Olympus TH4 Manuel utilisateur

INSTRUCTIONS
TH4
HALOGEN LAMP POWER SUPPLY UNIT
This instruction manual is for the Olympus TH4 Halogen Lamp Power Supply Unit. To ensure the safety and
obtain optimum performance and to familiarize yourself fully with the use of this unit, we recommended
that you study this manual thoroughly before operating the unit. Retain this instruction manual in an easily
accessible place near the work desk for future reference.
A X 9 9 8 2
Optical Microscope Accessory

In accordance with European Directive on Waste Electrical and Electronic Equipment, this symbol indicates that the
product must not be disposed of as unsorted municipal waste, but should be collected separately.
Refer to your local Olympus distributor in EU for return and/or collection systems available in your country.
For Korea only
B급 기기 (가정용 방송통신기자재)
이 기기는 가정용(B급) 전자파적합기기로서 주로 가정에서 사용하는 것을
목적으로 하며, 모든 지역에서 사용할 수 있습니다.
This product is applied with the requirements of standard IEC/EN61326-1 concerning electromagnetic compatibility.
- Immunity Applied to industrial and basic environment requirements.
NOTE: This product has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the product is operated
in a commercial environment. This product generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this product in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
FCC WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the product.

TH4
CONTENTS
PROPER SELECTION OF THE POWER SUPPLY CORD....................................................................................................................... 14-17
8 LAMP HOUSING INSPECTION SHEET 18,19
IMPORTANT — Be sure to read this section for safe use of the equipment. — 1-3
1 NOMENCLATURE 4
2 COMPATIBLE HALOGEN LAMP HOUSING 5
3 ASSEMBLY 6
4 OPERATION 7
5 SPECIFICATIONS 8
6 CONTROL VIA THE REMOTE CONNECTOR 9-12
7 TROUBLESHOOTING GUIDE 13

1
10. The standard service life of the lamp housing is eight (8) years of use or 20,000 hours of total power ON period, whichever
is the shorter period.
For details, see Inspection Sheet on pages 18, 19.
IMPORTANT
This power supply unit is only for use with Olympus halogen lamp housings.
SAFETY PRECAUTIONS
1. A power supply is a precision instrument. Handle it with care and avoid subjecting it to sudden or severe impact.
2. Do not use the power supply where it is subjected to direct sunlight, high temperature and humidity, dust or vibrations.
3. For operation environmental conditions, see chapter 5, “SPECIFICATIONS” on page 8.
4. Always use the power cord provided by Olympus. If no power cord is provided, please select the proper power cord by
referring to the chapter “PROPER SELECTION OF THE POWER SUPPLY CORD” at the end of this instruction manual.
5. Always set the main switch on the power supply unit to “ ” (OFF) before connecting the power cord to the wall outlet.
6. This power supply is air-cooled so its surfaces become hot during operation. When installing it, leave spaces of more than
10cm around it. Also make sure to distribute cables away from the power supply.
7. To avoid potential shock hazard, make sure that the power cord is properly grounded.
8. Be sure to set the main switch to “ ” (OFF) and unplug the power cord before replacing the halogen lamp bulb.
9. The surfaces of the lamp housing will become extremely hot. When installing the lamp housing, be sure to allow ample free
spaces around and in particular above and below the lamp housing.

TH4
2
Safety Symbols
Symbol Meaning
Before use, carefully read the instruction manual. Improper use could result in personal injury to
the user and/or damage to the equipment.
Indicates that the main switch is ON.
Indicates that the main switch is OFF.
1Maintenance and Storage
1. Do not attempt to use organic solvents to clean the power supply unit. To clean it, use a lint-free, soft cloth slightly
moistened with a diluted neutral detergent.
2. Never attempt to disassemble any part of the power supply unit.
The following symbols are found on the power supply unit. Study the meaning of the symbols and always use the
equipment in the safest possible manner.
If the power supply unit is used in a manner not specified by this manual, the safety of the user may be imperiled. In
addition, the equipment may also be damaged. Always use the system as outlined in this instruction manual.
The following symbols are used to set off text in this instruction manual.
: Indicates that failure to follow the instructions in the warning could result in bodily harm to the
user and/or damage to equipment (including objects in the vicinity of the equipment).
# : Indicates that failure to follow the instructions could result in damage to equipment.
} : Indicates commentary (for ease of operation and maintenance).
2Caution

3
3Intended use
This instrument has been designed to be used to observe magnified images of specimens in routine and research
applications.
Do not use this instrument for any purpose other than its intended use.

TH4
4
NOMENCLATURE
Power Supply Unit TH4
Main switch
: ON
: OFF
Hand Switch TH4-HS (Optional)
Brightness control knob
Extension Cord U-RMT (Optional)
Compatible halogen lamp housing
Brightness control knob
POWER LED
REMOTE LED
Lamp ON-OFF switch
Extension cord (U-RMT)
Power supply unit (TH4)

5
COMPATIBLE HALOGEN LAMP HOUSING
Power Supply Unit
TH4
For halogen lamp housing
Halogen Lamp Housing
· U-LH100-3
· U-LH100L-3
· IX-ILL100LH
Any lamp housings other than described above
cannot be used with TH4.

TH4
6
ASSEMBLY
1Connecting the Cables and Cords (Fig. 1 & 2)
The cables and cords are vulnerable when bent or twisted. Never
subject them to excessive force.
Make sure that the main switch is set to “ ” (OFF) before connecting
cables and power cord. Otherwise equipment failure may result.
1. Insert the hand switch plug @ into the connector ².
2. Insert the lamp housing plug ³ into the connector |.
Always use the power cord provided by Olympus. If no power cord is
provided with the microscope, please select the proper power cord
by referring to chapter “PROPER SELECTION OF THE POWER SUP-
PLY CORD” at the end of this instruction manual.
3. Insert the power cord plug ƒ into the connector ….
4. Insert the power cord plug † into the wall power outlet ‡.
The power cord should be connected to a grounded, 3-conductor
power outlet. If the power outlet is not grounded properly, Olympus
can no longer warrant the electrical safety performance of the equip-
ment.
If a cable or the power cord comes in contact with the lamp socket or
the surroundings, the cable or cord may melt down, causing electric
shock hazards. Be sure to distribute the cables at enough distance
from the lamp housing and power supply unit.
Fig. 1
Fig. 2
³
²@
ƒ
…
|
‡†

7
Fig. 3
Fig. 4
OPERATION
1Voltage Indication (Fig. 3 & 4)
1. Ensure that the brightness control knob @ is set to MIN (lowest voltage)
then set the main switch ² to “ I” (ON). (The POWER LED ³ lights up.)
2. Turn the control knob @ toward MAX (highest voltage) to increase the
voltage intensity and brighten the illumination.
}The position marked indicates the position with which daylight suitable
for photography can be obtained when an LBD filter is engaged in the
light path.
Hand Switch Operation
}When the hand switch is connected (the REMOTE LED | lights), the
brightness control knob @ is defeated but the brightness control knob ƒ
of the hand switch is activated.
1. Press the lamp ON-OFF switch … and adjust the brightness with the con-
trol knob ƒ.
2. To turn the lamp OFF, press the lamp ON-OFF switch … again.
# When the REMOTE LED | is lit, the hand switch in standby mode and
consumes about 2.5 W of power.
When the equipment is not to be used for a long period of time, be sure to
set the main switch ² to “ ” (OFF).
|
²
@