NOSHOK 800 Series Manuel utilisateur

800 Series
Electronic Indicating
Pressure Transmitter/Switch
Operating Instructions

1. General information

Table Of Contents
Declarations of conformity can be found online at www.noshok.com.
1. General information 4
2. Design and function 5
3. Safety 7
4. Transport, packaging and storage 10
5. Usage, operation 11
6. Faults 21
7. Maintenance and cleaning 24
8. Dismounting, return and disposal 25
9. Specications 27
10.
Accessories and spare parts
34

1. General information
4
The pressure transmitter/switch described in these operating instructions has been designed and
manufactured using state-of-the-art technology. All components are subject to stringent quality and
ISO 9001:2015.
These operating instructions contain important information on handling the instrument. Working
safely requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the
instrument’s range of use.
The operating instructions are part of the product and must be kept in the immediate vicinity of the
instrument and readily accessible to skilled personnel at any time.
Skilled personnel must have carefully read and understood the operating instructions prior to
beginning any work.
The manufacturer’s liability is void in the case of any damage caused by using the product contrary
The general terms and conditions contained in the sales documentation shall apply.
Further information:
www.noshok.com
T: 440.243.0888
F: 440.243.3472

2. Design and function
5
2.1 Scope of delivery
Pressure transmitter/switch
Operating instructions
Test report
Cross-check scope of delivery with delivery note.
2.2 Overview
1INFO button
2Digital indicator
3Status display, switching outputs
4MENU button
5Confirmation button
6Electrical connection
Process connection, spanner flats
8Process connection, thread

6
4-digit LED display
Display of pressure value
Display of menu item
Display of parameter
Status of switching output 1
Status of switching output 2 (optional)
Display mode
▶Short press
Display of unit
▶Long press
Display of the set parameters, see
chapter 5.7 “Parameters”
Programming mode
▶Short press
Menu up
Parameter value up (step-wise)
▶Long press
Menu up
Parameter value up (fast)
Display mode
Short press
Display of unit
Long press
Jumping into the programming mode
Programming mode
Short press
Menu down
Parameter value down (step-wise)
Long press
Menu down
Parameter value down (fast)
Display mode
Short press
Display of unit
Programming mode
Short press
Selection of menu item
2.1 Display and operating unit
2. Design and function

7
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to property or
the environment, if not avoided.
WARNING!
... indicates a potentially dangerous situation that can result in burns caused by hot surfaces or liquids,
if not avoided.
Information
3.2 Intended use
The instrument has been designed and built solely for the intended use described here, and may only be used
accordingly.The manufacturer shall not be liable for claims of any type based on operation contrary to the intended
use.
Intended use
The 800 Series Pressure Transmitter/Switch is used for the switching of circuits as a function of the measured
The switching conditions can be programmed directly at the pressure transmitter/switch (switch and reset points,etc.).
This is a class B instrument for emissions and is intended for use in industrial environments. In other environments,
e.g. residential or commercial installations, it can intefere with other equipment under certain conditions. In such
circumstances the operator is expected to take the appropriate measures.

8
Application areas
Only use the pressure transmitter/switch in applications that lie within its technical performance limits (e.g. max.
ambient temperature, material compatibility, etc.).
Technical restrictions
The overload pressure must never be exceeded, even when failures occur in the end-use application. Loadings
above the overload safety can cause measuring errors.
Pressure surges below the nominal pressure and shorter than 1 ms can cause measuring errors.
For applications where pressure spikes can occur, the use of a restrictor is recommended. The restrictor narrows
the pressure port to 0.3 mm and thus increases the resistance against pressure spikes.
With a high ambient temperature and a high UV irradiation, the pressure transmitter/switch must be installed with
additional covering in order to avoid damage to the digital indicator and buttons.
The medium temperature at the instrument must not exceed 185 °F (85 °C). With hotter media, a cooling element
can provide a solution (see chapter 10 “Accessories and spare parts”).
3.3 Personnel qualication
Skilled personnel
regulations, current standards and directives, are capable of carrying out the work described and independently
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
3. Safety

9
3. Safety
3.4 Use of accessories and spare parts
It is recommended to use original accessories and original spare parts from NOSHOK. Using accessories and spare
parts from third parties can lead to damage to the instrument or accidents, due to quality defects or other reasons.
NOSHOK assumes no liability for damage or accidents caused by a malfunction or unsuitability of accessories and
spare parts which do not originate from NOSHOK (e.g. non-compliance with the IP ingress protection of connectors).
No warranty claims can be made which arise due to a malfunction or unsuitability of any accessory or spare part from
a third party.
3.5 Labeling, safety marks
Product label
If the serial number becomes illegible (e.g. due to mechanical damage or overpainting), traceability will no longer be
possible.
S# Serial no.
P# Product no. Approvals
Measuring range Coded date of manufacture
IO-Link version (option)
Symbols
Before mounting and commissioning the instrument, ensure you read the operating instructions!
www.noshok.com
800 Series

10
4. Transport, packaging and storage
In order to avoid damage at the diaphragm and/or the process connection thread, remove the
protection cap by hand only just before installation.
Keep the protection cap for subsequent storage or transport.
Fit the protection cap before dismounting and transporting the instrument.
4.1 Transport
additionally check the diaphragm for any optical damage. Obvious damage must be reported immediately.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending
for repair).
Permissible conditions at the place of storage:
Storage temperature: -4 °F - 158 °F (-20 °C - 70 °C)
Humidity: 45 - 75 % relative humidity (no condensation)
In order to protect the diaphragm, mount the protection cap before storing the instrument.