Paradox CR-R885-BL Manuel utilisateur

PIN and Proximity Reader
For Access Control Systems
(CR-R885-BL)
Installation and Operating Instructions
V1.1
We hope this product performs to your complete satisfaction. Should you have
any questions or comments, please visit www.paradox.com and send us your
comments.


Proximity Reader 1
TABLE OF CONTENTS
Selecting an Installation Site: .......................2
Mounting and Wiring....................................2
Mounting on Metal Surfaces..........................3
Technical Specifications................................3
Feedback ...................................................5
Programming..............................................6
Card/Code Options ......................................7
Keypad Communication Format.....................7
Transfer Limit for 4-bits Buffered Format........8
Display on Card Read...................................9
Keypad Lockout ..........................................9
26-bit Wiegand Card Family Code Setting.....10
Reader’s Interface.....................................10
Check-in Supervision.................................11
Buzzer Setting..........................................11
Face Light Intensity...................................12
Face Light Operation..................................12
Face Light Colour ......................................12
Changing the Installer Code........................13
Panic Alarm..............................................13
Resetting to Default...................................13
Card Presentation Test...............................14
Warranty .................................................15

2 Installation Manual
INSTALLATION
For the reader to function correctly with the access
control system, some programming may be
required in the controller orcontrol panel of the host
system. For further instructions, refer to the
appropriate manual. Only explanations directly
concerning the reader’s programming will be
included in this manual.
SELECTING AN INSTALLATION SITE:
•Avoid wiring the reader’s cables in the same
conduit as AC power cables, lock power or signal
wiring.
•Reader wiring must remain a minimum of 30cm
(12in) away from other wiring, such as wiring for
AC power, computer data, telephones, electric
locks, etc.
•Avoid sites within 1.1m (3.5ft) of computer
monitors or CRTs.
•Avoid sites near sources of broad spectrum EMI
noise, such as motors, pumps, generators, DC to
AC converters, AC switching relays, power
supplies, and light dimmers.
•Avoid sites near potential sources of RF signals,
such as cellular phones, two-way radios, etc.
MOUNTING AND WIRING
After selecting a site for the reader, use the
mounting plate as a guide to drill two holes to
secure the mounting plate and a hole for the cable
0.95cm to 2.54cm (0.375in to 1in) wide. Place a
grommet around the edge of the hole for the cable.
Prepare the reader’s cable by cutting the cable

Proximity Reader 3
jacket back 3.175cm (1.25in) and stripping the
wires back 0.635cm (0.25in). Splice the reader’s
wires with a recommended cable wire. Route the
cable to the controller and connect as shown in
Figure 1: Connection Drawing on page 5.
MOUNTING ON METAL SURFACES
Although the read range may slightly decrease, the
reader can be mounted on metal. However, do not
box in or surround the card reader with any kind of
metal. If the reader must be installed in a metal
enclosure, ensure that the face of the card reader is
not covered and that at least 1.6" (4cm) remain
between the card reader and the metal on all sides
of the card reader.
TECHNICAL SPECIFICATIONS
Input Voltage: Typical: 13.8Vdc, min.: 11.0Vdc,
max: 14.5Vdc
Input Current: Typical: 65mA @ 12.5Vdc, with
card: 105mA
Consumption: Typical: 812mW @ 12.5Vdc, with
card 1.31mW
Frequency: Exciter Field: 125KHz Pulse
Modulated, receive low:
12.500KHz, Receive high:
15.625KHz
Operating Temp: -25°C (-13°F) to +65°C (+149°F)
Output formats: Reader: 26- and 37-bit Wiegand
Keypad: 8-, 26- and 37-bit
Wiegand, 4-bit with or without
parity, and 4 bits buffered with or
without parity
Cable Distance: 152.4m (500ft.)

4 Installation Manual
Suggested Cables: 22AWG, 0.8mm, Multi-conductor,
Alpha 5196, 5198
18AWG, 1.2mm, Multi-conductor,
Alpha 5386, 5388
Belden 9553, 18AWG, 6-
conductor, stranded w/overall
shield
Indicators: Beeper, red LED, green LED, blue
or green Face Light
Weight: 280g (9.8 oz.)
Material: Black, UV resistant, ABS plastic
Dimensions: 99.5mm (5.75in.) x 118.5mm
(2in.) x 19.5mm (1in.)
Approvals: Compliant to all EU and
EFTA countries except Greece
according to RTT&E directives.

Proximity Reader 5
Figure 1: Connection Drawing
FEEDBACK
Visual Feedback: When information is entered on
the reader’s keypad, the red and/or green LEDs will
flash, remain constant or extinguish depending on
the operation.
Access Control

6 Installation Manual
Confirmation Beep: When an operation is
successfully entered, the reader emits a rapid series
of beep tones (“beep-beep-beep-beep-beep”).
Rejection Beep: When the system reverts to a
previous status or an operation is incorrectly
entered, the reader emits one long beep tone
(“beeeeeeeeeep”).
PROGRAMMING
Ensure that corresponding programming is
completed in the control panel or controller
connected to the reader.
To Program:
1.Press and hold the [CLEAR]key for 4 seconds.
The reader emits a confirmation beep and the
green LED illuminates.
2.Enter the [INSTALLER CODE]. Press the
[ENTER]key.
(default:000000) Reader emits a confirmation
beep and the green LED flashes.
3.Enter the 3-digit [SECTION]. Press the
[ENTER]key.
Reader emits a confirmation beep and the
green LED stops flashing.
4.Enter the required [DATA]. Press the [ENTER]
key.
The reader emits a confirmation beep and the
green LED flashes.

Proximity Reader 7
CARD/CODE OPTIONS
Section [001] - Default: [3]
The reader can also function as a keypad.
KEYPAD COMMUNICATION FORMAT
Section [002] - Default: [1]
The reader must use the same keypad
communication format as the controller.
5.To program another section, repeat steps 3
and 4. To exit programming mode, press and
hold the [CLEAR]key for 4 sec.
The reader emits a rejection beep and the
green LED extinguishes.
Enter Description
[0] Keypad and reader disabled.
For programming only.
[1] Reader only enabled. A user must
present a valid card to the reader for
Access Granted.
[2] Keypad only enabled. A user must enter
a valid code on the keypad for Access
Granted.
[3] Keypad and reader enabled. A user
must present a valid card and enter a
valid code for Access Granted.
Enter Description
[0] 8-bit Wiegand (Motorola ARK).
[1] 26-bit Wiegand (also see section
[006]).
[2] 37-bit Wiegand

8 Installation Manual
Note that BCD is not supported.
TRANSFER LIMIT FOR 4-BITS BUFFERED
FORMAT
Section [003] - Default: [00]
This feature sets the number of digits retained in
memory before the data is sent tothe controller. For
example, if section [003] is set at 05, the reader
will transmit once five digits are entered on the
keypad.
This feature only applies when the format
programmed in Section [002] is set for
Option [5]: 4 bits buffered without parity or
Option [6]: 4 bits buffered with parity.
[3] 4 bits without parity.
[4] 4 bits with parity.
[5] 4 bits buffered without parity
(also see section [003]).
[6] 4 bits buffered with parity (also see
section [003]).
Enter Description
[01] to [11] If section [002] is Option [5]:
4 bits buffered without parity.
[01] to [10] If section [002] is Option [6]:
4 bits buffered with parity.
Table des matières