1. Symbol in label, manual and product 1
2. Safety Precautions 2
2.1 Before Connecting 3
2.2 In Using 4
3. Introduction 4
3.1 Features 5
3.2 Specification 6
3.3 Panel 8
3.4 Equipment interface instruction 8
4. Safe handling guide 11
4.1 Schematic diagram of solution 11
4.2 Danger label 12
4.3 Tools 13
4.4 Safety gear 13
5. Installation and operation 14
5.1 General guidance 14
5.2 Package items 15
5.3 Installation location 19
5.4 Installation method of multiple batteries 20
5.6 Power on 24
5.7 Power off 26
6. Trouble shooting 26
8. Emergency Situations 30
9. Remarks 31

1
1. Symbol in label, manual and product
Do not reverse connection the positive and negative.
Do not place near open flame
Do not place at the children and pet touchable area.
Caution! Warning! Reminding.
Safety related information.
Risk of battery system failure or life cycle reduces.
Keep away from strong magnetic field.
Warning Fire.
Do not place near flammable material
Read the product and operation manual before operating the
battery system!
Certification Mark for the U.S Market
Certification Mark for the EU Market
Recycle label.

2
Label for Waste Electrical and Electronic Equipment (WEEE)
Directive (2006/66/EC) and its amendments
The certificate label for Bluetooth SIG
The Bluetooth Certification Mark for Janpanese market.
The TUV Mark certificate label for Safety Testing (EN62619)
by TÜV Rheinland
The cTUVus Mark certificate label for Safety Testing
(UL1973) and Functional Safety (IEC60730-1/UL60730-1)
by TÜV Rheinland
2. Safety Precautions
Reminding
1) It is important and necessary to read the user manual carefully (in the
accessories) before installing or using battery. Failure to do so or to follow
any of the instructions or warnings in this document can result in
electrical shock, serious injury, or death, or can damage battery,
potentially rendering it inoperable
2) If the battery is stored for long time, it is required to charge them every six
months, and the SOC should be no less than 90%
3) Battery needs to be recharged within 12 hours, after fully discharged
4) Do not install the product in outdoor environment, or an environment out
of the operation temperature or humidity range listed in manual.
5) Do not expose cable outside

3
6) Do not connect power terminal reversely.
7) All the battery terminals must be disconnected for maintenance
8) Please contact the supplier within 24 hours if there is something
abnormal.
9) Do not use cleaning solvents to clean battery
10) Do not expose battery to flammable or harsh chemicals or vapors
11) Do not paint any part of battery, include any internal or external
components
12) Do not connect battery with PV solar wiring directly
13) The warranty claims are excluded for direct or indirect damage due to
items above.
14) Any foreign object is prohibited to insert into any part of battery
Warning
2.1 Before Connecting
1) After unpacking, please check product and packing list first, if product is
damaged or lack of parts, please contact with the local retailer
2) Before installation, be sure to cut off the grid power and make sure the
battery is in the turned-off mode
3) Wiring must be correct, do not mistake the positive and negative cables,
and ensure no short circuit with the external device
4) It is prohibited to connect the battery and AC power directly
5) The battery supports up to 4 groups of batteries in series. The maximum
charge/discharge voltage should not exceed 57V to avoid the backward
voltage generated by the BMS when the input/output is cut off exceeds the
withstand voltage value of BMS.
6) Please ensure the electrical parameters of battery system are compatible
to related equipment.
7) Keep the battery away from water and fire.

4
2.2 In Using
1) If the battery system needs to be moved or repaired, the power must be
cut off and the battery is completely shut down.
2) It is prohibited to connect the battery with different type of battery.
3) It is prohibited to connect batteries with faulty or incompatible inverter
4) It is prohibited to disassemble the battery (QC tab removed or damaged);
5) In case of fire, only dry powder fire extinguisher can be used, liquid fire
extinguishers are prohibited
6) Please do not open, repair or disassemble the battery except staffs from
Pylontech or authorized by Pylontech. We do not undertake any
consequences or related responsibility which because of violation of safety
operation or violating of design, production and equipment safety standards.
3. Introduction
RT12100G31 is a lithium iron phosphate battery module used to replace
the typical lead-acid battery. The battery can be charged by solar power,
diesel generator, and utility power via relevant AC/DC converter. The
battery can be used for energy storage and providing back-up power for
typical electrical appliances. Due to the long life and high energy density
of lithium batteries, there is a broad market prospect to replace lead-acid
batteries.

5
3.1 Features
1) Products with strong environmental adaptability, structural reliability and
electrical reliability, able to adapt to the harsh automotive environment.
2) Robust power performance. Available for 1C-rate continuous operation
and upto 2C-rate instantaneous discharge.
3) Support both serial and parallel connections. Up to 16 batteries (max. 4
groups in serial) can be connected together per single system.
4) The battery module with low self-discharge loss can be stored for more
than 6 months during normal condition and more than 2 months during
empty condition.
5) Built-in battery management system, supporting intelligent monitoring
via CANBUS/Bluetooth.
6) Cathode material is made from LiFePO4 with safety performance and long
cycle life
7) Battery management system (BMS)has protection functions including
over-discharge, over-charge, over-current, short circuit and high/low
temperature.
8) The system can automatically manage charge and discharge state and
balance voltage between each cell.
9) The size is compatible with the US BCI G31 standard and can completely
replace lead-acid batteries of the same size.
10) Build-in heating film which will automatically heat up the module during
minus temperature for critical environment operation.
11) Build-in Bluetooth unit for remote monitoring and control purpose.

6
3.2 Specification
RT12100G31 Battery Dimension

7
Basic Parameters
Value
Nominal Voltage (V)
12.8
Nominal Capacity (Ah)
100
Dimension (mm)
325(L)*173.5(W)*226(H)
Weight (Kg)
12±0.2
Discharge Voltage Range (Vdc)
10.8~14.4
Recommended Charge Voltage (Vdc)
14 ~ 14.4
Recommend Charge/Discharge Current (A)
50
Max. Continue Charge/Discharge Current (A)
100
Peak Discharge Current (A)
200@30sec
Communication
CAN
500Kbps,
RS485
default for console, 115200bps
Bluetooth
BLE5.0
Dry Contact
2 inputs,2 outputs
Maximum series-parallel configuration
4S4P
Maximum number of battery modules
supported(pcs)
16
Working Temperature
-40℃~60℃*
Environment Temperature
IP rating
IP67
Short circuit rating
500A
Humidity
5 ~ 95%(RH) No Condensation
Altitude(m)
<4000
Certification
IEC/ CE /FCC/ROHS/Telec
/UN38.3
Design life
10+yrs
Cycle Life
>4,500 25℃
Reference to standards
UL1973,IEC62619,FCC,CE ,
Bluetooth SIG, Telec,
* Charging is only available between 0 - 60℃
Between -40 - 60℃, discharge only available for heating film using.

8
3.3 Panel
RT12100G31 Panel Description
3.4 Equipment interface instruction
Power Button
Power button pressed: ready to turn on.
Power button pops back: power off. For storage or shipping.
LED Status Indicators:
Power on/Normal
Flash 1, OFF 1.5S, on 0.5s
Waiting for Addressing or
Communication time out
Flash 2,OFF 1s, on 1s,
System Protect
Flash 3,OFF 0.5s on 1.5s,
Sleep/Power off/System error
OFF
Table des matières