polimek SmartGuard E-6006 Manuel utilisateur

Walk Through Metal Detector
E-6006/SE-1806/SE-3306
User Manual
!
!!!!!!!!!!!!!!!!!!!!!!!!!!
!
Polimek(Electronics(and(Computer(Industry(Inc.(
Atatürk'Organized'Industrial'Zone'10024'St.'No:'9'Cigli-Izmir'/TURKEY'
Tel:'+90'[232]'328'1645'(pbx)'–'Fax:'+90'[232]'328'1674'Whatsapp:'+90'[532]'498'3402'
www.smartguard.com.tr'–'www.polimek.com.tr'Email:'ekin[email protected]om.tr'

Contents
【NOTES】 ............................................................................................... 1
【PRODUCT SPECIFICATION】 ........................................................... 2
【INSTALLATION ENVIRONMENT】 ................................................. 3
【PERFORMANCE AND FEATURES】 ................................................ 4
【PARTS】 ................................................................................................ 5
【INSTALLATION】 ............................................................................... 6
【CONTROL PANEL】 ........................................................................... 7
【DETECTION ZONES】 ........................................................................ 7
【OPERATION】 ..................................................................................... 8
【PASSWORD MANAGEMENT】.........................................................13
【OPTIONAL FUNCTIONS】................................................................13
【DETECTION ADJUSTMENT】 ........................................................ 14
【FAQ】 .................................................................................................. 15
【TECHNICAL PARAMETERS】 ........................................................ 16
【FACTORY PARAMETERS】 ............................................................ 17
【PACKING LISTING】 ........................................................................ 17
【WARRANTY CARD】 ....................................................................... 18

1
【
NOTES
】
PLEASE READ THE FOLLOWING INSTRUCTION CAREFULLY BEFORE
OPERATION
:
1. It's available for indoor use, if need to use outdoor, please use canopy to protect it
against rain.
2. Choose the smooth and stable installation place, to avoid false alarm caused by the
waggling.
3. Make sure the position of the left and right detector heads in the panels are correct
before installation.
4. It will have a 1 minute self-inspection after power-on, to achieve the excellent
performance.
5. The passers must abide by the predefined standby time and alarm time (>1 s)when
checking, walking through one by one, do not crowded around the detector to
interfere with infrared induction.
6. Don't knock and crash the detector during security checking to avoid false alarm,
even the damage.
7. Do not disassemble the HV control units except the professional technician to
avoid the artificial accident.
8. Detector can be repaired free with the warranty card attached the goods if under
the warranty.

2
【
PRODUCT SPECIFICATION
】
Walk through metal detector is a stationary-mounted detection equipment, or
WTMD for short, mainly used to check the metal objects hidden in human body.
When the passers walk through the WTMD, it will alarm and display the alarm zone
at once, if the metal size in human body is more than the predefined metal parameter
of weight, quantity or shape, so that security staff can find the person with prohibited
metal objects in time.
As one of the the highest technical domestic products to meet the needs of users in
various industries.Our WTMD are in strongest ability of induction and detection,
higher sensitivity, stronger anti-interference,

3
【
INSTALLATION ENVIRONMENT
】
1. Stationary Metallic Items
When installing the WTMD, it should stay away from the stationary or fixed bulk
metal items 2 meters; otherwise it will affect the sensitivity and cause false alarm.
Metal items such as: aluminum alloy / stainless steel doors and windows, with
reinforced wall, etc.
2. Movable Metallic Items
The big metal items can be moved, should stay away from the device about 5 meters
to avoid false alarm. Especially install the detector at factory gate or ground floor,
need to pay attention to the effect of rolling gate, iron security doors, elevators and
cars on the detector.
3. Floor Vibration
The floor should be flat and fixed, to avoid false alarm after installation by the
movement of people walking or moving and shaking of metal objects.
4. Electromagnetic Radiation And Electromagnetic Interference
Because the device uses bilateral transceiver technology, therefore, any
electromagnetic interference sources and electromagnetic radiation source are not
allowed to close the device, the recommended distance is 1~2 meters. The parameters
of the distance are determined by the installation environment, and different
installation environments with different parameters.
The electromagnetic interference sources and electromagnetic radiation sources as
following:
Electrical Control Box, Radio Equipment, Interphone, Electronic Computer And
Peripheral Equipment, Video Monitor, High Power Motor, Power Transformer, Ac
Power Lines, Thyristor Control Circuit (High Power Switching Power Supply,
Inverter Welder), Engine, Motor etc.
5. Side-By-Side Using(more than 2 pieces WTMD)
When installing the WTMD side by side more than 2 pieces, there will be a
certain degree of influence between each WTMD, it is related to the distance and the
frequency between WTMD. The distance between 2 WTMDs can not be less than
50cm. Specific distance parameters according to the actual environment and the
selection of the work frequency to adjust.
6. Can not install the device in windy place. It would cause of false alarm if the
device would slight swing in the wind.

