NKE TL25 Manuel utilisateur

nke
– marine electronics
Z.I. Kerandré – Rue Gutenberg – 56700 HENNEBONT- FRANCE
http://www.nke.fr – After sale service n°0 892 680 656.
Multifunction
TL25
and its remote control
Product reference : 90-60-244 white / 90-60-256 black
USER GUIDE
and
INSTALLATION GUIDE
REV : 1

- 2 –
TL25 User guide–- 33-60-021-000
TABLE OF CONTENT
1 USING...................................................................................................................................3
1.1 P
RESENTATION
.....................................................................................................................3
1.2 L
IST OF CHANNELS CREATED
.................................................................................................5
1.3 K
EYPAD FUNCTIONS OF THE REMOTE CONTROL
.......................................................................6
1.4 C
HANNEL SELECTION
............................................................................................................6
1.5 W
HAT IS A SUB
-
CHANNEL
......................................................................................................7
1.6 A
LARMES SETTING
................................................................................................................8
1.7 F
ILTERING OF THE CHANNELS
...............................................................................................10
1.8 L
IGHTING SETTING
..............................................................................................................11
1.9
U
NITS
.................................................................................................................................12
1.10 Z
ERO SETTING OF THE DAILY LOG
......................................................................................13
1.11 C
HOICE OF LANGUAGES
...................................................................................................14
1.12 U
SE OF THE CHRONOMETER
.............................................................................................15
1.13 NMEA
LINK
....................................................................................................................16
1.14 T
ECHNICAL SPECIFICATIONS
.............................................................................................18
1.15 V
ERSION AND ADDRESS NUMBER OF THE DISPLAY
..............................................................18
1.16 D
IAGNOSTIC FOR
1
ST
LEVEL TROUBLESHOOTING
.................................................................18
1.17 TL25
INITIALISATION
:
SEE CHAPTER
4.8............................................................................18
2 SENSOR CALIBRATION....................................................................................................19
2.1 S
ETTING PROCEDURE
OF THE CALIBRATION COEFFICIENT
:......................................................19
2.2 O
FFSET SETTING PROCEDURE
.............................................................................................19
2.3 A
UTOCOMPENSATION OF THE FLUXGATE COMPASS
................................................................20
3 INSTALLATION ..................................................................................................................21
3.1 P
ACKING LIST
:...................................................................................................................21
3.2 L
IST OF ACCESSORIES
.........................................................................................................21
3.3 I
NSTALLATION PRECAUTIONS
................................................................................................21
3.4 M
OUNTING ON MAST FOOT SUPPORT
....................................................................................22
3.5 W
ALL MOUNTING
................................................................................................................23
3.6 C
ONNECTION TO THE
T
OPLINE BUS AND TO THE
NMEA
BUS OF THE INSTALLATION
...................24
3.7 I
DENTIFICATION OF THE CABLE WIRES
...................................................................................24
3.8 TL25
AND REMOTE CONTROL INITIALIZATION
.........................................................................25

- 3 –
TL25 User guide–- 33-60-021-000
1 USING
1.1 Presentation
The
Multifunction TL25 is a display from the TOPLINE range. Its three screens, with high
definition LCD technology, offer excellent readability and a wide angle of view of the data
displayed, whether by daylight or at night. It is connected to the TOPLINE bus of your
installation and displays all the channels available on the bus.
The TL25 is controlled using either a cable remote control or a radio remote control (not
included with the product).
Chanel name
Data value
Unit
Alarm signal

- 4 –
TL25 User guide–- 33-60-021-000
Architecture of the installation
The presence of the equipment in the following diagram is for information only, and does not
represent the equipment of your installation.
Cable TOPLINE
20-61-001
GND
DATA black
12VDC white
Figure 1
log depth interface
90-60-450
log
speedomètre depth
connecting box
90-60-417
NMEA -
NMEA +
input NMEA
nke
TL 25
16.85
BOAT SPEED
APP WIND A
105-
KNOTS
DEGRES
10.50
DEPTH
METERS

