Puretec ESR2 Series Manuel utilisateur

For correct operation & installation it is essential to observe these instructions.
User Guide
Undersink Drinking Water System with Tripla Mixer Tap
ESR2 - Series With Tripla

2
Installation & Operation Manual Copyright © Puretec Pty Ltd 2015
What's inside
Operation...................................................................................................................................... 3
Replacement Guide...........................................................................................................................4
Servicing........................................................................................................................................ 5
Technical Information............................................................................................................ 5
Recommended Working Pressures................................................................................. 5
PART 1 Mixer Tap Assembly
Mixer Tap Installation Guide.............................................................................................. 6
Assembly ...................................................................................................................................... 7
Water Connection Patterns......................................................................................................8
Battery Installation.......................................................................................................................9
Replacement of Ceramic Disc Cartridge(s)................................................................ 9
PART 2 Filter Cartridge Installation
Installation Requirements ......................................................................................................... 10
Installation Procedure.................................................................................................................. 11
Filter Parts Description.................................................................................................................12
Quick Connect Fittings..................................................................................................................12
Cartridge Installation/Changeout .......................................................................................... 13
UV Installation..................................................................................................................................14
Tripla T1 Parts Description............................................................................................... 16
Tripla T2 Parts Description............................................................................................... 17
Tripla T3 Parts Description............................................................................................... 18
Tripla T4 Parts Description............................................................................................... 19
Tripla T5 Parts Description............................................................................................... 20
Tripla T6 Parts Description............................................................................................... 21
Warranty ..................................................................................................................................22-23

3
Copyright © Puretec Pty Ltd 2015 Puretec Tripla™ | Triple Action Tapware
Puretec Customer Service
Thank you for purchasing Puretec ESR2-Tripla water lter system. Your system is a
proven performer manufactured from only quality materials and components and will
give years of ‘spring fresh’ water free of impurities if maintained properly.
The Puretec ESR2 system cartridges need replacing regularly to maintain optimum per-
formance. This is a simple procedure when following instructions. For cartridge replace-
ments contact your nearest Puretec stockist.
The system is designed for metropolitan supply water but can be used in other situa-
tions. For other types of water supply please contact your local Puretec stockist or call
our Puretec Customer Service Helpline prior to installing the tap.
Customer Service Helpline 1300 140 140 (Australia) 0800 130 140 (New Zealand)
Caution: Do not use with water that is microbiologically unsafe or with water of unknown
quality without adequate disinfection before or aer the system. This product must be
installed in accordance with local plumbing regulations by a licensed plumber.
Operation
The Puretec ESR2-Tripla system is designed to run economically for many years and this
is dependant on the initial installation and periodical maintenance.
Flush systems for 10 minutes aer any period of non-use more than 2 days. For a pe-
riod of non-use of 2 weeks or more, it may be necessary to replace cartridge.
Chrome Plated Surface - should only be cleaned with liquid detergent or soap and water.
Under no circumstance should any abrasive or acid base cleaning agents be used.

4
Installation & Operation Manual Copyright © Puretec Pty Ltd 2015
Replacement Guide
To maintain the high quality of the puried water the cartridges need changing every 6
months (this is dependant on water quality and usage).
You can obtain replacement cartridges and/or lamp from your local Puretec dealer and
to maintain performance and warranty use genuine Puretec replacements.
A B C
ESR2 PL051 MC011-S RL2
Replace cartridges every 6 months. Replace all RL coded
products every 12 months.
Other cartridges are available to suit a range of requirements upon request.
Important note: When replacing cartridge, ensure you reset the LED reminder light by re-
moving/replacing the battery from the rubber seat. Please refer to page 7 for a detailed
diagram.

5
Copyright © Puretec Pty Ltd 2015 Puretec Tripla™ | Triple Action Tapware
Servicing
Periodically clean the aerator for any lodged sediment that may restrict ow. A Puretec
water lter is highly recommended for product longevity.
Should it be necessary to have your mixer serviced while under warranty, please carry
out the following procedure:
1. Firstly call the plumber, preferably the one that has installed it, (most problems
are caused by the supply lines not being cleaned out properly, prior to connecting
the mixers).
2. Make sure that the plumber has installed your mixer according to the Instruction
Guide.
3. If the plumber is satised that he cannot rectify the problem then contact your
plumbing supply store or your local Puretec stockist.
Important: We do not recommend the dismantling of any internal part of the mixer
purely to see what is inside as this will breach your warranty.
Technical Information
Puretec mixers can be used in conjunction with:
• Pressure storage hot water system
• Any mains water pressure not exceeding 500 kPa
• Maximum hot water temperature of 60°C
• Instantaneous hot water system
Recommended Working Pressures
• Minimum working pressure 50 kPa (7.5 PSI)
• Maximum working pressure 500 kPa
It should be noted that water mains pressure builds up during o peak periods, mainly
at night, sometimes doubling or trebling normal daytime pressures.
Note: Not suitable for unequal pressure. On high pressure areas where the pressure
exceeds the recommended working pressure as indicated above pressure limiting valves
must be installed or warranty is voided.

