GC1380 User Manual 70-0018A-B
Prosilica Inc.
2
Specifications
Sensor Type Sony ICX285AL CCD (ICX285AQ for color)
Sensor Shutter Type Progressive Interline
Image Resolution 1360 x 1024 pixels
Pixel Size 6.45µm x 6.45µm
Optical Format 2/3 inch
Lens Mount C-mount with adjustable back focus
Color Sensor Filter Pattern
†
Bayer
Full Resolution Frame Rate 20.2 fps
Frame Rate (640 x 480 ROI) 37 fps
I/O 1 isolated input/output, 1 non-isolated input/output,
1 RS-232 input/output
Power Requirements Less than 3.3W
††
Digitization 12 Bits
Trigger latency* 3.7us for non-isolated I/O, 5us for isolated I/O
Trigger Jitter* ±20ns for non-isolated I/O, ±0.5us for isolated I/O
Tpd* 10ns for non-isolated I/O, 1.3us for isolated I/O
Operating Temperature 0 to 50 Celsius***
Operating Humidity 20 to 80% non-condensing
Size 33mm (height) x 46mm (width) x 59mm (length)
Weight 104g
Hardware Interface Standard IEEE 802.3 1000BASE-T, 100BASE-TX
Software Interface Standard GigE Vision Standard 1.0
Regulatory Conforms to CE, FCC
† Applies to GC1380C only.
†† Power consumption will increase with reduced ROI imaging and color interpolation.
††† Nominal operating voltage is 12V. Cameras have been tested at 12V.
* See Notes on Triggering in the Addendum.
***DUE TO THE SMALL PACKAGING AND HIGH SPEED OF THE GC CAMERAS, SPECIAL
CARE IS REQUIRED TO MAINTAIN A REASONABLE OPERATING TEMPERATURE. IF THE
CAMERA IS TO BE OPERATED IN A WARM ENVIRONMENT, IT IS SUGGESTED THAT THE
CAMERA BE MOUNTED ON A HEAT SINK SUCH AS A METAL BRACKET AND THAT
THERE IS SUFFICIENT AIR FLOW.