4
【
PERFORMANCE AND FEATURES
】
Accurate Positioning: 6/18/33 overlapping network detection zone, bilateral transmit
and receive, can be accurately positioned to the detected objects, intuitively display of
the target location.
Micro Processor Technology: the scanning electromagnetic wave generated by the
microcomputer control circuit, the scanning rate can be precisely controlled. All the
parameters can be set through the control panel as needed to ensure the sensitivity
with flexibility, reliability, stability.
Sensitivity Adjustable: each detection zone has 100 sensitivity level (0 ~ 99). Preset
metal size, you can exclude the coins, keys, jewelry, belt buckle etc.
Digital Pulse Technology: Digital Signal Processing(DSP) and filtering system, has
excellent anti-interference ability.
Password Protection: only the correct password can change the sensitivity and other
parameters. Password with five digits, can be set by the user.
Count Statistics: pass count and alarm count.
Harmless to Human Body: harmless to heart pacemaker, pregnant women, magnetic
floppy disk, recording tapes etc.
Power Supply Security: the power supply on the top of the control box, waterproof.
Waterproof Foot Cover: not only can fixed the device, but also waterproof.
Waterproof: using PVC synthetic material, special technology, waterproof, fireproof,
shockproof.
Easy to Install: the system is integrated design, just 20 minutes to complete the
installation or disassemble.

5
【
PARTS
】
1, Door Panel 2, Crossbar 3, Integrated Host 4, Alarm zone LED 5, Infrared
Sensors 6, Waterproof Foot Cover 7, Power Line&Signal line Interface

6
【
INSTALLATION
】
1.Remove the Integrated Host and the packaging of the door panels.
2.The main chassis display panel up, left and right side of the door as shown in the
figure, then connect the left and right door to the main box respectively with bolts and
nuts locked tightly。
3.Make sure the door probe line on the left and right were tightly inserted into the
corresponding socket on the motherboard, pay attention to tighten, do not loose.
4.Raise the metal probe door to the vertical position and move to the specified
working position.
5.Make the power line in the door side of connected to the power supply into the
working state.

7
【
CONTROL PANEL
】
1. LED Digital Display: show passer number.
2. The alarm number.
3. Interference Signal Strength Indicator: alarm indicator (red light)
4. “ENTER" Key: confirm the data after setting, and use as plus key when setting
the district sensitivity.
5. “SETUP" Key:
① convert various data, and use as minus key when setting the district sensitivity.
② long press 5s to adjust working frequency, 1~16 bands to choose.
6."SELECT" Key: choose each program, and use as plus key when entering
password .
7. "RESET" Key: zero clearing for number of passer and alarm.
【
DETECTION ZONES
】
A: Control Unit: signal strength indicator, the number of passer and alarm
Standby Indication: indicator in red when alarming.
B: LED bar Alarm
As Figure-1, there are six sets of unique pinpointing LEDs, which represent six
detection zones(from bottom to top 1.2.3.4.5.6).Same way for Figure-2 and Figure-3.
Pinpointing LEDs have 2 states in red bright or not bright. It’s in red alarm when
passers’ body with or exceed stated metal content,if there are multiple targets, then
each target location of the LEDs will be lit with alarm sound at the same time, (Except
for mute).
C: Infrared Sensor(IR)
When the power is turned on, the WTMD starts to work, the infrared sensor can
effectively stop the alarm when nothing pass it to avoid false alarm. The passers could
be exactly counted by IR. Regardless of any cause of the alarm in transit, he has to go
through the WTMD again.

8
Figure-1 Figure-2 Figure-2
【
OPERATION
】
6 Zone Walk Through Metal Detector
1. Long press “SELECT”3 seconds, entering“P-0”or ”P-1”mode. (“P-0” for
Inspection, “P-1” for Test Flying Object or Test Mode.) Adjust to “P-0” mode and
press “ENTER”to confirm entering P-0 mode.
2. Long press“SETUP” entering“Frenquency Adjustment”,will show “F-xx”.
“xx”means Device Frequency Code. Press “SELECT” can adjust the Frequency. Press
“ENTER” confirm the selection. In order to avoid signal interference, the frequency
code of each adjacent device must be different. (For user convenient operation, we
have particularly simplified the Frequencies to 16 total, which can for unlimited
devices installation!)
3. Press “SELECT”, will show “12345”, which is factory original password. If have
changed the original password, please input the new correct password. (For password
input details please refer to “Password Management”)
4. Press “ENTER” again, will show “00000”, means password correct can go to next
Ce manuel convient aux modèles suivants
2
Table des matières
Manuels Détecteur de métaux populaires d'autres marques

Steinberg Systems
Steinberg Systems SBS-MD-22 Manuel utilisateur

Zircon
Zircon MetalliScanner m60c Manuel utilisateur

nalanda
nalanda MD027 Manuel utilisateur

REV Ritter
REV Ritter CB-7005 Manuel utilisateur

Minelab
Minelab F1A4 Manuel utilisateur

Fisher Research Labs
Fisher Research Labs F70 Manuel utilisateur

Steinberg Systems
Steinberg Systems SBS-MD-12 Manuel utilisateur

GOLDEN MASK
GOLDEN MASK 5 Manuel utilisateur

Grizzly
Grizzly YM 203 Manuel utilisateur

Fisher Research Labs
Fisher Research Labs 1280-X Aquanaut Manuel utilisateur

Treasure Cove
Treasure Cove Vibra-Probe 560 Manuel utilisateur

Accurate Locators
Accurate Locators XL16 IMAGER Manuel utilisateur