POER PTR16 Manuel utilisateur

User Manual
Wireless Programmable
Room Thermostat
Model No. : PTC10/PTR16
Power to control your heating
Anytime, Anywhere
smart controls
Scan for App
Add.: 19th. Floor, Xingtu Building, No.451
Wulianwang Street, Binjiang Zone, Hangzhou
City, 310051 Zhejiang Pro., CHN.
www.poersmart.com
Zhejiang Lancable Tech., Co., Ltd
Tel.: +86-571-87117288
Fax: +86-571-28190666
E-mail: [email protected]

01
1. Overview
This wireless programmable room thermostat kit can be used to control high-power
heating equipment on electric heating or infrared heating; but also be applied to low
power AC(Alternating Current) devices like electric actuators.
It contains a wireless programmable room thermostat PTC10 and a wireless receiver
PTR16, the two units are linked by Radio Frequency. (If your kit is Wi-Fi thermostat,
there is a gateway PTG10 accessing your thermostat to internet?)
This thermostat is a programmable room thermostat 5+2 Days / 7 Days/1 day product.
5+2 days allows you to set a program for weekdays and a program for the weekend. 7
days allows you to set a same program for every day of the week. 1 day functionality
allows you to set a different program for every day of the week. Each program type
allows you to set 7 time and temperature events.
Controls and Display Layout
A
B
C
D E G
H I
J
K
EF
Days
Temperature
Auto, Manual Holiday mode,
Time
RF
ECO
Copy Clock set
Child lock
Program set
Forst protection
Heating
Low bettery warning
Open window
Confirm
Return
Humidity
Program setting time
+
adjustment
or - buttons for setting
A
B
C
D
E
F
G
H
I
J
K
Contents
LEARN
LEARN MODE
OVERRIDE
EMPTY BUTTON
LEARN MODE
Ⅰ
Ⅱ
Ⅰ
1. Overview
2. System Installation
2.1 Install and Wiring Receiver
2.1.1 Install Receiver
2.2 Activate Batteries and Install Thermostat
2.2.1 Activate Batteries
2.2.2 Install Thermostat
2.3 System Check
3. Operation Thermostat
3.1 Clock Setting
3.2 Program Setting
3.2.1 Pre-set Program
3.2.2 To adjust the Pre-set Program
3.3 Override Mode
3.4 Manual Mode
3.5 Holiday Mode
3.6 ECO Mode
3.7 OFF Mode(Frost Protection)
3.8 Child Lock
4. User Option
5. User Options Table
6. Product Specification
Wireless Programmable Thermostat
Wireless Receiver
01
02
02
02
04
06
06
06
07
07
2.3.1 RF Signal Pairing
2.3.2 RF communication test 14
16
16
18
18
18
21
22
23
24
25
25
26
27
28
28
29
2.1.2 Receiver’s wiring

02 03
2. System Installation 2. System Installation
2.1 1 Install . Receiver
Follow the installation diagrams to install and connect the receiver PTR16 correctly.
2.1 Install and Wiring Receiver
Note: 1 The installation and wiring should be operated by trained personal.
Note: The Receiver should be mounted in a suitable location that is both accessible for
the connection of mains and control wiring, and allows good reception of the RF signal.
The Receiver needs a 100~240V AC mains supply to operate, and this should be fused
appropriately (16A max.).
2
Note:
with water, moisture or condensation.
3 The Receiver should be mounted in a location where it will not come into contact
Note: 4 Before wiring the terminals, please check the wiring drawings carefully.
A B CABC
NL
2
max 2.5mm
A B C A B CNL
ABC A B C
NL

04 05
2. System Installation 2. System Installation
L N
Burner (direct control)
N L A B C A B C
AC
230V
Imax
IN
16A
50Hz
L1 N1
NTC
N L A B C A B C
AC
230V
Imax
IN
16A
50Hz
L1 N1
NTC
L N
Electric heater
Thermal actuator
R B BL BR
N L A B C A B C
AC
230V
Imax
IN
16A
50Hz
L1 N1
NTC
Zone Valve
G/Y BR BL GR
M
0
N L A B C A B C
AC
230V
Imax
IN
16A
50Hz
L1 N1
NTC
Wiring Figure:
2.1 2 Receiver’s wiring.
Contacts:
N L A B C A B C
AC
230V
Imax
IN
16A
50Hz
L1 N1
NTC
230VAC 50Hz<16A β3380 R25 10KΩ= °C=
Wiring with AC230V power supply in NTC sensor terminals will destroy
the receiver!
Thermostat kit do not contains external temperature sensor NTC terminals.

