Pyronix EURO mini Manuel utilisateur

EN50131-3:2009
EN50131-1:2006+A1:2009
PD6662:2010
Security Grade 2x
Environmental Class II
Software Version >2.1
User Manual
for the EURO mini
RINS1209-6

EURO mini User Guide
Page: 2
1. Contents Page
1. Contents Page ...............................................................................2
2. Introduction ..................................................................................3
2.1 Keypad Operation......................................................................3
2.2 Proximity Tags..........................................................................4
2.3 LED Indication ..........................................................................4
3. Setting/Unsetting Your EURO mini....................................................5
3.1 Before you set your system: .......................................................5
3.2 Setting Your System..................................................................5
3.3 If Unable to Set:
......................................................................5
3.4 Faults When Leaving the building: ...............................................6
3.5 Unsetting Your System...............................................................6
3.6 Intelligent Set...........................................................................7
3.7 Silencing Alarms .......................................................................7
3.8 Part Setting..............................................................................7
3.9 Simple Setting..........................................................................8
3.10 Setting With Faults ..................................................................8
4. Useful Features..............................................................................9
4.1 The Chime Facility.....................................................................9
4.2 Omitting An Input .....................................................................9
4.3 Keypad Hold-Up...................................................................... 10
5. Master Manager Menu................................................................... 11
5.1 Set Date & Time...................................................................... 12
5.2 Change Codes......................................................................... 12
5.3 Review Logs ........................................................................... 13
5.4 Walk Test............................................................................... 14
5.5 Siren Test .............................................................................. 14
5.6 Allow Engineer Menu? .............................................................. 14
6. Programming Appendix................................................................. 15
NOTE: The specification of EURO mini may vary between different software
version, and some facilities in the manual may not be available. Check with
your installer for full details. This equipment may be used in systems
installed to a lower grade, which will be agreed with your installation
company. There are no user serviceable parts contained in this product.
(RINS1209) Issue 6

EURO
mini
User Guide
Page: 3
2. Introduction
2.1 Keypad Operation
Using your EURO mini Alarm System just couldn’t be easier!
This is the Keypad from where you control your Alarm System*
The LCD display guides you through user
menus and gives you any important messages
regarding the status of the system.
The 10-digit numeric keypad is where you use
your PIN code.
The A B C D keys allow you to choose which
level of security you wish to apply when you
leave the building, or to part-set the system.
To set your system really simply just press
‘YES’ and then press the Area Key required (If
enabled by your engineer).
MAINS FAIL
EURO mini
NOTE: For your security, the keypad becomes disabled for 90 seconds
after 30 incorrect key-presses. It will subsequently be disabled again
after 7 further incorrect key-presses. Once a correct code has been
registered, the keypad is returned to normal operation.
*Please note that Keypad design may differ from that shown.

EURO
mini
User Guide
Page: 4
2.2 Proximity Tags
Your EURO mini system may have been enabled
for use with proximity tokens, or ‘Tags’.*
You can use your Tag in place of a pin code for
all operations of the alarm system, i.e. setting,
unsetting, and entering the Manager and User
Menus.
2.3 LED Indication
All keypads and readers have LEDs to clearly indicate what is
happening.
The ‘Alert’ (orange) LED will flash if there is information to display for
you. Enter your code to see the information. After a code has been
entered, one of the following lamps will light: Alarm, tamper or fault.
The relevant detail of the problem will be shown on the display. To
clear the display, press the ‘Yes’ key (or the display will clear
automatically after 3 minutes.)
The ‘Alarm’ (red) LED will flash after code entry if an alarm occurs.
The ‘Tamper’ (red) LED will flash after code entry if the wiring or
equipment is tampered with.
The ‘Fault’ (orange) LED will light after code entry to indicate if a
technical fault occurs.
The ‘Unset’ (green) LED will light for 5 seconds after unsetting any
part of the system. It will also light during the setting procedure, going
off once set.

EURO
mini
User Guide
Page: 5
3. Setting/Unsetting Your EURO mini
3.1 Before you set your system:
Close Windows
Close Doors
Exclude Pets & People
If you are leaving the building, go to your
keypad and key in your PIN code or present
your Tag. Select the level of security you wish
to set by pressing the ABCD keys.
3.2 Setting Your System
Enter your code. Exit tone Starts
Leave by the agreed Exit Route, within
the designated time
Close and Lock the Final Exit Door.
Exit tone will cease
EURO mini is now SET
3.3
If Unable to Set:
If when you key in your PIN code a warning
tone sounds and the
unset
LED comes on,
the keypad display will show the nature of
the problem.
The tone will cease after about 10
seconds.
Press the
‘NO’
key
The system will remain unset, so you
can resolve the problem.
For example, you may have left a door
open, if so, close the door.
Now commence the setting procedure again.
EURO mini
SETTING [009]
House
If your exit is timed, you will
see the screen above. If you
use a final-door-set, you will
see the screen below.
Leave via
Exit Route
UNABLE TO SET
BACK DOOR

EURO
mini
User Guide
Page: 6
3.4 Faults When Leaving the building:
If when you have closed the final exit door,
the exit tone continues to sound an
interrupted tone…
“beep – beep – beep – “
You have probably left a protected door on
the exit route open.
Return to the keypad and note the
message on the display.
Stop the setting procedure with your PIN code or your Tag.
Close the open door
Now commence the setting procedure again (see page 5).
3.5 Unsetting Your System
To enter the building you
must
use the
agreed entry route and go straight to the
keypad.
Entry tone will be sounding
“beep – beep – beep –“
Key in your PIN code or present your
Tag.
Entry tone will cease
To indicate that the system has unset, the
unset LED will illuminate for five seconds.
EURO mini is now UNSET
EXIT VIA
HALLWAY
ENTRY [020]
TIME
ENTRY [010]
TIME **

