Qeedji SMT210 Manuel utilisateur

User Manual
SMT210
4.11.11 001A
1

Legal Notice
User Manual SMT210 4.11.11 (001A_en)
© 2019 INNESSA
Rights and Responsibilities
All rights reserved. No part of this manual may be reproduced in any form or by any means whatsoever without the written permission of the publisher. The products
and services mentioned in this document may be trademarks and/or trademarks of their respective owners. The publisher and the author do not pretend to these
brands.
Although every precaution has been taken in the preparation of this document, the publisher and the author assumes no responsibility for errors or omissions, or for
damages resulting from the use of the information contained in this document or the use of programs and source code who can accompany it. Under no circumstances
can the publisher and the author be held responsible for any loss of profits or any other commercial prejudice caused or that would have been caused directly or
indirectly by this document.
Product information
The conception and specifications of the product may change without prior notice, and this applies to hardware, embedded software and this guide. Consumable items
accessories may slightly differ than herein described as Qeedji is depending on the evolutions of its suppliers. This document contains confidential information; it can’t
be disclosed to any third parties without prior written authorization of INNES.
Safety instructions
Please read carefully the following instructions before switching the product on: - WARNING! Correct fitting and installation is of the utmost importance. Incorrect fitting
and/or installation may result in personal injury or loss. Qeedji disclaims all liability, of whatever kind, if the product is assembled, fitted and/or installed in an incorrect
manner. - Do not use the product near a water supply. - Do not pour anything on the product, like flammable liquids or material. - Do not expose the product to direct
sun, near a heating source or a dust nor vibrations. - Do not obstruct holes, to be sure that air flows freely around the product. - Switch off the product during a storm. -
Do not open the product in any circumstances.
Guarantee terms
Qeedji products are eligible for a warranty to cover genuine manufacturing defect for 3 years. Product failure occurring as the result of factors that do not constitute
genuine manufacturing defect are not covered under the terms of the warranty and any repairs of this nature would be chargeable. For example: Inappropriate
maintenance action, a non-authorized modification, a not specified environment utilization (see ‘Safety instructions’), or if the product has been damaged after an
impact, a fall, a bad manipulation or a storm consequence, an insufficient protection against heat, moisture or frost. This warranty is not transferrable. In addition, any
repairs carried out by non-authorized personnel will invalidate the warranty.
WEEE Directive
This symbol means that your end of life equipment must not be disposed of with household waste but must be deposited at a collection point for waste electrical and
electronic equipment or to your reseller. This will benefit the environment. In this context, a system for collecting and recycling has been implemented by the European
Union
2

1.1 Introduction
This manual explains how to setup your device SMT210.
Recommendations and warnings
This device is designed to be used inside a building.
This device is intended to work with the supplied power supply unit. This power supply unit must be connected to a mains socket conforming to standard NF C 15-100. If
the AC power cable is damaged, it must be replaced. It is possible to order a replacement mains unit by sending a request to the email address [email protected].
This device is a Class A device. In a residential environment this device may cause radio interference. In this case, the user is asked to take appropriate measures.
When powering the unit from a PoE source, this PoE source must be "Limited Power Source" as defined in EN60950-1: 2006.
Content of the package
Items Functions
Device SMT210 with Gekkota embedded
1 power supply unit 12V Power Supply unit with cable of 1.2m
1 label PSN (Product Serial Number) on the packaging and on the device
4

1.2 Getting started with the device
Front face and side face
1 RFID tag sensor
2 Left side LED
3 Right side LED
4 Built-in speaker
5 Touch screen
Bottom face
6 Power supply connector
7 Power supply red LED
8 Status green LED
9 Jack 3,5 mm GPIO connector
10 RJ45 LAN PoE connector
11 Phoenix GPIO connector
12 SD card connector
13 SIM card (WWAN option) connector
14 USB2 2.0 connector
15 USB1 2.0 connector
16 WWAN antenna location
1
2
3
4
5
ST
PW
DC IN IR LAN
PoE
I/O
SD CARD
SIM
USB2 USB1
USB
CLIENT
6
7
8
9
10
11
12
13
14
15
16
5

Device fixture
200 mm
258 mm
176 mm
100 mm
6 mm ≤ Ø ≤ 8 mm
Ø ≤ 4 mm
34 mm
Device dimensions
258 mm
176 mm
35 mm
6

Labelling
The model of the device, the power supply characteristics, the serial number (PSN) and the MAC address are written on a label which is stuck on the case. Some
additional tags may be present in case of built-in options.
☛ The serial number of the device can be requested in case of technical support.
Model:
00:1C :E6:02:01:A9
5A rue Pierre Joseph C olin
35000 RENNES
12V DC
MAC :
830mA
www.qeedji.tech
Input:
SMT210
FR ANC E
PSN00434-01043 CD9
www.qeedji.tech
3 7 0 0 5 6 8 1 0 4 5 2 9
EAN
MODEL
SMT210B
7

