Racal Instruments 1260 Manuel utilisateur

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Astronics / EADS / Racal 1260-18 at our website: Click HERE

1260 VXI
SWITCHING CARD
1260-18
HIGH DENSITY BASIC
SWITCH
PUBLICATION NO. 980673-040
RACAL INSTRUMENTS
Racal Instruments, Inc.
4 Goodyear St., Irvine, CA 92618-2002
Tel: (800) 722-3262, FAX: (949) 859-7309
Racal Instruments, Ltd.
480 Bath Road, Slough, Berkshire, SL1 6BE, United Kingdom
Tel: +44 (0) 8706 080134; FAX: +44 (0) 1753 791290
Racal Systems Electronique S.A.
18 Avenue Dutartre, 78150 LeChesnay, France
Tel: +33 (1) 3923 2222; FAX: +33 (1) 3923 2225
Racal Systems Elettronica s.r.l.
Strada 2-Palazzo C4, 20090 Milanofiori Assago, Milan, Italy
Tel: +39 (02) 5750 1796; FAX +39 (02) 5750 1828
Racal Elektronik System GmbH.
Frankenforster Strasse 21, 51427 Bergisch Gladbach, Germany
Tel:+49 2204 92220; FAX: +49 2204 21491
Racal Australia Pty. Ltd.
3 Powells Road, Brookvale, NSW 2100, Australia
Tel: +61 (2) 9936 7000, FAX: +61 (2) 9936 7036
Racal Electronics Pte. Ltd.
26 Ayer Rajah Crescent, 04-06/07 Ayer Rajah Industrial Estate, Singapore 0513.
Tel: +65 7792200, FAX: +65 7785400
Racal Instruments, Ltd.
Unit 5, 25F., Mega Trade Center, No 1, Mei Wan Road, Tsuen Wan, Hong Kong, PRC
Tel: +852 2405 5500, FAX: +852 2416 4335
http://www.racalinst.com
PUBLICATION DATE: June 28, 1999
Copyright 1999 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved.
This book or parts thereof may not be reproduced in any form without written permission of the publisher.

WARRANTY STATEMENT
All Racal Instruments, Inc. products are designed and manufactured to exacting standards and in full
conformance to Racal’s ISO 9001 procedures.
For the specific terms of your standard warranty, or optional extended warranty or service agreement, contact
your Racal customer service advisor. Please have the following information available to facilitate service.
1. Product serial number
2. Product model number
3. Your company and contact information
You may contact your customer service advisor by:
E-Mail: [email protected]
Telephone: +1 800 722 3262 (USA)
+44(0) 8706 080134 (UK)
+852 2405 5500 (Hong Kong)
Fax: +1 949 859 7309 (USA)
+44(0) 1628 662017 (UK)
+852 2416 4335 (Hong Kong)
RETURN of PRODUCT
Authorization is required from Racal Instruments before you send us your product for service or calibration. Call
your nearest Racal Instruments support facility. A list is located on the last page of this manual. If you are
unsure where to call, contact Racal Instruments, Inc. Customer Support Department in Irvine, California, USA at
1-800-722-3262 or 1-949-859-8999 or via fax at 1-949-859-7139. We can be reached at:
PROPRIETARY NOTICE
This document and the technical data herein disclosed, are proprietary to Racal Instruments, and shall not,
without express written permission of Racal Instruments, be used, in whole or in part to solicit quotations from a
competitive source or used for manufacture by anyone other than Racal Instruments. The information herein has
been developed at private expense, and may only be used for operation and maintenance reference purposes or
for purposes of engineering evaluation and incorporation into technical specifications and other documents which
specify procurement of products from Racal Instruments.

FOR YOUR SAFETY
Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully the
WARNINGS and CAUTION notices.
This equipment contains voltage hazardous to human life and safety, and is capable of inflicting
personal injury.
If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure the
common connector is connected to the neutral (earth pole) of the power supply.
Before operating the unit, ensure the conductor (green wire) is connected to the ground (earth)
conductor of the power outlet. Do not use a two-conductor extension cord or a three-prong/two-
prong adapter. This will defeat the protective feature of the third conductor in the power cord.
Maintenance and calibration procedures sometimes call for operation of the unit with power applied
and protective covers removed. Read the procedures and heed warnings to avoid “live” circuit
points.
Before operating this instrument:
1. Ensure the instrument is configured to operate on the voltage at the power source. See
Installation Section.
2. Ensure the proper fuse is in place for the power source to operate.
3. Ensure all other devices connected to or in proximity to this instrument are properly grounded or
connected to the protective third-wire earth ground.
If the instrument:
-fails to operate satisfactorily
-shows visible damage
-has been stored under unfavorable conditions
-has sustained stress
Do not operate until performance is checked by qualified personnel.

This page was left intentionally blank.

Amendment Page 6/98 1
NOTE FOR SYSTEMS WITH 1260-OPT 01T
The “Module-Specific Syntax” section of this manual shows the command syntax for the
1260-01S Smart Card. If you are using the newer 1260-01T Smart Card, the commands
will NOT work as shown.
Consult the 1260-01T Manual for a description of the commands that may be used with the
1260-01T Smart Card.
The channel numbers described in this manual are valid for the 1260-01T. The channel
numbers continue to be used for the 1260-01T.
The syntax of the commands that use channel numbers has changed for those cards
controlled by the 1260-01T.
The new syntax used to close a channel is:
CLOSE (@ <module address> ( <channel> ) )
For example, for a relay module whose <module address> is set to 7, closing <channel> 0
is performed with the command:
CLOSE (@7 (0))
Using the older 1260-01S, the command would be (as shown in this manual):
CLOSE 7.0
Many other command syntax differences exist. Please consult chapter 2 of the 1260-01T
manual for a description of the commands that are available for the 1260-01T.

