PROPOINT 9033895 Manuel utilisateur

V1.0 9033895
Please read and understand all instructions before use. Retain this
manual for future reference.

9033895 Single-Phase Electric Air Compressor V1.0
2 For technical questions call 1-800-665-8685
Air tank size
120 gal.
Tank type
Horizontal stationary
Motor type
Electric
Horse Power
10
Voltage rating
208/230V AC
Frequency rating
60 Hz
Phase
Single
Air delivery @ 40 PSI
38 CFM
Air delivery @ 90 PSI
36 CFM
Air delivery @ 175 PSI
32 CFM
Max. pressure rating
175 PSI
Factory on/off setting
125/150 PSI
Duty cycle
50%
Drive type
Belt
Number of stages
2
Number of cylinders
4
Cylinder material
Cast iron
Lubrication type
Splash
Outlet connection size
1 in.
Outlet connection type
Ball valve
Drain type
Manual
Finish
Powder coated
Overall dimensions
50L x 27W x 73H in.
Certification
CSA-US #248159
Please familiarize yourself with the hazard
notices found in this manual. A notice is an alert
that there is a possibility of property damage,
injury or death if certain instructions are not
followed.

V1.0 Single-Phase Electric Air Compressor 9033895
Visit www.princessauto.com for more information 3
DANGER! This notice indicates an immediate and
specific hazard that will result in
severe personal injury or death if the
proper precautions are not taken.
WARNING! This notice indicates a specific hazard
or unsafe practice that could result in
severe personal injury or death if the
proper precautions are not taken.
CAUTION! This notice indicates a potentially
hazardous situation that may result in
minor or moderate injury if proper
practices are not taken.
NOTICE! This notice indicates that a specific
hazard or unsafe practice will result in
equipment or property damage, but not
personal injury.
This stationary, horizontal style air compressor
features a large 120 gallon capacity. It delivers
32 CFM of airflow at a maximum 175 PSI, making it
ideal for continuous, indoor use with multiple
outputs. It features a 208/230V, single-phase
electric motor, splash lubrication, an industrial-
duty 2-stage pump, and sturdy cast-iron
construction with a powder-coated finish.
WARNING! Read and understand all instructions
before using this tool. The operator must follow
basic precautions to reduce the risk of personal
injury and/or damage to the equipment.
Keep this manual for safety warnings, precautions,
operating or inspection and maintenance
instructions.

9033895 Single-Phase Electric Air Compressor V1.0
4 For technical questions call 1-800-665-8685
1. Operate in a safe work environment. Keep your
work area clean, well-lit and free of
distractions. Place lights so you are not
working in a shadow.
2. Keep anyone not wearing the appropriate safety
equipment away from the work area.
3. Store tools properly in a safe and dry
location. Keep tools out of the reach of
children.
4. Do not install or use in the presence of
flammable gases, dust or liquids.
WARNING! Wear personal protective equipment
approved by the Canadian Standards Association
(CSA) or American National Standards Institute
(ANSI).
1. Always wear impact safety goggles that provide
front and side protection for the eyes. Eye
protection equipment should comply with CSA
Z94.3-07 or ANSI Z87.1 standards based on the
type of work performed.
3. Wear gloves that provide protection based on
the work materials or to reduce the effects of
tool vibration.
4. Wear protective clothing designed for the work
environment and tool.
5. Non-skid footwear is recommended to maintain
footing and balance in the work environment.
6. Wear a NIOSH approved respirator when working
on materials that produce hazardous fumes, dust
or particulate matter.

V1.0 Single-Phase Electric Air Compressor 9033895
Visit www.princessauto.com for more information 5
7. This tool can cause hearing damage. Wear
hearing protection gear with an appropriate
Noise Reduction Rating to withstand the decibel
levels.
Control the tool, personal movement and the work
environment to avoid personal injury or damage to
the tool.
1. Do not operate any tool when tired or under the
influence of drugs, alcohol or medications.
2. Avoid wearing clothes or jewelry that can
become entangled with the moving parts of a
tool. Keep long hair covered or bound.
3. Do not overreach when operating the tool.
Proper footing and balance enables better
control in unexpected situations.
WARNING! DO NOT let comfort or familiarity with
product (gained from repeated use) replace strict
adherence to the tool safety rules. If you use this
tool unsafely or incorrectly, you can suffer serious
personal injury.
CAUTION! The air compressor motor and/or engine
will get hot while in operation. Never touch the
discharge tubing, motor, or compressor pump while
in operation. The compressor operates
automatically while the power is connected and the
switch is set to AUTO.
1. Use the correct tool for the job. This tool was
designed for a specific function. Do not modify
or alter this tool or use it for an unintended
purpose.
2. Do not use the tool if any parts are damaged,
broken or misplaced. Repair or replace the
parts. Only use approved replacement parts with
matching specification.

9033895 Single-Phase Electric Air Compressor V1.0
6 For technical questions call 1-800-665-8685
3. Serious injury or death may occur from an air
tank explosion if the air tank is not properly
maintained or if modifications, alterations or
repairs are attempted. Drain air tank daily or
after each use. Never drill into, weld, patch
or modify the air tank. Replace the tank
immediately or replace the entire compressor,
if a leak develops.
4. Serious injury or death may occur if
modifications are made to the pressure switch,
safety relief valve or other components that
control the tank pressure. Never make
adjustments to the components that control tank
pressure. Do not make alterations to the
factory operating pressure settings. Check
operation of the pressure relief valve on a
regular basis and never operate without a
factory approved pressure relief valve.
5. Check the manufacturer’s maximum pressure
rating for air tools and accessories.
Compressor outlet pressure must be regulated so
as to never exceed the maximum pressure rating
of the tool.
6. Serious injury may occur if a fire is caused by
overheating due to inadequate ventilation or
restrictions to any of the compressor’s
ventilation openings.
7. Serious burn injuries could occur from touching
exposed metal parts such as the compressor head
or motor during operation and even after the
compressor is shut down for some time. Never
touch any of the exposed metal parts during
operation and for an extended period of time
after the air compressor has shut down. Do not
attempt maintenance on the unit until it has
been allowed to completely cool.