Device start-up step
Testcard
At the factory, the device content set by default is the Test Card . The chart displays important information to assist in the device configuration:
Disable the Test Card by using the WebUI.
Step 1 (T0=0s)
Device start-up initialisation
Step 2 (T~21s)
Device start-up finalisation
This phase duration is depending on some variable values
(like NTP), some network access duration or some data
checking (check-disk)
Step 3 (T~1min)
Nominal mode
During this step, the device has to play the content.
When firmware upgrade process occured, in
case DNS valid & NTP server inactive, it takes
~6min.
>
8

1.4 Connectors
Power supply connector (12VDC-1.2A)
+
ST
PW
DC IN
LAN connector
Ethernet RJ-45. 10/100 BaseT. It is recommended to use schielded calbe.
IR LAN
PoE
Jack 3.5 mm connector (GPIO4)
321
IR LAN
PoE
N° Name Write/Read Control
1 Voltage reference 3.3V
2 GPIO4 IN ou OUT CPU/GPIO4
3 Ground
GPIO4 Electrical features
Vin min Vin max VOH min VOH max IOH max VOL max IOL max VIH min VIL max
GPIO4 -0.5V 3.8V 3.1V (-20 µA) 5V -100µA 0.6V (2mA) 5mA 2.35V 0.8V
The pin 3.3V must not be used as a power supply, but rather for voltage reference. A fuse (350mA @ 20°C) allows to cut the power in case current is more than 350mA.
Then the fuse can be manually re-armed. During board (re)starting, the defaut level for GPIO4 is 3.3V
The GPIO4 has:
one 4.7 KOhms pull-up to 3.3V and
one 182 KOhms pull-down to 0V
Principle schematics of several use case
Three wires input configuration for GPIO4:
Two wires configuration for GPIO4:
Output configuration for GPIO4:
3.3V
CPU/GPIO4
SMT210
Switch
Input
2 (Jack)
3 (Jack)
1 (Jack)
PERIPHERAL
CPU/GPIO4
SMT210
Switch or dry loop
Input
2 (Jack)
3 (Jack)
PERIPHERAL
9

Jack 3,5 mm GPIO4 configuration
The GPIO configuration des GPIOs can be realized by editing some user preferences in the device configuration Web interface or thanks to a configuration script.
How to configure the Jack 3.5 mm connector:
//Set Jack 3.5 mode infrared
if (aDirection == "disable")
{
Services.prefs.setBoolPref("system.connector.jack35_1.1.io.uart_1.enabled", true);
}
else //Set Jack 3.5 mode GPIO
{
Services.prefs.setBoolPref("system.connector.jack35_1.1.io.uart_1.enabled", false);
}
// Set the Jack 3.5 direction : input or output
if (aDirection == "out")
{
Services.prefs.setBoolPref("innes.app-profile.gpio-input.jack35-gpio_1.jack35_1.*.authorized", false);
Services.prefs.setBoolPref("innes.app-profile.gpio-output.jack35-gpio_1.jack35_1.*.authorized", true);
Services.prefs.setBoolPref("system.connector.jack35_1.1.io.jack35-gpio_1.enabled", true);
}
else if (aDirection == "in")
{
Services.prefs.setBoolPref("innes.app-profile.gpio-input.jack35-gpio_1.jack35_1.*.authorized", true);
Services.prefs.setBoolPref("innes.app-profile.gpio-output.jack35-gpio_1.jack35_1.*.authorized", false);
Services.prefs.setBoolPref("system.connector.jack35_1.1.io.jack35-gpio_1.enabled", true);
}
else if (aDirection == "disable")
{
Services.prefs.setBoolPref("innes.app-profile.gpio-input.jack35-gpio_1.jack35_1.*.authorized", false);
Services.prefs.setBoolPref("innes.app-profile.gpio-output.jack35-gpio_1.jack35_1.*.authorized", false);
Services.prefs.setBoolPref("system.connector.jack35_1.1.io.jack35-gpio_1.enabled", false);
}
Phoenix connector
The Phoenix connector has 2 functions:
the capability to drive with the GPIO1 a internal relay, allowing for example to open or close a electric door,
the capability to drive a peripheral or get the state of another peripheral thank to the GPIO2 and GPIO3.
I/O
SD CARD
SIM
12345
1
2
3
4
5
PIN N° Name Write/Read Driving
1 Internal relay PIN1 OUT CPU/GPIO1
2 Internal relay PIN2 OUT CPU/GPIO1
3 GPIO2 IN or OUT CPU/GPIO2
4 GPIO3 IN or OUT CPU/GPIO3
5 Ground
In case purchasing a male connector suitable for the peripheral, contact the provider WURTH and order the reference: 691 361 100 005
GPIO2/GPIO3 Electrical features
Vin min Vin max VOH min VOH max IOH max VOL max IOL max VIH min VIL max
GPIO2 -0.5V 6.5V 5V 0.4V 10mA 1.17V 0.63V
GPIO3 -0.5V 6.5V 5V 0.4V 10mA 1.17V 0.63V
CPU/GPIO4
SMT210
Logic gate, transistor or opto-coupler
Output
Power supply
+-
2 (Jack)
3 (Jack)
PERIPHERAL
10
Autres manuels pour SMT210
2
Table des matières
Autres manuels Qeedji Lecteur multimédia