Control Information for the 1260-18
The following information describes the control-register-to-relay-channel mapping for a 1260-18 Relay Module.
This information may be used to control a 1260-18 when using a 1260-01T in the register-based mode of
operation.
Each relay on this module is controlled by setting or clearing a single bit within a Control Register. Control
Registers on the module operate 8 channels simultaneously. There are eight control bits per Control Register.
Setting the bit to a 1 closes the relay; setting the bit to a 0 opens the relay.
The table below shows the mapping from logical channels to control bits. The logical channels are used when
operating the relay module in message-based mode. The control bits within the Control Registers are used to
operate the module in register-based mode.
Each Control Register is located 2 addresses from the previous Control Register. That is, each Control
Register is located at an odd address. This is shown in Table 2-2 of the 1260-01T manual. Control Register 0
is located at the “Base A24 Address” for the module. Consult the “Register-Based Operation” Section of
Chapter 2 of the 1260-01T manual for a description of calculating control register addresses
Channel Control Register Control Bit
000
101
202
303
404
505
606
707
810
911
10 1 2
11 1 3
12 1 4
13 1 5
14 1 6
15 1 7
16 2 0
17 2 1
18 2 2
19 2 3
20 2 4
21 2 5
22 2 6
23 2 7
24 3 0
25 3 1
26 3 2
27 3 3
28 3 4
29 3 5
30 3 6
31 3 7
32 4 0
33 4 1
34 4 2
35 4 3
36 4 4
37 4 5
38 4 6
39 4 7
40 5 0
41 5 1

Channel Control Register Control Bit
42 5 2
43 5 3
44 5 4
45 5 5
46 5 6
47 5 7
48 6 0
49 6 1
50 6 2
51 6 3
52 6 4
53 6 5
54 6 6
55 6 7
56 7 0
57 7 1
58 7 2
59 7 3
60 7 4
61 7 5
62 7 6
63 7 7
64 8 0
65 8 1
66 8 2
67 8 3
68 8 4
69 8 5
70 8 6
71 8 7
72 9 0
73 9 1
74 9 2
75 9 3
76 9 4
77 9 5
78 9 6
79 9 7
80 10 0
81 10 1
82 10 2
83 10 3
84 10 4
85 10 5
86 10 6
87 10 7
88 11 0
89 11 1
90 11 2
91 11 3
92 11 4
93 11 5
94 11 6
95 11 7
96 12 0
97 12 1
98 12 2
99 12 3
100 12 4
101 12 5
102 12 6
103 12 7
104 13 0
105 13 1
106 13 2

Channel Control Register Control Bit
107 13 3
108 13 4
109 13 5
110 13 6
111 13 7
112 14 0
113 14 1
114 14 2
115 14 3
116 14 4
117 14 5
118 14 6
119 14 7
120 15 0
121 15 1
122 15 2
123 15 3
124 15 4
125 15 5
126 15 6
127 15 7
128 16 0
129 16 1
130 16 2
131 16 3
132 16 4
133 16 5
134 16 6
135 16 7
136 17 0
137 17 1
138 17 2
139 17 3
140 17 4
141 17 5
142 17 6
143 17 7
144 18 0
145 18 1
146 18 2
147 18 3
148 18 4
149 18 5
150 18 6
151 18 7
152* 19 0
153* 19 1
154* 19 2
155* 19 3
156* 19 4
157* 19 5
158* 19 6
159* 19 7
*These control bits exist, but the relays are not normally populated on the module.

User Manual 1260-18
i
Table of Contents
Chapter 1
MODULE SPECIFICATION..........................................................................................................1-1
Module Specification................................................................................................................. 1-1
Specifications............................................................................................................................1-2
Ordering Information................................................................................................................. 1-3
Safety........................................................................................................................................1-4
Product Support........................................................................................................................ 1-4
Chapter 2
INSTALLATION INSTRUCTIONS ................................................................................................ 2-1
Unpacking and Inspection......................................................................................................... 2-1
Reshipment Instructions............................................................................................................ 2-1
Option 01 Installation ................................................................................................................2-2
Module Installation ....................................................................................................................2-2
Chapter 3
MODULE OPERATION ................................................................................................................3-1
Module Configuration................................................................................................................ 3-1
Front Panel Connectors......................................................................................................... 3-1
Mating Connectors.............................................................................................................3-1
1260-18 Module Specific Syntax............................................................................................ 3-2
1260-18 Relay Descriptors................................................................................................. 3-2
1260-18 INCL Command ...................................................................................................3-4
CLOSE Command .............................................................................................................3-6
OPEN Command ...............................................................................................................3-7
EXCL Command................................................................................................................ 3-7
PDATAOUT and PSETUP Module Identification................................................................3-8
PDATAOUT Command......................................................................................................3-9
PSETUP Command......................................................................................................... 3-10
Autres manuels pour 1260
5
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Racal Instruments Changer

Racal Instruments
Racal Instruments X Series Manuel utilisateur

Racal Instruments
Racal Instruments 1260-82 Manuel utilisateur

Racal Instruments
Racal Instruments 1260-37 Manuel utilisateur

Racal Instruments
Racal Instruments 1256E Manuel utilisateur

Racal Instruments
Racal Instruments 1260-X121 Manuel utilisateur

Racal Instruments
Racal Instruments 1256 Manuel utilisateur

Racal Instruments
Racal Instruments 1260-22 Manuel utilisateur

Racal Instruments
Racal Instruments 1260 Manuel utilisateur

Racal Instruments
Racal Instruments 1260-100 Manuel utilisateur

















