Olympus BX3M-PSLED Manuel utilisateur

INSTRUCTIONS
This instruction manual is for the power supply for LED BX3M-PSLED.
To ensure the safety, obtain optimum performance and to familiarize yourself fully with
the use of this product, we recommend that you study this manual thoroughly before
operating this product, and always keep this manual at hand when operating this product.
Retain this instruction manual in an easily accessible place near the work desk for future
reference.
Power supply for LED
BX3M-PSLED
Optical Microscope Accessory

In accordance with European Directive on Waste Electrical and Electronic Equipment, this symbol indicates that the
product must not be disposed of as unsorted municipal waste, but should be collected separately.
Refer to your local Olympus distributor in EU for return and/or collection systems available in your country.
NOTE: This product has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the product is operated
in a commercial environment. This product generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this product in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
FCC WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the product.
This product is a part of the system product which complies with the CE marking.
Please refer to the instruction manual of your system product for the safety instructions related to the CE marking.
For Korea only
이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 가정용
환경에서 사용하는 경우 전파간섭의 우려가 있습니다.

Introduction...............................................................................................................................................1
Safety precautions..............................................................................................................................2
1 Nomenclature of respective portions...........................................................................7
2 Operation procedures................................................................................................................8
1Turning ON the main switch.........................................................................................................................................................8
2Adjusting the brightness..................................................................................................................................................................8
3 Specifications.....................................................................................................................................9
4 Troubleshooting...............................................................................................................................10
5 Assembly................................................................................................................................................11
6 Proper selection of the power supply cord ...........................................................14
Table of Contents


1
BX3M-PSLED
Contents of instruction manuals
This instruction manual is for power supply for LED BX3M-PSLED. For usage in combination with microscope, refer to the
instruction manual for your microscope.
The power supply for LED BX3M-PSLED is a control box which is used to control LED light source installed on the
microscope.
Introduction

2
If the product is used in a manner not specified by this manual, the safety of the user may be imperiled. In addition, the
product may also be damaged. Always use the product according to this instruction manual.
The following symbols are used in this instruction manual.
CAUTION : Indicates a potentially hazardous situation which, if not avoided, may result in
minor or moderate injury.
NOTE
: Indicates a potentially hazardous situation which, if not avoided, may result in
damage to the product or other property.
TIP
: Indicates the useful knowledge or information for use.
CAUTION - Installation of the product -
Install the product on a sturdy, level table or bench.
If you install the product on an unstable table or a tilted table, the product may drop and you may get injured.
Safety precautions

3
BX3M-PSLED
CAUTION - Electric safety -
Always use the power cord provided by Olympus.
If the proper AC adapter and the power cord is not used, the electric safety and the EMC (Electro-Magnetic
Compatibility) performance of the product cannot be assured.
If no power cord is provided, please select the proper power cord by referring to the section “Proper selection of the
power supply cord” at the end of this instruction manual.
Always connect the ground terminal.
Connect the ground terminal of the power cord and that of the power outlet. If the product is not grounded, our
intended electric safety and EMC performance of the product can not be assured.
Do not use the product in close proximity to the sources of strong electromagnetic radiation.
Proper operation may be interfered. The electromagnetic environment should be evaluated prior to operation of the
product.
Remove the power cord in case of emergency.
In case of emergency, be sure to unplug the power cord from the power cord connector on the product or from the
wall power outlet. Install the product at the location where you can reach the power cord connector or the wall power
outlet at hand to remove the power cord quickly.

4
Do not look directly at the light from the LED light source for a long time.
The LED built in the LED lamp house (separately available) is basically eye-safe. However, do not look directly at the
light from the LED lamp house for a long time, since it may cause damage to your eyes.
If the laws or regulations for workers health and safety have been established, follow them when using the
microscope.
Do not look directly at the light coming out from the objective or the specular reflection light from the
specimen.
Do not look directly at the light coming out from the objective for a long time, since it may cause damage to your
eyes.
Do not expose your skin to the light coming out from the objective for a long time.
If your skin is exposed to the light coming out from the objective for a long time, you may get burned.
CAUTION - Protection of electrick shock -
CAUTION - LED (light emitting diode) -
Keep the power cord and cables sufficiently away from the lamp housing.
If the power cord and cables contact a hot area of the lamp housing, they could melt and cause electric shock.

5
BX3M-PSLED
The following symbols are placed on the product.
Study the meaning of the symbols and always use the product in the safest possible manner.
Symbol Meaning
Indicates a non-specific general hazard. Follow the cautions given after this symbol
or in the instruction manual.
Indicates that the main switch is ON.
Indicates that the main switch is OFF.
When caution labels are dirty or peeled off, contact Olympus for replacement or inquiries.
CAUTION - Safety symbols -

6
Handling precautions
1. Wipe the portions with a dry soft cloth.
If the dirt cannot be removed by dry-wiping, moisten a soft cloth with diluted neutral detergent and wipe the dirty
surface with it.
Do not use the organic solvents because they may deteriorate the coated surface or plastic parts.
2. Before disposing of this product, be sure to follow the regulations and rules of your local government.
NOTE
Maintenance and storage
·This product is a precision instrument. Handle it with care and avoid subjecting it to a sudden or severe
impact.
·Never disassemble any part of the product. Otherwise, failure could be caused.
·Do not use this product in areas where it may be subjected to direct sunlight, high temperature and/or
humidity, dust or vibrations.
(For the conditions of operating environments, see “3 Specifications” on page 9.)
·Before attaching or detaching the LED lamp house (separately available), set the main switch to (OFF).
NOTE
Table des matières
Autres manuels Olympus Alimentation