Optika Italy C-HP4SC Manuel utilisateur

Model
C-HP4
C-HP4SC
HDMI Cameras – H Series
INSTRUCTION MANUAL
Ver. 1.0 2023

Page 2
1. Warning 3
2. Safety Information 3
3. Package content 4
3.1 C-HP4 4
3.2 C-HP4SC 4
4. Unpacking 5
5. Intended use 5
6. Symbols and conventions 5
7. Instrument description 6
7.1 Camera control panel 6
7.2 HDMI monitor 6
8. Assembling 7
8.1 C-HP4SC 7
8.2 Parfocality adjustment 9
9. C-HP4 Basic features 10
9.1 Quick Instructions for C-HP4 camera 10
9.1.1 HDMI Mode 10
9.1.2 USB Mode 10
10. C-HP4 User Interface (UI) and its Functions 11
10.1 The Camera Control Panel 12
10.2 The Measurement Toolbar 13
10.3 Camera calibration 15
10.4 Icons and Functions of the Camera Control Toolbar 17
10.4.1 Setting > Measurement 17
10.4.2 Setting>Magnication 18
10.4.3 Setting > Image Format 18
10.4.4 Setting > Video 19
10.4.5 Setting > Storage 20
10.4.6 Setting > Files 20
10.4.7 Setting > Language 21
10.4.8 Setting > Miscellaneous 22
11. Micrometric Slide M-005 23
Equipment disposal 24
Table of Contents

Page 3
1. Warning
This device is a scientic precision instrument designed to last for many years with a minimum of maintenance. It is built
to high optical and mechanical standards and to withstand daily use. We remind you that this manual contains important
information on safety and maintenance, and that it must therefore be made accessible to the instrument users. We decline
any responsibility deriving from incorrect instrument use uses that does not comply with this manual.
2. Safety Information
Avoiding Electrical Shock
Before plugging in the power supply, make sure that the supplying voltage of your region matches with the operation voltage
of the equipment and that the lamp switch is in o position. Users should observe all safety regulations of the region. The
equipment has acquired the CE safety label. However, users have full responsibility to use this equipment safely. Please
follow the guidelines below, and read this manual in its entirety to ensure safe operation of the unit.

Page 4
3. Package content
① Camera
② HDMIcable
③ USB2.0cable
④ Wirelessmouse
⑤ Micrometricslide
⑥ SDcard16GB
⑦ Powersupply
①
②
③
④
⑤
⑥
⑦
3.1 C-HP4
3.2 C-HP4SC
① Camerawithxingplate
② Camerapowersupply
③ Wirelessmouse
④ HDMImonitorwithxingplate
⑤ Monitorpowersupply
⑥ Type“C”L-adapter
⑦ HDMI-to-miniHDMIL-adapter
⑧ HDMIcable
⑨ USB2.0cable
➉ SDcard16GB
⑪ Micrometricslide
③
⑥⑦
⑧
⑪
①
②
④
⑨➉
⑤

Page 5
4. Unpacking
The device is housed in a moulded Styrofoam container. Remove the tape from the edge of the container and lift the top half
of the container. Take some care to avoid that the optical items (objectives and eyepieces) fall out and get damaged. Using
both hands (one around the arm and one around the base), lift the device from the container and put it on a stable desk.
Do not touch with bare hands optical surfaces such as lenses, lters or glasses. Traces of grease or other
residuals may deteriorate the nal image quality and corrode the optics surface in a short time.
5. Intended use
Standard models
For research and teaching use only. Not intended for any animal or human therapeutic or diagnostic use.
IVD Models
Also for diagnostic use, aimed at obtaining information on the physiological or pathological situation of the subject.
6. Symbols and conventions
The following chart is an illustrated glossary of the symbols that are used in this manual.
CAUTION
This symbol indicates a potential risk and alerts you to proceed with caution.
ELECTRICAL SHOCK
This symbol indicates a risk of electrical shock.

Page 6
7. Instrument description
① USBmouseconnector
② USB2.0connector
③ HDMIconnector
④ ON-OFFbutton
⑤ SDcardslot
⑥ Powersupplyplug
⑦ LEDindicator
①②③
④
⑤
⑥
⑦
7.1 Camera control panel
7.2 HDMI monitor
HEADPHONE
MENU DIAL
ON/OFF BUTTON HDMI PORT ①
TYPE C PORT ②
TYPE C PORT ③
MICRO USB PORT ④
① HDMIcameraconnection
② VideoDisplay/Audio/TouchControl
③ PowerSupply/USB3.0port
④ Keyboard/Mouseconnection
NOTE:Whenusingthemonitorinthisconguration,theHeadphone,TypeC②and Micro USB ④ports are not
used.