V1.0 Single-Phase Electric Air Compressor 9033895
Visit www.princessauto.com for more information 7
8. Serious injury may occur if repairs are
attempted with damaged, missing or removed
protective guards, shrouds or missing covers.
All repairs to the air compressor should be
made only by authorized or trained service
personnel.
9. This unit starts automatically. Always shut off
the compressor and bleed all pressure from the
system before servicing the compressor and when
the compressor is not in use.
10. Failure to transport or operate the air
compressor properly may result in major repair
expenses. Always run the compressor in a level,
secure position that keeps it from tipping or
falling during use.
11. Do not operate without an air filter or in a
corrosive environment.
12. Always transport in a level position and use
protective mats to keep truck beds clean, etc.
Fasten the compressor down securely. Pressure
must be released from the tank before
transporting.
13. In cold climates, drain the tank after each use
to avoid ice buildup.
14. The valve for this compressor is factory
installed to prevent over pressurizing. Do not
tamper with or adjust the safety valve.
WARNING! To reduce risk of electric shock, be
certain that the plug is connected to a properly
grounded receptacle.
1. Disconnect the tool from the power supply
before making any adjustments, changing
accessories, cleaning, servicing or when
storing. Such preventive safety measures reduce
the risk of starting the tool accidentally.

9033895 Single-Phase Electric Air Compressor V1.0
8 For technical questions call 1-800-665-8685
2. Do not expose the tool to rain, snow, frost or
any other damp or wet conditions. Water
entering a tool will increase the risk of
electric shock.
3. In the event of a power failure, unplug the
machine as soon as the power is interrupted.
The possibility of accidental injury could
occur if the power returns.
4. Make certain the power source conforms to
requirements of your equipment (see
Specifications).
5. This compressor must be connected to a
grounded, metallic and permanent wiring system
or an equipment-grounding terminal or lead.
WARNING! All wiring should be performed by a
qualified electrician.
1. Inspect the tool's air hose for cracks, fraying
or other faults before each use. Discontinue
use if the air hose is damaged or hissing is
heard from the air hose or couplers. Replace
the defective air hose.
2. Do not allow people, mobile equipment or
vehicles to pass over the unprotected air hose.
Position the air hose away from high traffic
areas, in a reinforced conduit or place planks
on both sides of the air hose to create a
protective trench.
3. Prevent damage to the air hose by observing the
following:
3.1 Never carry the tool by the air hose.
3.2 Keep the air hose behind the tool and out
of the tool's work path.
3.3 Keep the air hose away from heat, oil,
sharp edges or moving parts.

V1.0 Single-Phase Electric Air Compressor 9033895
Visit www.princessauto.com for more information 9
3.4 Do not wrap the air hose around the tool as
sharp edges may pierce or crack the air
hose. Gently coil the hose and either hang
on a hook or fasten with a device to keep
hose together when storing.
4. A damaged or disconnected air hose under
pressure may whip around and inflict personal
injury or damage the work area. Secure the
compressor's air hose to a fixed or permanent
structure with clamps or cable ties.
5. Install an in-line shutoff valve or regulator to
allow immediate control over the air supply in
an emergency, even if a hose is ruptured.
6. Check the manufacturer’s maximum pressure
rating for air tools and accessories.
Compressor outlet pressure must be regulated to
never exceed the maximum pressure rating of the
tool (see Specifications). Exceeding the
maximum PSI rating can create a bursting
hazard, causing injury and property damage.
7. Serious injury may occur from loose debris being
propelled at high speeds from the compressed air
stream. Always wear OSHA approved safety glasses
to protect the eyes during operation of the air
compressor.
8. Always turn off the air compressor and drain
tank pressure completely before attempting
maintenance or attaching air tools. Release
pressure slowly from the system.
9. Serious injury or death may occur from inhaling
compressed air. The air stream may contain carbon
monoxide, toxic vapors or solid particles. Never
inhale compressed air directly from the pump or
air tool.

9033895 Single-Phase Electric Air Compressor V1.0
10 For technical questions call 1-800-665-8685
WARNING! Do not operate the tool if any part is
missing. Replace the missing part before
operating. Failure to do so could result in a
malfunction and personal injury.
Remove the parts and accessories from the packaging
and inspect for damage.
Make sure that all items in the Identification Key
are included.
A Air storage
tank
B Pump
C Electric motor
D Pressure switch
E Valve
F Feet
G Magnetic starter
Letter references in parenthesis (A) refer to the
included Identification Key.
1. Position the compressor in a work space or area
that adheres to the following criteria:
•Indoors
•Level, sturdy surface
•12 in. away from any wall or obstruction
•Clean and well-ventilated
2. Never place objects against or on top of an air
compressor.
Table des matières
Langues :
Autres manuels PROPOINT Compresseur d'air
Manuels Compresseur d'air populaires d'autres marques

Campbell Hausfeld
Campbell Hausfeld RP3300 Guide de démarrage rapide

Ingersoll-Rand
Ingersoll-Rand UP6 20 HP Manuel utilisateur

Hitachi
Hitachi EC99S Manuel de l'opérateur

Parkside
Parkside PKO 270 A1 Manuel utilisateur

Sullair
Sullair 185 Manuel utilisateur

Clas Ohlson