PMA Digital 280-1 Manuel utilisateur

PMA Prozeß- und Maschinen-Automation GmbH
Digital 280-1
digital indicator
Digita
l
280-1
Di
g
ital 280-1
Operating manual
English
9499-040-67311
Valid from: 8415

© PMA Prozeß- und Maschinen-Automation GmbH •Printed in Germany
All rights reserved.
No part of this document may be reproduced or published in any form or by any means
without prior written permission from the copyright owner.
A publication of PMA Prozeß- und Maschinen Automation
P.O.Box 310229
D-34058 Kassel
Germany
ûBlueControl
More efficiency in engineering,
more overview in operating:
The projecting environment for the BluePortcontrollers
Description of symbols:
gGeneral information
aGeneral warning
lAttention: ESD sensitive devices
ATTENTION!
Mini Version and Updates on
or on PMA-CD
www.pma-online.de

Digital 280-1 3
Content
1Mounting ..............................5
2Electrical connections .......................7
2.1 Connecting diagram .........................7
2.2 Terminal connection.........................7
3Operation .............................11
3.1 Front view .............................11
3.2 Behaviour after power-on .....................11
3.3 Operating level ...........................12
3.3.1 Min/max function ............................12
3.3.2 Tare function ..............................13
3.3.3 Sample&hold amplifier .........................13
3.3.4 O2measurement .............................14
3.3.5 Extended operating level ........................15
3.3.6 Alarm handling .............................16
3.4 Maintenance manager / Error list .................17
4Controller .............................19
4.1 Operation..............................19
4.2 Control parameters .........................19
4.3 Self-tuning .............................20
4.3.1 Self-tuning start ( Ù+È)......................20
4.3.2 Self-tuning cancellation ........................20
4.3.3 Acknowledgement procedures in case of unsuccessful self-tuning . 21
4.3.4 Examples for self-tuning attempts ..................22
4.3.5 (controller inverse, heating or heating/cooling) ...........22
4.4 Manual tuning ...........................22
4.5 Operating structure.........................24
5Configuration level ........................25
5.1 Configuration survey........................25
5.2 Configuration ...........................26
5.3 Configuration examples ......................34
5.3.1 On-Off controller / Signaller (inverse) .................34

4 Digital 280-1
5.3.2 2-point controller (inverse) .......................35
5.3.3 Continuous controller (inverse) .....................36
5.3.4 Digital 280-1 with measured value output ...............37
6Parameter setting level ......................39
6.1 Parameter survey ..........................39
6.2 Parameter..............................40
6.3 Input scaling ............................41
6.3.1 Input Inp ...............................41
7Calibration level .........................43
7.1 Offset correction ..........................43
8BlueControl ............................47
9Versions ..............................49
10 Technical data ..........................51
11 Safety hints ............................57
11.1 Resetting to factory setting.....................58
12 Notes ................................59

1Mounting
Safety switch:
For access to the safety switches, the indicator must be withdrawn from the hou-
sing. Squeeze the top and bottom of the front bezel between thumb and forefinger
and pull the controller firmly from the housing..
10V i mA/Pt right 1 Current signal / Pt100 / thermocouple/mV at InP
left Voltage signal (V) at InP
Loc open Access to the levels is as adjusted by means of BlueControl
(engineering tool) 2
closed 1 all levels accessible wihout restriction
1Factory setting 2Default setting: display of all levels
suppressed, password PASS =OFF
aSafety switch 10V imA/Pt always in position left or right. Leaving the
safety switch open may lead to faulty functions!
lCaution! The unit contains ESD-sensitive components.
Mounting
Digital 280-1 5
or
*
Ü
*
Ü
%
max.
95% rel.
max. 60°C
0°Cmin.
Loc 10V imA/Pt
Loc 10V mA/Pt
security switch
1..10
(0.04..0.4")
48 (1.89")
96 (3.78")
10 (0.4")
118 (4.65")
92 +0,8
(3.62" )
+0.03
min.48
(1.89")
45
+0,6
(1.77" )
+0.02
F
FUNC
ADA
OUT1
OUT2
OUT3
ERR
min max
Digital 280-1

2Electrical connections
2.1 Connecting diagram
* Safety switch mA iV in position left
gThe indicator is provided with screw terminals from 0,5 to 2,5mm².
2.2 Terminal connection
Power supply connection 1
See chapter 10 "Technical data"
Connection of input INP1 2
Input for variable x1 (process value)
athermocouple
bresistance thermometer (Pt100/ Pt1000/ KTY/ ...)
cpotentiometer
dcurrent (0/4...20mA)
evoltage (-2,5...115/-25...1150/-25...90/ -500...500mV)
fvoltage (0/2...10V/ -5...5V)
Electrical connections
6 Connecting diagram Digital 280-1
U
Logic
di2
di3
UT
Option
RXD-B
GND
RXD-A
TXD-B
TXD-A
RS485 RS422
Modbus RTU
RGND
DATA B
DATA A
L
N
90...250V
24V AC/DC
di1
INP1
OUT3
OUT2
OUT1
1
7
5
8
6
9
10
11
12
13
14
15
4
3
2
1
7
5
8
6
9
10
11
12
13
14
15
4
3
(2)
17
16
7
8
9
di1
V*
-
+
mA
-
+
100%
0
+
mV
-
+
1
3
4
5
2
6
7
6
abcd e
f
8
ghi

