500TRM-002 Page 7 of 22 March 2007
Section 4 Specifications and performance
The most current information on the performance capability of these sensors is accessible on the Proteus
website at www.proteusind.com.
Flow Range
GPM 0.15 - 2.0 0.3 – 4.5
LPM 0.6 – 7.5 1.2 – 17.0
Connections Part Number
9/16 -18 SAE 0504SA2 0504SA4
¼” FNPT 0504SN2 0504SN4
Liquid operating Limits
Temperature -40 to 140oC -40 to 284oF
Electronics must be thermally isolated from flow sensor at temperatures
above 85°C and below dew point.
Pressure 1720 kPa 250 psi
Kinematic Viscosity To 120 centistokes
Wetted Materials
Flow Sensor Body 304 Stainless Steel
Faceplate 316 Stainless Steel
Sealing O-ring Viton ® . Other materials are available.
Rotor Carbon fiber-filled Nylon. Other materials are available.
Rotor Shaft 316 Stainless Steel. Other materials are available.
Meter Performance
Voltage Output 0 - 5 VDC for the 2.0 GPM or 4.5 GPM.
Accuracy ± 2 % of range.
Improved accuracy and linearity performance over smaller flow ranges can
be achieved by specialized NIST-traceable calibration procedures.
Linearity Better than ± 1% from 10 to 100% of nominal flow range
Repeatability Better than ± 0.5% above 10% of nominal flow range
Switch Performance
Trip Point Selection 16 position changes trip points in steps of 6% of nominal flow range with fine
adjustment between steps.
Hysteresis / Dead Band < 5% of actual flow rate
Switch type Relay Closure
Relay rating SPDT 48 VDC, 1.0 A
Electrical
Power Requirements 24 VDC, 40 mA
Electrical Connection Plug type EDZ1550/8 with screw fastening of 8 conductors up to #16 gauge.
Remote Electronics Optional mounting locates electronics up to 30 ft from flow sensor. Required
for operation above 85°C.
Flow Certification Standard products are provided with certificates of compliance. Specialized
calibration certificates are optionally available.
Digital Display Optional panel mounted displays flow rate GPM or LPM on 3½ digits.