Ninglu AM706 Manuel utilisateur

Anemometer AM706
Operation & Installation Manual
Document: NLT-AM706C-SSEN
Edition: V170701(EXP)
Software: V1.3

Contents
System description ............................................................. 4
Main unit ....................................................................... 4
Sensor unit .................................................................... 4
Alarm unit ...................................................................... 5
Peripheral equipment ....................................................... 5
Printer ..................................................................... 6
Repeater .................................................................. 6
System specification ........................................................... 7
Physical ........................................................................ 7
Power ........................................................................... 8
Measurment ................................................................... 8
Functions ...................................................................... 8
Interface ........................................................................ 8
Operation .......................................................................... 9
Sleep mode .................................................................... 9
Backlight ....................................................................... 9
Unit of the wind speed ...................................................... 9
Power drops alarm........................................................... 9
Wind speed alarm level ................................................... 10
Set the wind alarm “dividing value” ................................... 10
Set the first level alarm value ........................................... 10
Set the second level alarm value ....................................... 11
Alarm .......................................................................... 12
Mute the alarm .............................................................. 12
Turn off the alarm .......................................................... 12
Gust mode ................................................................... 12
Printed time interval ....................................................... 13
Printer setting ............................................................... 14
Printed Format .............................................................. 15
The display of the second line LEDs .................................. 16
Calibration ...................................................................... 17

Installation ...................................................................... 18
Main unit ..................................................................... 18
Table mounting ....................................................... 18
Flush mounting ....................................................... 19
Sensor unit .................................................................. 20
Alarm unit (AM706A1) ..................................................... 22
Installation diagram Wiring diagram ....... 22
Alarm unit (AM706A2) ..................................................... 23
Installation diagram .................................................. 23
Wiring diagram ........................................................ 23
System diagrams .............................................................. 24
Wiring diagram ................................................................. 25
Supplementary wiring for printer DPU-414 .......................... 26
Supplementary wiring for repeater IR761 ............................ 26

4
AM706C
AM706S
System description
Anemometer AM706 is a combined instrument for relative wind speed
(accuracy ±5%) and relative wind direction (display accuracy 10 °, output
accuracy ± 1 °). With inputting GPS (RMC) data, users can print out latitude
and longitude information together with wind speed and direction.
CCR alarm and deck alarm automatically give warnings when wind speed
exceeds the setting value.
The AM706 is consisted of 3 parts: Main unit, Sensor unit, Alarm units.
Main unit
The main unit AM706C receives the signal from
the sensor unit, and displays:
Relative wind direction
Relative wind speed
Maximum wind speed
First and second level alarm settings
The main unit also output the setting of the wind speed
alarm to the alarm unit.
Sensor unit
The Sensor unit AM706S includes three parts:
Wind speed sensor: a rotor with three wind cups.
Wind direction sensor:
a wind vane to drive an absolute angle sensor unit.
Junction box
It has a waterproof junction box and a sensor unit transmitter.

5
AM706A1
System description
Alarm unit
AM706A1 is installed in the CCR (cargo control room).
Light source: LEDs
Light form: flash
Light color: red
Sound source: buzzer
Sound form: continues
Sound decibel: 60dB~85dB(A)
AM706A2 is installed on the cargo deck
Light source: Super bright LEDs
Light form: rotating flash
Light color: red
Sound source: horn
Sound form: continues
Sound decibel: 110dB (A)
Peripheral equipment
Printer: DPU414, print date, wind speed & direction and so on
Repeater: IR761, redisplay the wind speed & direction
VDR: (vessel data recorder): record data from the main unit
GPS: input position signal to the main unit.
AM706A2

6
DPU414
IR761
System description
Printer
Operating temperature: 0 ~ 40℃
Humidity: 30 ~ 80% RH
Weight: 580 g
Power: AC220/110V with adaptor
Current: 2A (Max)
Lifetime: 500 thousand bite
Printed mode: thermal serial dot-matrix
Thermal record paper: CX-050B a roll of paper =30m 10 rolls/group
Interface: 8 bite parallel /RS-232C serial
Printed paper/content width: 112 mm/89.6 mm
Repeater
Operating temperature: 0 ~ 40℃
Humidity: 10 ~ 90% RH
Weight: 1.4kg
Protection: IP 23
Power: DC24V
Consumption: 2W (24V)
Compass safe distance: 85 cm

7
System specification
Physical
Operating temperature:
Main unit -15°C~+55°C
Sensor unit -15°C~+70°C
Alarm unit -15°C~+55°C
Storage temperature:
Main unit -20°C~+70°C
Sensor unit -20°C~+85°C
Alarm unit -20°C~+70°C
Humidity:
Main unit 10%-90% relative humidity
Sensor unit 10%-100% relative humidity
Alarm unit 10%-100% relative humidity
IP degree
Main unit IP 22
Sensor unit: IP 56
Alarm unit: AM706A1: IP 54
AM706A2: IP 56
Weight:
Main unit 2kg
Sensor unit 10 kg
Alarm unit: AM706A1: 0.3kg
AM706A2: 3kg

8
System specification
Power
Main display power supply: DC24V (20-32V)
Wind sensor working power: DC9V to DC36V
Power consumption: less than 10W (DC24V)
AC adaptor: AC110/220V to DC24V
Measurment
The range of the wind speed: 1.2~25m/s
The range of the wind direction: 0~359°
The accuracy of the relative wind speed: ± 5% (min: 0.1m/s)
The accuracy of the relative wind direction: display accuracy 10 °,
output accuracy ± 1 °
Min start wind speed: ≤1.2m/s
Functions
Alarm: power drops alarm, wind speed alarm
Calibration: wind direction can be calibrated
Interface
Wind sensor input: NMEA0183-MWV
Output to alarm unit: Switching value
Output to repeater IR761: NMEA0183-MWV
Output to printer DPU414: RS232C
GPS input: NMEA0183-RMC
Direction and speed output: 4800bps

9
Operation
Sleep mode
Press [▲] and [▼] at the same time, turn the main unit into sleep mode.
Backlight
Press [▲] or [▼] to set backlight of the main unit.
Unit of the wind speed
Press [S] on the main unit to inter the “wind speed unit selection”, then
press [▲] or [▼] to select the speed unit. You can choose “m/s, km/h,
kts”.
Power drops alarm
The main unit will sound an alarm when one of the power supplies drops off.
Press any key on the main unit to mute the alarm.

10
Operation
Wind speed alarm level
There are two levels alarm. If the wind speed achieves or exceeds the first
level setting, the first level alarm is triggered with 1st form of sound/light.
If the wind speed achieves or exceeds the second level setting, the second
level alarm is triggered with 2nd form of sound/light.
Set the wind alarm “dividing value”
Press [F] once on the main unit to enter the “wind alarm dividing value
setting”. “dId” is flashing. The first line LEDs show “dId”, then press [▲] or
[▼] to set the dividing value. The second line LEDs show the setting value.
The dividing value here after will be referred to as “X”.
Set the first level alarm value
Press [F] twice on the main unit to enter the “1st level alarm setting”. “AL1”
is flashing. The first line LEDs show “AL1”, then press [▲] or [▼] to set the
value of the 1st level alarm. The second line LEDs show the setting value.
Autres manuels pour AM706
2
Table des matières
Autres manuels Ninglu Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur