Quantum 3U Manuel utilisateur

LTO-5 Full-Height Tape Drive
Contents
Connecting the Drive Interface and Power
Cables .....................................................2
Installing a Second Tape Drive or
Replacing a Tape Drive ...........................3
Preinstallation Requirements .............3
Installation Procedure ........................4
Installing the 3U Rackmount Enclosure in
a Rack ...................................................10
Tools Required ..................................10
Installation Requirements ................10
Installing the 3U Enclosure ..............11
Class A Device Declarations..................15
3U Rackmount Enclosure
Quick Start Guide
The 3U Rackmount enclosure is provided with one or of the following
supported tape drives already installed:
• LTO-5 Full-Height, SAS model TC-L53FN-AR
You can upgrade a single-drive enclosure to the two-drive configuration by
installing a second tape drive using any supported model of the same type
interface.
This guide references the instructions for installing the 3U Rackmount
enclosure in an equipment rack, and provides the procedures for:
• Connecting the drive interface and power cables
• Installing a second tape drive into the 3U Rackmount enclosure

2Connecting the Drive Interface and Power Cables
LTO-5 Full-Height Tape Drive
Power Requirements Power requirements for the 3U Rackmount enclosure are as follows:
• 100 to 240 Volts AC/2 to 4 Amps
• 47 to 63 Hz
Connecting the Drive Interface and Power Cables
1Shut down and turn off the host server system.
2Turn off all attached accessory devices, such as printers and other SCSI devices.
3On the back panel of a serial-attached SCSI (SAS) 3U Rackmount enclosure (see
Figure 1):
aConnect one end of the supplied external SAS interface cable to the external SAS
interface connector on the same side of the enclosure as the installed tape drive
(see Figure 1).
bConnect the other end of the external SAS interface cable to the SAS connector
on the host server.
Figure 1 SAS Interface
Connectors
SAS connectors
4Connect the supplied AC power cable to the AC power connector on the back panel
of the 3U Rackmount enclosure (see Figure 2).
Figure 2 AC Power Connector
AC power connector

Installing a Second Tape Drive or Replacing a Tape Drive 3
LTO-5 Full-Height Tape Drive
5Connect the other end of the AC power cable to the rack/facility AC power
receptacle.
6Press the master AC power switch on the front of the 3U Rackmount enclosure to
apply power to the enclosure and illuminate the power LED (see Figure 3).
Figure 3 Power Button
Power switch
Power LED
7Turn on all attached accessory devices, such as printers and other SCSI devices that
you turned off at step 2 of this procedure.
8Turn on and restart the host server.
Installing a Second Tape Drive or Replacing a Tape Drive
Follow these instructions to install a second tape drive or to replace a tape drive after it
has been removed.
Caution: Before installing a second tape drive, you must turn off the 3U Rackmount
enclosure and disconnect it from its AC power source.
Preinstallation
Requirements
Before installing a second tape drive in the 3U Rackmount enclosure, make sure you
have the following required tools and parts:
To o l s #2 Phillips screw driver
Parts • A supported model tape drive
• SAS cable depending on the tape drive type

4Installing a Second Tape Drive or Replacing a Tape Drive
LTO-5 Full-Height Tape Drive
Installation Procedure The installation procedure is divided into the following major sections:
Note: The 3U rackmount enclosure is designed for full-height tape drives, however,
half-height tape drives can also be installed. Refer to the tape drive
documentation for information on installation.
•Removing the Top Panel
•Adding a Second Tape Drive
•Replacing a Tape Drive:
•Connecting the Tape Drive Cables
•Closing the Top Panel
Removing the Top Panel
To remove the top panel:
1Press the drive power switch on the front panel of the 3U Rackmount enclosure to
turn off the drive power.
2Disconnect the AC power cable from the AC power connector on the back panel of
the 3U Rackmount enclosure.
3Remove the 3U Rackmount enclosure from the equipment rack and place it on a
clean, stable, flat surface.
4Open the top access panel (see Figure 4):
Figure 4 Top Access Panel
Top panel
Adding a Second Tape Drive
Note: If you are replacing a tape drive, refer to Replacing a Tape Drive: on page 6.
To add a second tape drive:
1Remove the shipping screw from the drive blank next to the thumbscrew.