6
Installation & Operation Manual Copyright © Puretec Pty Ltd 2015
HOT
Mixer Tap
Rubber Washer
Sink Faucet
Hole (Ø33mm)
Water Fiter
COLD
Metal Washer
Rubber Washer
Locking Nut
Retainer Screw
Metal Pipe
Mixer Tap Installation Guide
Note: It is important to ush out the supply pipes to the mixer
before connecting the exible hoses, with the initial installation, so
no foreign matter can enter into the cartridges.
A Puretec Water Filter is highly recommended for product longevity.

7
Copyright © Puretec Pty Ltd 2015 Puretec Tripla™ | Triple Action Tapware
Step 4. Place the retainer screw
through the hole in each spacer and
screw to the hole on the bottom of
the faucet.
Then, use a wrench to lock the
retainer nut.
Rubber Spacer
Locking
Nut
Retainer Screw
Zinc Spacer
Assembly
O-Ring
Brass Base
1
2
Step 1. Connect the hoses to the
faucet and tighten them.
Only use hand to screw the exible
hose. Do not over tight. Don't use any
tools.
Step 2. Put brass base with o-ring to
the bottom of the faucet.
Basin or Sink
33mm dia.
Hole
Step 3. Put the hoses through the
basin or sink. Required through hole
size is Ø33mm.

8
Installation & Operation Manual Copyright © Puretec Pty Ltd 2015
Retainer
Screw
HOT Water
Connection
COLD Water
Connection
Water Filter
Connection
For TRIPLA T1 & T2
Water Connection Patterns
Retainer
Screw
HOT Water
Connection
COLD Water
Connection
Water Filter
Connection
For TRIPLA T3 to T6
Retainer
Screw

9
Copyright © Puretec Pty Ltd 2015 Puretec Tripla™ | Triple Action Tapware
Battery Installation - LED reminder light
1. Remove the black battery seat from the
faucet canopy
2. Install battery into the battery seat,
positive side up.
Note: red light ashes
twice and then followed
by the blue light
3. Reinstall battery seat assembly into the
faucet canopy
Important note: Battery must be replaced when changing cartridges.
5. Red light ashes indicates your cartridges
are due to be changed (usage has
exceeded 3,000 minutes or 12 months).
Please change the battery when
changing the lter cartridge(s).
Positive
side up
Negative on
the PCB
4. Blue light ashes during
normal operation.
Replacement of Ceramic Disc Cartridge(s)
1. Hot/Cold Outlet
• Remove hot and cold water indicator then release screw in lever and li lever o,
now you can unscrew dome cap and loosen the cartridge lock nut.
• Li out old cartridge and clean inside making sure no old O-rings are still stuck
inside cartridge housing.
• Insert new cartridge making sure O-rings on bottom of new cartridge have not
fallen o and lugs in bottom of cartridge line up with holes in cartridge housing.
• Now you can tighten lock nut with a torque wrench to 14 newton meters, then
reinstall dome cap, lever screw and hot and cold water indicator.
2. Filtered/Rain Ancillary Outlet
• Remove front button cover using ne-edged 1.2mm screwdriver.
• Unscrew handle then remove cartridge by unscrewing it anti-clockwise, using 5/8”
socket. Install cartridge by completing removal instructions as above, in reverse
order.
• Ensure cartridge is rmly tightened not over tightened.

10
Installation & Operation Manual Copyright © Puretec Pty Ltd 2015
Filter Cartridge Installation
This system comes complete with an installation kit enabling it to be connected to
15mm (½”) copper pipe (Cold supply only - hot water should be ltered prior to heating).
This product must be installed in accordance with local plumbing regulations by a
licensed plumber.
Installation Requirements
• 15mm (½”) Cold water line.
• Power supply: 240 VAC.
• Supply pressure: 300-875 kPa. Install pressure limiting valve if pressure exceeds
875 kPa.
• Supply temperature 3°C - 52°C.
• Suitable spot for faucet.
• Alternative ttings may be required if being connected to anything other than
15mm (½’) copper pipe.
• Caution: Do not use with water that is microbiologically unsafe or of unknown
quality without adequate treatment before or aer the system.
Application warning; minimum water characteristics must be met before
installation of Radre™ to ensure proper operation and continuous protection.
Iron less than 0.3 mg/L
Hydrogen Sulphide less than 0.05 mg/L
Suspended Solids less than 10 mg/L
Manganese less than 0.05 mg/L
Hardness less than 110 mg/L
Hy
Autres manuels pour ESR2 Series
1
Table des matières
Autres manuels Puretec Système d'eau
Manuels Système d'eau populaires d'autres marques

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuel utilisateur

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuel utilisateur

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuel utilisateur

Microline
Microline T.F.C.-4 Manuel

Eureka Forbes
Eureka Forbes Aquaguard Select Manuel utilisateur

Cetetherm
Cetetherm AquaEfficiency Manuel utilisateur