Connection of input di1 4
Digital input, configurable as switch or push-button
Connection of outputs OUT1/2 5
Relay outputs 250V/2A normally open with common contact connection
Connection of output OUT3 6
glogic (0..20mA / 0..12V)
hvoltage (0/2...10V)
icurrent (0/4...20mA)
itransmitter power supply
Connection of inputs di2/3 7(option)
Digital inputs (24VDC external), galvanically isolated, configurable as switch or
push-button
Connection of output UT8(option)
Supply voltage connection for external energization
Connection of bus interface 9(option)
RS422/485 interface with Modbus RTU protocol
aIf UTand the universal output OUT3 is used there may be no external galvanic
connection between measuring and output circuits!
Electrical connections
Digital 280-1 Terminal connection 7
Option
+24VDC
5mA
5mA
0V
1
2
3
K
+
-
+
-
+
-
17,5V
22mA
OUT3
J
J
x
1
7
5
8
6
9
10
11
12
13
14
15
4
3
5
1
7
5
8
6
9
10
11
12
13
14
15
4
3
(2)
17
16
78 di2/3, UT2-wire transmitter supply
1
2
3
K
+
-
+
-
13V
22mA
7
8
9
10
11
12
13
14
15
6OUT3 transmitter supply

* Interface description Modbus RTU in seperate manual: see page .
Electrical connections
8 Terminal connection Digital 280-1
12
13
14
15
17
(16)
11
12
13
14
15
10
12
13
14
15
17
(16)
11
12
13
14
15
10
12
13
14
15
17
(16)
11
12
13
14
15
RGND RGND RGND
RT
interface
converter
RS485-RS232
PC
DATA A
DATA B
DATA A
DATA B
DATA A
DATA B
J
max. 1000m
twisted pair
10
RT
RGND optional connection
R = line resistanceT
12
13
14
15
17
16
10
11
12
13
14
15
10
11
12
13
14
15
10
11
12
13
14
15
12
13
14
15
17
16
12
13
14
15
17
16
9RS485 interface (with RS232-RS485 interface converter) *
3
4
7
5
8
6
9
10
+
_
SSR
+
_
SSR
+
_
SSR
serial installation
7
8
9
Logic
4V
4V
4V
12V
I=22mA
max
7
8
9
7
8
9
parallel installation
+
_
SSR
+
_
SSR
I=22mA
max
12V
7
5
8
6
9
10
4
3
7
8
9
6OUT 3 als Logikausgang mit Solid-State-Relais (Reihen- und Parallel-Schaltung)

Connecting exampleDigital 280-1:
aCAUTION:
Using a temperature limiter is recommendable in systems where
overtemperature implies a fire hazard or other risks.
Electrical connections
Digital 280-1 Terminal connection 9
1
2
3
4
7
5
8
6
9
10
11
12
13
14
15
Logic
+
_
L1
L2
N1
N2
fuse
1
2
3
4
7
5
6
fuse
TB 40-1
temperature limiter
1
Digital 280-1
fuse
SSR
reset-
switch
contactor
heating
1TB 40-1 temperature limiter
standard-version (3 relay)
TB40-100-0000D-000
further versions on demand
r
++
1
7
5
8
6
9
10
11
12
13
14
15
4
3
2
1
7
5
8
6
9
10
11
12
13
14
15
4
3
2

3Operation
3.1 Front view
1measured value display
2statuses of switching outputs OuT.1... 3(or alarm statuses)
3lit with self-tuning activated
4lit with tare or sample & hold function activated
5lit with entry in the error list
6function-key
7down-key
8up-key
9enter-key: calls up extended operating level/ errorlist
0pc connection for BlueControl (engineering-tool)
gThe measured value is displayed as standard. At parameter setting, configuration,
calibration level and at the extended operating level, the display changes
cyclically between parameter name and parameter value.
3.2 Behaviour after power-on
After supply voltage switch-on, the unit starts with the operating level.
The unit is in the condition which was active before power-off.
If KS4x-1 was in manual mode before power-off, the controller starts with cor-
recting value Y2 after switching on again.
Operation
10 Front view Digital 280-1
F
FUNC
ADA
OUT1
OUT2
OUT3
ERR
min max
Digital 280-1
2
3
4
5
6
1
0
987
Table des matières
Autres manuels PMA Écran tactile
Manuels Écran tactile populaires d'autres marques

IBASE Technology
IBASE Technology ASTUT-152-RE1S Manuel utilisateur

YASKAWA
YASKAWA TP 610C Manuel utilisateur

B&R
B&R Power Panel C Series Manuel utilisateur

Beijer Electronics
Beijer Electronics X2 control Manuel utilisateur

AXIOMTEK
AXIOMTEK GOT321W-521 Manuel utilisateur

TRIDONIC.ATCO
TRIDONIC.ATCO x-touchBOX Manuel utilisateur