EURO
mini
User Guide
Page: 7
3.6 Intelligent Set
If you wish to set
EURO
mini
and stay in the building (eg set part of
the alarm at night), the
EURO
mini
’s intelligent operating system
will realise which level of security you require and will set only part
of the system
If intelligent set is not installed on your system, you may part set
the system as described below.
To Intelligent Set your
EURO
mini
go to the keypad and enter
your PIN code or present your Tag.
By default, EURO
mini
will ask if you want to set area
B
, this
can be overridden if required by pressing the
ABCD
keys.
Press ‘
YES
’
Exit tone will start
Area
B
will now start setting.
If you now open and go through your final exit door,
EURO
mini
will detect you and will now ‘quick set’ area
A
.
EURO mini is now SET
NOTE: This feature must be enabled by your installation company.
3.7 Silencing Alarms
If an Alarm tone sounds, the Alert LED will flash:
Just key in your PIN code or present your Tag.
The Alarm will stop sounding
The display will indicate the problem.
Press the
‘YES’
Key
If the ‘Alert’ LED indication remains lit, there is additional
information available. Enter your PIN or present your Tag to view.
3.8 Part Setting
Sometimes your security needs will be a little more complex and
you will need to use the
A B C D
keys.
A typical scenario may be as follows:
A= All Set
B= Bedtime Set
C= Cat in Lounge
To part set, enter your code and select the area A, B, C or D.
NOTE: This feature must be enabled by your installation company.
Alarm Silenced
Low Volts
EURO mini
Area B

EURO
mini
User Guide
Page: 8
For greater flexibility in setting parts of your
system, you can make a choice at the keypad.
Key in your PIN code or present your
Tag.
If you do not wish to set the default area
assigned to your code, simply select the
areas you wish to Set by pressing the
relevant A B C D key(s).
To change your mind, press the relevant
A B C D key(s) again.
Press the ‘Yes’ key to accept
Setting areas will now be displayed, with
the corresponding area keys being lit.
EURO
mini
will now Set the selected area
3.9 Simple Setting
It is also possible to set the EURO mini without using your PIN code or
Tag.
When your system is unset, press the ‘YES’ key, and then select
the area you wish to set. For example, to set area C, press the C
key.
The exit procedure will start.
“beep – beep – beep – “
EURO
mini
is now Set
NOTE: that when using the ‘simple set’ facility, the user who initiated
the set cannot be logged.
3.10 Setting With Faults
There may be a detector on your system that if open when you try to
set will be considered by EURO mini as a ‘fault’. In a domestic setting
you may wish to ignore a window you have deliberately left open in the
summer time. There may be another fault on the system which you
want to ignore when you set the system.
Enter your PIN code or present your
Tag.
The display will ask if you wish to set
with the fault.
To omit the fault, Press ‘YES’ (or ‘NO’ if you don’t!)
The system will then set as normal.
The fault will be omitted for this one setting period only.
SETTING
Area A
SET AREAS
[A ]
Set with Fault?
Bedroom Window

EURO
mini
User Guide
Page: 9
4. Useful Features
4.1 The Chime Facility
The ‘C’ key can be used to select the ‘chime’
facility while the system is Unset.
For example, you may wish to be alerted if
someone enters through a particular door
during the day.
Simply press the ‘C’ key.
The display will show a ‘C’
Now if the door opens you will be alerted by
the ‘chime’ tone.
To cancel the ‘Chime’ function, simply press
‘C’ again.
Note: This is only operative on detectors
programmed for this purpose. If multiple
detectors are programmed to permit this, the
sounder will not distinguish between them.
4.2 Omitting An Input
At some time you may wish to isolate a
detector if a room is occupied.
Enter your PIN code or present your Tag.
While the exit tone is sounding press the
‘YES’ key.
When the ‘OMIT INPUT’ menu is displayed:
Key in the number of the zone you wish to
omit and press ‘YES’.
(Always use a leading zero, eg 02 is input 2)
If it has been accepted it will be displayed on
the screen.
Repeat for any other inputs that need to be omitted.
After 10 seconds
EURO
mini
will begin to set
These inputs will be omitted for this one set period only.
EURO mini
Time: 15:31 c
EURO mini
Time:
15:32
OMIT INPUT?

EURO
mini
User Guide
Page: 10
4.3 Keypad Hold-Up
If you ever need to summon personal
assistance in an emergency, EURO mini allows
you to do so.
Simply press the ‘1’ and ‘7’ keys at the
same time.
To reset:
Enter your PIN code
NOTE:
This facility is only available if your
alarm installer has enabled it. If a dialler is
connected to the EURO mini, the 2-Key Hold Up is not permitted to
send a signal to the Alarm Receiving Centre for police response under
police regulations in England, Wales or Northern Ireland.
EURO mini
Time:15:40
Table des matières
Autres manuels Pyronix Clavier

Pyronix
Pyronix PCX-LCD/UK Manuel utilisateur

Pyronix
Pyronix MATRIX Manuel utilisateur

Pyronix
Pyronix ATLAS 8 PLUS Manuel utilisateur

Pyronix
Pyronix STERLING 10 Manuel utilisateur

Pyronix
Pyronix PCX 162i Mode d'emploi

Pyronix
Pyronix ATLAS 8 Manuel utilisateur

Pyronix
Pyronix ATLAS 4 Manuel utilisateur

Pyronix
Pyronix HIKVISION LEDP/R-WE Manuel utilisateur

Pyronix
Pyronix STERLING 10 Manuel utilisateur

Pyronix
Pyronix EURO mini EUR-068 Manuel utilisateur