- 5 –
TL25 User guide–- 33-60-021-000
1.2 List of channels created
The master display, whether it is the TL25 or any other TOPLINE display, and each TOPLINE
sensor, automatically create their respective channels when they are connected to the
TOPLINE bus.
Channels created
by the
TL25
when set as
master display
Channel designation
Magnetic heading
Apparent wind angle
Apparent wind speed
Depth
Boat speed
Maximum and average speed
Distance and bearing to man over
board
Configuration
Bus voltage
VMG
CMG
True wind speed
True wind angle
True wind direction
Corrected heading
Estimated distance
Estimated angle
Total log
Tip log
NMEA Performance
channels displayed
Target speed
Heading on other side
Optimum wind angle
NMEA channels
displayed
Optimum VMG angle
Optimum CMG angle
Efficiency at close-haul
Polar efficiency
Speed over Ground and Course over
ground
Cross-track error
Please note that the channels MAX SPD and AVERAGE SPD can be accessed when the TL25 is
master. In this case, these channels are displayed alternatively on one single screen. By default, this
channel is calculated using the surface speed, and in the absence of the latter it will be calculated using
the bottom speed. These average and maximum values are calculated from the last power-up of your
installation. You can reset these channels to zero, without switching off the bus : select the channel
MAX SPD and AVERAGE SPD then press the key for 2 seconds.

- 6 –
TL25 User guide–- 33-60-021-000
1.3 Keypad functions of the remote control
-key
Press this key to select one of the three display screens of the TL25. The selected screen
flickers.
-Low key and High key
These keys allow to select a different channel to the one already displayed. They also allow to
increment or decrement a data which is in the process of being modified.
-key
The remote control also enables you to control the other displays of your TOPLINE installation,
the address of which is lower than the address of the remote control. Press this key to select
the TOPLINE display, which you wish to operate.
-
Ent
key
This key allows to access the sub-channels and to validate the settings you implement. Brief
pressure on this key also allows to set the level of lighting.
-
Mob
Man Over Board key
Press this key for 5 seconds, and the function «Man Over Board» is activated. When a
speedometer and a compass are connected to the TOPLINE bus, the displays then
automatically indicate the estimated heading and distance to reach the man over board. If your
installation only comprises a speedometer, then only the estimated distance will be displayed.
To disable the «Man Over Board» alarm, you must cut off the power supply of your TOPLINE
installation.
CAUTION : the calculation of the estimate, for the Man Over Board function, does not take into
account the drift of the boat caused by the current and the wind.
For more detailed information, please refer to the remote control user guide.
1.4 Channel selection
The three screens of the TL25 are independent. Using the remote control, configure the display
according to your requirements. Examples of configuration:
nke
TL 25
16.85
BOAT SPEED
APP WIND A
105-
KNOTS
DEGREES
10.50
DEPTH
METRES
nke
TL 25
16.85
BOAT SPEED
APP WIND A
105
274°
COMPAS HEAD
NOEUDS
DEGREES
DEGREES

- 7 –
TL25 User guide–- 33-60-021-000
1.4.1 Procedure
1.4.2 List of channels displayed
The master display, whether it is the TL25 or any other TOPLINE display, and each TOPLINE
sensor, automatically create their respective channels when they are connected to the
TOPLINE bus. You will find the list of created channels in annex 1.
1.5 What is a sub-channel
The sub-channels are made to modify setting and display parameters of the channels. For
example, the sub-channels of the surface speed channel are:
-offset and calibration coefficient : setting parameters of the log-speedometer sensor,
-the measurement unit : in knots or in km/hr,
-filter setting,
-high alarm and low alarm setting.
The same applies to all channels present on the TOPLINE bus. The following chapters provide
detailed explanations on how to access the sub-channels and implement the settings.
CAUTION : if your installation is equipped with several TOPLINE displays, make sure that
the remote control controls the display which you wish to operate. Press the key
repeatedly, until the intended display blinks.
1
Using the key
from wich you wish to change the channel.
2
nke
TL 25
16.85
BOAT SPEED
APP WIND A
105
274°
COMPAS HEAD
NOEUDS
DEGREES
DEGREES
, select the row
Figure 2
TL 25
DEPTH
The new display is save in memory
select in the list,
50.20
METRES
the channel you wish to display.
The selected row flikers.
Using the key