06
2. System Installation
81.5mm
81.5mm
4mm
2.2.1 Activate Batteries
2.2.2 Install Thermostat
This thermostat could be desk-stand if open the back support, you just need to place it on
any flat surface allows to receive RF signal.
If you want to hang it on the wall, use the template provided.
Drill two holes in the wall and tighten the screws, ensuring two holes’ distance is 81.5mm;
then, fix the thermostat’s back cover by putting it over the screw head.
Remove the battery cover Insert batteries, ensure
correct orientation Close the battery cover
2.2 Activate Batteries and Install Thermostat
07
2. System Installation
2.3 System Check
2.3.1 RF Signal Pairing
The room thermostat has already been pre-bound with receiver
in kit PTC10/PTR16 when delivery. You may directly move to RF
communication test, please refer to 2.3.2.
i
A. RF signal pairing between room thermostat and receiver
1 Preparation: thermostat and receiver should be powered/wired correctly, make sure the
visible distance between thermostat and receiver is not more than 5 meters.
2 Start receiver s RF paring mode by hold-pressing the LEARN button until its light
flashing.
’
3 Press OVERRIDE Ⅰ to pair with thermostat; when light of OVERRIDE is flashing, it
means OVERRIDE Ⅰ is ready to pair with thermostat next.
Ⅰ
(3-1)Long press to enter Menu Selection, select by pressing or
when are flashing, press to enter RF pairing interface.
4 Thermostat send pairing command with receiver:

08 09
2. System Installation
1 Automatically pairing thermostat with gateway by App on mobile phone
B. RF signal pairing between room thermostat and gateway this is only for Wi-Fi
thermostat)
(
(1-1)Open the App. which already connected with gateway(how to add a gateway on
App. please refer to gateway’s manual for details), choose Add Thermostat from the
interface;
(3-2)When is flashing on the screen’s left side, press to send the pairing
command with receiver;
Pairing success if flashing on screen’s right side, pairing failed if E01 or E02 is
flashing on screen’s right side, in this case, you need to send the paring command with
receiver by pressing once again until pairing success.
4 Exit pairing mode: Exit pairing mode by pressing LEARN button; thermostat s HOME
page can be returned by keep pressing .
’
5 Once thermostat and receiver was paired successfully, their RF communication started
normally, will show up on the top right corner of thermostat’ s screen.
succeed
failed
2. System Installation

(1-2)Add thermostat by scanning it's QR code or typing MAC ID manually.
(1-3)Pairing process between thermostat and gateway might take about 1 minute. Once
thermostat is paired with gateway successfully, will show up on the top right corner
of thermostat’s screen; App. interface also show up the added thermostat’s information.
10
2. System Installation 11
2. System Installation
2 Manually paring thermostat with gateway
(2-1)Preparation: Powered gateway correctly by plug-in socket, the LED on gateway
will be blinking rapidly (LED blinking rapidly means no connection between gateway and
server).
(2-2)Start gateway’s pairing mode by hold pressing until its LED is blinking slowly.
(2-3)Thermostat send pairing command with gateway.

(2-3-1)Long press to enter Menu Selection, when are flashing,
press to enter RF pairing interface.
(2-3-2)On RF pairing interface, select by pressing on or until flashing
show up on screen’s left side, press to send thermostat’s paring commend
to gateway; pairing success if flashing on screen’s right side, pairing failed if E01
or E02 is flashing on screen’s right side, in this case, you need to send the paring
command with gateway by pressing once again until pairing success.
868MHz is E11 error and 433MHz is E01 error.
succeed
failed
(2-4)Gateway is still under paring mode even one thermostat's paring succeed, if you
had more thermostats need to be paired, you may continue to pair them with gateway
manually. (1 gateway could RF communicate with 10 thermostats at one time).
(2-5)Exit pairing mode by hold-pressing until the LED recover to its status before
pairing.
(2-6)Once thermostat and gateway was paired successfully, their RF communication
started normally, will show up on the top right corner of thermostat’s screen; App.
interface also show up the added thermostat’s information.
12
2. System Installation 13
2. System Installation

14
2. System Installation 15
2. System Installation
2.3.2 RF communication test
To make sure RF communication between thermostat and receiver, thermostat and
gateway before using them regularly, you should take a RF communication test.
1 RF communication test between thermostat and receiver
Enter RF Communication Test by long pressing , when show up on screen’s
left side, presse to test RF communication between thermostat and receiver; test
result is good if show up on screen’s right side, otherwise, will show
up on screen’s right side, in this case, you need relocate the thermostat and do the test
once again.
2 RF communication test between thermostat and gateway
Enter RF Communication Test by long pressing , when show up on screen’s
left side, press to test RF communication between thermostat and gateway; test
result is good if show up on screen’s right side, otherwise, will show
up on screen’s right side, in this case, you need relocate the thermostat and do the test
once again.
good
bad
good bad

16 17
3. Operation Thermostat
1
there is a flashing , then enter Clock Setting by pressing .
Enter Menu Selection by long pressing , select by until
3.1 Clock Setting
Clock setting should be done if thermostat was used for the first time or after batteries
changed; automatically clocking setting will be done if thermostat was connected with
Internet via Gateway.
2
Area, press to select current year and press to set.
Firstly set Year after entered Clock Setting, when appeared on Temperat-ure
6 Back to the last setting menu by pressing .
4
date and press to set.
When appeared on Temperature Area, press to select current
5 When clock setting is flashing on Time Area, press to select current
time and press to confirm.
Hour Minute
3
month and press to set.
When appeared on Temperature Area, press to select current
3. Operation Thermostat
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels POER Thermostat
Manuels Thermostat populaires d'autres marques

EWELLY
EWELLY EW-181 Manuel utilisateur

Prolon
Prolon T1100 Instructions d'installation

Computherm
Computherm Q20 Manuel utilisateur

Heatmiser
Heatmiser neoStat Manuel utilisateur

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manuel utilisateur

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manuel utilisateur