Page 7
8. Assembling
8.1 C-HP4SC
1. Using the supplied screws, join the xing plate mounted on
the camera ① and the xing plate mounted on the monitor
②. (Fig. 1)
FFig. 2ig. 2
FFig. 1ig. 1
①
③
②
FFig. 3ig. 3
④
⑤
FFig. 4ig. 4
2. Screw the “C” mount adapter ③ to the camera ④. (Fig. 2)
3. Loosen the clamping screw ⑤ on the trinocular port and
remove the dust cap ⑥. (Fig. 3)
⑥
4. Insert the round dovetail of the “C” mount into the empty hole
of the trinocular port, then tighten the clamping screw ⑤.
(Fig. 4)
⑤

Page 8
5. Plug the USB mouse receiver in the “USB MOUSE” port Ⓐ
on the camera. (Fig. 5)
FFig. 5ig. 5
FFig. 6ig. 6
Ⓐ
Ⓑ①
②
6. Connect the cable with the HDMI side ① to the provided HD-
MI-HDMI L-adapter ②. (Fig. 6)
7. Connect the HDMI L-adapter to the “HDMI” port Ⓑ on the
camera.
FFig. 7ig. 7
FFig. 8ig. 8
Ⓒ
Ⓓ
8. Plug mini HDMI cable to the mini HDMI port Ⓒplaced on the
right side of the monitor. (Fig. 7)
9. Insert the SD card into “SD” slot Ⓓ for saving captured imag-
es and recorded videos. (Fig. 8)

Page 9
FFig. 9ig. 9
FFig. 10ig. 10
Ⓕ
Ⓔ
③④
10. Plug the monitor power supply connector ③in the provided
“L” adapter ④. (Fig. 9)
11. Plug the “L” adapter in the “Type C” port Ⓔ placed on the
right side of the monitor.
12. Plug the power supply to the wall outlet.
13. Insert the camera power supply jack in the “DC12V” socket
Ⓕ. (Fig. 10)
14. Plug the power supply to the wall outlet.
FFig. 11ig. 11
8.2 Parfocality adjustment
In order to have the same focus when observing the specimen
through the eyepieces and on the monitor, please check that the
microscope is properly set and follow the instructions below.
1. Use a low power objective and focus the specimen using the
microscope focus knobs.
2. Switch to the highest dry objective available on the micro-
scope (40x or 60x) and focus the specimen again.
3. Turn on the live-view on the camera, without changing the
focus on the microscope.
4. While observing the image on the monitor, adjust the focus
by turning the knurled knob on the C-mount adapter. (Fig. 11)

Page 10
9. C-HP4 Basic features
C-HP4 is a multiple interfaces (HDMI + USB2.0 + SD card) CMOS camera.
HDMI and USB2.0 are used as the data transfer interface to HDMI display or computer.
• For HDMI output, the Camera Control Panel + Measurement Toolbar and Camera Control Toolbar are overlaid on the
HDMI screen when the mouse move to the related region.
In this case, the USB mouse can be used to set the camera, browse and compare the captured image, play the video
and perform the measurement.
• For USB output, connect computer with USB connection to transfer video in real time.
From here the ProView software can control each camera function.
9.1 Quick Instructions for C-HP4 camera
You can use the C-HP4 camera in 2 dierent ways. Each application requires dierent hardware environment.
9.1.1 HDMI Mode
1. Plug the HDMI cable into the HDMI port ③ to connect the C-HP4 camera to HDMI display.
2. Plug the USB mouse into USB Mouse port ① to get control of the camera by using built-in software HDMI pro.
3. Plug 12V/1A power adapter into DC 12V slot ⑥ to supply power for the camera. The LED Indicator ⑦ will turn into red.
4. Insert SD card into SD Card slot ⑤ for saving captured images and recorded videos.
5. Press ON/OFF Button ④ to turn on the camera. The LED indicator will turn into blue.
6. Move mouse cursor to the left side of the video window, a Camera Control Panel will appear. It includes Manual/ Auto-
matic Exposure, White Balance, Sharpness and other functions, please refer to 10.1 for details.
7. Move mouse cursor to the bottom of the video window and a Camera Control Toolbar will appear. Operations like Zoom
In, Zoom Out, Flip, Freeze, Cross Line, Comparison and so on can be achieved. Please refer to 10.3 for details.
8. Move mouse cursor to the upper side of the video window, a Measurement Toolbar with calibration and other measure-
ment tools will appear, please refer to 10.2 for details. The measurement data can be output with *.CSV format.
9.1.2 USB Mode
1. Plug the USB cable provided with the camera into USB2.0 ② to connect the C-HP4 camera to the computer.
2. Plug 12V/1A power adapter into DC 12V slot ⑥ to supply power for the camera. The LED Indicator ⑦ will turn into red.
3. Press ON/OFF button ④ to turn on the camera. The LED indicator will turn into blue.
4. Start the ProView software.
5. Clicking the camera name in the camera list starts the live video.
• NOTE:WhentheUSBcableandthemousearepluggedintothecameraatthesametime,theUSBcablehas
priorityandthemouseisnotavailable;whentheUSBcableisunplugged,themousecanbeusednormally.
Ce manuel convient aux modèles suivants
2
Table des matières
Langues :
Autres manuels Optika Italy Appareil photo numérique

Optika Italy
Optika Italy H Series Manuel utilisateur

Optika Italy
Optika Italy OPTIKAM B1 Manuel utilisateur

Optika Italy
Optika Italy C-B Series Manuel utilisateur

Optika Italy
Optika Italy SZP Series Manuel utilisateur

Optika Italy
Optika Italy C-HA Manuel utilisateur

Optika Italy
Optika Italy H Series Manuel utilisateur

Optika Italy
Optika Italy H Series Manuel utilisateur

Optika Italy
Optika Italy H Series Manuel utilisateur

Optika Italy
Optika Italy H Series Manuel utilisateur

Optika Italy
Optika Italy C-D Series Manuel utilisateur