Installing a Second Tape Drive or Replacing a Tape Drive 5
LTO-5 Full-Height Tape Drive
2Loosen the thumbscrew.
3Remove the drive tray (see Figure 5):
aPush the drive tray toward the rear of the 3U enclosure.
bPull the drive tray up and out at an angle.
Figure 5 Removing the Drive
Blank
Drive tray Drive tray
Drive blanks Drive blanks
4Remove the drive blanks from the front of the drive tray.
5Position the tape drive in the drive tray and align mounting holes with the holes in
the drive tray.
Caution: If you are installing a half-height tape drive, using screws other than
the Phillips screws labeled as General Mounting Screws can damage
the tape drive.
Do not use screws other than the General Mounting Screws to secure
the internal LTO-5 Half-Height Tape Drive.
6Secure the drive using two screws on each side of the tape drive.
7Install the tape drive tray into the 3U enclosure (see Figure 6):
aPlace the drive tray in the enclosure at an angle and then lay it flat.
bSlide the drive toward the front of the enclosure.
Note: Ensure that the cut outs on the drive tray line up with the tabs on the
enclosure.

6Installing a Second Tape Drive or Replacing a Tape Drive
LTO-5 Full-Height Tape Drive
Figure 6 Installing the Tape
Drive
8Secure the tape drive tray by tightening the thumbscrew.
Continue with Connecting the Tape Drive Cables on page 8.
Replacing a Tape Drive:
To replace a tape drive:
1Remove the tape drive (see Figure 7):
aDisconnect all cables from the tape drive.
aPush the drive tray toward the rear of the 3U enclosure.
bPull the drive tray up and out at an angle.

Installing a Second Tape Drive or Replacing a Tape Drive 7
LTO-5 Full-Height Tape Drive
Figure 7 Removing the Tape
Drive
2Remove the screws securing the mounting drive tray to the tape drive.
3Remove the failed tape drive from the drive tray.
4Position the new tape drive in the drive tray and align mounting holes with the holes
in the drive tray.
Caution: If you are installing a half-height tape drive, using screws other than
the Phillips screws labeled as General Mounting Screws can damage
the tape drive.
Do not use screws other than the General Mounting Screws to secure
the internal LTO-5 Half-Height Tape Drive.
5Secure the drive using two screws on each side of the tape drive.
6Install the tape drive tray into the 3U enclosure (see Figure 8):
aPlace the drive tray in the enclosure at an angle and then lay it flat.
bSlide the drive toward the front of the enclosure.
Note: Ensure that the cut outs on the drive tray line up with the tabs on the
enclosure.

8Installing a Second Tape Drive or Replacing a Tape Drive
LTO-5 Full-Height Tape Drive
Figure 8 Installing the New
Ta p e D r i v e
7Secure the tape drive tray by tightening the thumbscrew.
Continue with Connecting the Tape Drive Cables on page 8.
Connecting the Tape Drive Cables
To connect the tape drive cables:
1Connect the following cables to the back of the tape drive (see Figure 9).
aConnect the SAS cable to the tape drive SAS connector.
bConnect a power cable to the SAS cable.
Figure 9 Connecting the SAS
and Power Cables
SAS cable
Power cable

Installing a Second Tape Drive or Replacing a Tape Drive 9
LTO-5 Full-Height Tape Drive
Closing the Top Panel
To close the top panel (see Figure 10):
1Close the top access panel.
2Install the 3U enclosure back into the rack.
3Connect the AC power connector on the back panel of the 3U Rackmount enclosure.
4Press the drive power switch on the front panel of the 3U Rackmount enclosure to
turn on the drive power.
Figure 10 Closing the Top
Access Panel
Top panel

10 Installing the 3U Rackmount Enclosure in a Rack
LTO-5 Full-Height Tape Drive
Installing the 3U Rackmount Enclosure in a Rack
The rack rails supplied with the 3U rackmount enclosure can be used to install the unit in
racks that have round, square, or threaded holes in the vertical mounting bars.
The kit contains the following items:
• A template to mark the rack for proper alignment of rack-mounting brackets.
• A cable management system consisting of a cable reel and cable rack bracket.
• A pair of spring-loaded rails.
Tools Required If you are installing the tape enclosure in a rack with unmarked holes in the vertical
mounting bars the following items will make the rack installation easier:
•Pencil
• #2 Phillips screwdriver to install the cable management system.
• Two M6 x 1.0-12L Phillips screws that came with your rack.
Installation
Requirements
When installing the enclosure in a rack:
• Start at the bottom of the rack, or at the top of a previously mounted component,
and work upward.
• If possible, install the heaviest components at the bottom and lighter ones toward
the top of the rack.
• Make sure that the rack-mounting rails are level from front to back.
WARNING: To reduce the risk of personal injury or equipment damage, be sure that:
1. The rack leveling jacks are extended to the floor. 2. The full weight of
the rack rests on the leveling jacks. 3. The stabilizing feet are attached to
the rack if it is a single rack installation. 4. The racks are coupled in
multiple rack installations. 5. Only one component is extended at a time.
6. A rack may become unstable if more than one component is extended
for any reason.
Before you begin
If you are installing the 3U rackmount enclosure in a rack with unmarked holes in the
vertical mounting bars, identify and mark the correct mounting holes in the rack before
you begin rail installation.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Quantum Enceinte