- 8 –
TL25 User guide–- 33-60-021-000
1.6 Alarms setting
The setting of an alarm enables you to monitor the value of a channel. When the preset
threshold is exceeded, a warning message is displayed and an audible alarm is activated. For
example, you can set an upper threshold and a lower threshold on the surface speed channel.
High alarm is activated when the display is higher than the programmed threshold.
Low alarm is activated when the display is lower than the programmed threshold.
To cancel the alarm of a channel, enter the value 0in the upper alarm and the lower alarm.
Thus, the setting of the alarms will allow you to supervise your TOPLINE installation effectively
as well as the good operation of your boat.
Note that for angular channels such as magnetic heading or wind angle, the sub-channels of
alarms are the alarm base and the alarm range.
1.6.1 Setting procedure
CAUTION : if your installation is equipped with several TOPLINE displays, make sure that
the remote control controls the display which you wish to operate. Press the key
repeatedly, until the intended display flickers.
Ent
Ent
1
2
Press and hold the key
until the sub-channel
ALARM
appears. Release the key.
4
to select the sub-channel
LOW ALARM
ou
HIGH ALARM
TL 25
16.85
BOAT SPEED
KNOTS
HIGH ALARM
Figure 3
0
Then successively press the key
TL 25
HIGH ALARM
5
The new value is saved in memory
Validate and exite the alarm menu by maintaining pressure on
Ent
TL 25
LOW ALARME
20
Using the keys set the new alarm value "
20"
0.25
3
Using the key , select the channel
The selected row flikers.
from wich you wish to set an alarm.
nke
TL 25
16.85
BOAT SPEED
APP WIND A
105-
KNOTS
DEGRES
10.50
DEPTH
METRES

- 9 –
TL25 User guide–- 33-60-021-000
1.6.2 Alarms activation procedure
After having set the alarms, you can activate or disable all the alarms. When alarms are
activated, the alarm symbol below appears at the bottom left of the display :
Ent
1
Using the keys
select the channel
CONFIG
2
Press and hold the key
3
nke
TL 25
16.85
BOAT SPEED
APP WIND A
105-
274°
COMP HEAD
KNOTS
DEGREES
DEGREES
VALID ALARME
Figure 4
TL 25
CONFIG
Ent
Using the keys
until the sub-channel
valid alarme
appears. Release.
select
YES
Validate by maintaining pressure on the key
NO
YES
After 5 s, the TL25 automatically exits the setting mode

- 10 –
TL25 User guide–- 33-60-021-000
1.7 Filtering of the channels
The level of filtering of a channel determines the frequency of update of the data displayed.
For example, in rough sea when the boat moves significantly, it is useful to increase the filtering
of the speed channel to stabilise the value displayed. Conversely, in calm sea, low filtering will
be preferable to obtain a fast response of the display.
Filtering is adjustable between 1and 32, and the default value is 8. The lower this value is, the
higher the frequency of update is.
Filter setting procedure
Ent
Ent
1
Using the key
select the channel you need to change the filtering.
2
Presse and hold the key
until
high
ALARM
appears. Release.
3
4
to select the sub-channel
FILTERING
TL 25
16.85
BOAT SPEED
TL 25
FILTERING
Figure 5
8
Then successively press the key
TL 25
HIGH ALARM
5
The new filtering value is saved in memory
Validate and exits the menu by maintaining a pressure un key
Ent
TL 25
FILTERING
10
Using the key set the new filtering value
10
0.25
The selected channel flickers
nke
TL 25
16.85
BOAT SPEED
APP WIND A
105-
274°
COMP HEAD
KNOTS
DEGREES
DEGREES
Table des matières