minute and press "OK" to
conrm.
5. Turn the dial clockwise to save the changes in this STEP and go to
next STEP.
- 07 -

1. Turn dial to "START TIME".
2. Use the "+" button to set the sta time and press the "OK" button
to conrm.(If you choose 12-hour mode, please note AM and PM)
3. After conrming this plan, press the "OK" button again to switch to the
next plan.
4. Turn the dial clockwise to save the changes in this STEP and go to
next STEP.
Tips:
1. Press and hold the "+" button can increase the time quickly.
2. If you want to turn o a ceain plan, please adjust the sta time
to "23 : xx" (24-hour mode) or "11 : xx" PM (12-hour mode) when
setting the plan. Then press the "+" button again, and "OFF" will
appear on the screen, indicating that the plan has been closed.
3. If you want to cancel the "OFF" plan, press the "+" button again on
the plan to set its sta time.
4. When the setup of this STEP is nished, please turn the dial to save
the changes instead of press the "OK" button. If you press the "OK"
button after setting, it will return to the previous setting instead of
saving it.
START TIMESTEP 2:
- 08 -
Autres manuels pour ITV101P
2
Table des matières
Autres manuels RainPoint Système d'irrigation
Manuels Système d'irrigation populaires d'autres marques

Hunter
Hunter Institutional Series Manuel utilisateur

Cellfast
Cellfast 52-305 Manuel utilisateur

Tyco Fire Product
Tyco Fire Product Star Galaxy SGQR Manuel utilisateur

Tyco Fire Product
Tyco Fire Product CENTRAL A Manuel utilisateur

Oral Care Technologies
Oral Care Technologies Hydro Floss Manuel utilisateur

Reliable
Reliable F1-300 Manuel utilisateur
















