Nigos DVD-240 Manuel utilisateur


1
TABLE OF CONTENTS
1.
2.
3.
4.
5.
5.1
5.2
6.
6.1
6.2
6.3 HOLD
7. MAINTENANCE
8.
8.1 :
QUICK REFERENCE GUIDE
TECHNICAL SPECIFICATION
DESCRIPTION OF MOISTURE METER
TURNING METER ON / OFF AND AUTOCALIBRATION PROCEDURE
DEVICE SET-UP AND ADJUSTMENT FOR MEASUREMENT
9.1 Air temperature and relative humidity measurement procedure
WOOD DENSITY (TYPE) parameter setting
WOOD THICKNESS parameter setting
WOOD MOISTURE CONTENT MEASUREMENT
Timber MC measurement procedure
Veneer MC measurement procedure
function
AND BATTERY REPLACEMENT
APPENDIX
Appendix 1 Additional information regarding wood density and wood moisture content
8.2 Appendix 2: Wood density table
9. AIR TEMPERATURE AND RELATIVE HUMIDITY MEASUREMENT (OPTIONAL)
................................................................................................................... 2
................................................................................................................. 5
...................................................................................................... 6
.......................................................... 8
........................................................................ 10
................................................................................ 10
...................................................................................... 12
....................................................................................... 14
..................................................................................... 16
..................................................................................... 17
........................................................................................................................ 18
............................................................................................ 19
.......................................................................................................................................... 20
.... 20
............................................................................................. 21
................................................ 24
............................................ 25
DVD-240

DVD-240
2
1. Turning the meter ON
- Press the button briefly (back side untouched)
- Wait for autocalibration process to end and()
kal
to be displayed
0)0
1. QUICK REFERENCE GUIDE
0ff
HOLD
ON
OFF
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
kal
ON
OFF
ON
OFF
2. Wood density adjustment
- Press and hold button
to adjust timber density (given in t/ )m
3
t
m
3
; use and
)64
HOLD
ON
OFF
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
)64
t
m
3

DVD-240
3
3. Wood thickness adjustment 4. Measurement - moisture content reading
- Gently press the back side of the meter on the flat
and smooth surface of wood sample "along fibers"
- Read the measured value on display (in %MC)
- Repeat the measurement in several points
- Press and hold button ; use and
to adjust wood thickness (given in mm)
mm
2#0
HOLD
ON
OFF
UP/DOWN
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
2#0
mm
)64
HOLD
ON
OFF
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
1%1
HOLD

DVD-240
4
5. Measurement - option HOLD
-
If needed, press briefly button to hold the
measured value displayed for later reading
- Press same button again to continue measuring
-
Press the button briefly
0ff
HOLD
HOLD
ON
OFF
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
0ff
ON
OFF
ON
OFF
6. Turning the meter OFF
HOLD
)64
HOLD
ON
OFF
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
&1
HOLD

DVD-240
2$0
HOLD
ON
OFF
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
DVD-240
5
2. TECHNICAL SPECIFICATION
GENERAL CHARACTERISTICS
Power supply
Operating conditions
Storage
Device dimensions W H
Sensor dimensions (W x H)
Weight
Display
(xxD)
9 V battery, Alkaline or NiCd Aku.
LCD, digital
80 x 140 x 40 (mm)
(mm)
T:550C;RH:590%
0
¸¸
¸¸T:-40 85 C;RH:5 90%
()
(42 x 78)
210 g
0
MEASUREMENT
Measurement resolution
Wood MC measurement range
Wood thickness range
Wood density range
0.1 %
(0.5 40) (mm)
(
(0 100) (%)
0.30 1.10) (t/m )
¸
¸
¸
3

OPEN
DVD-240
2$0
HOLD
ON
OFF
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
3. DESCRIPTION OF MOISTURE METER
1
4
5
68
7
6
DVD-240
2
3

7
Wood moisture content meter is made for
quick reading of wood moisture by simple pressing
on flat wooden surface.
There is a specially designed sensor plate on the
back side of the meter which measures wood MC
when pressed on the wood surface.
In order to achieve accurate measuring data using
this meter it is required to perform certain procedures
before measurement such as autocalibration and
basic parameter adjustments. Following chapters of
this manual will contain more information th
procedures.
DVD-240
Device is placed in the plastic case with large display
for indication of all measurement data and flat
keyboard for device control.
about ese
DVD-240 FRONT SIDE LAYOUT
LCD DISPLAY
WOOD THICKNESS
UP DOWN
WOOD DENSITY
ON / OFF
HOLD
DVD-240 BACK SIDE LAYOUT
SENSOR PLATE
1. displays:
- Measured moisture content
- Parameter values during set-up
- State and error massages
2. button
3. Buttons and used for increase or
decrease of value of selected parameter
4. button
5. Power button
6. button
7. measures moisture content when
pressed against smooth wood surface
8. Battery compartment
DVD-240

ON
OFF
8
4. TURNING METER ON / OFF AND AUTOCALIBRATION PROCEDURE
Turning the meter ON
It is essentially important to ensure that meter during autocalibration has
such position that sensor plate hangs free in the air, i.e. there is nothing
behind sensor plate blocking it! Do not hold fingers or other objects behind
sensor plate during autocalibration. Existence of any object near sensor
plate during autocalibration procedure can corrupt this process and result
in inaccurate measurement and measuring errors.
is performed with brief pressing on the button . Meter will perform certain additional
functions immediately after powering on. When the button is pressed, message
After a few seconds, when autocalibration procedure is finished, meter will
display: ,
kal
0)0
is displayed for few seconds.
During this time, meter is performing procedure, i.e. series of test-measurements
required for its adaptation to current operating conditions (ambient temperature, air humidity, etc).
which signals that it is ready for measurement or other adjustments.
Autocalibration procedure is performed each time the meter is powered ON,
which ensures reliability of measurement in all declared conditions.
DVD-240 AUTOCALIBRATION
0ff
HOLD
ON
OFF
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
kal
ON
OFF
DVD-240

9
ON
OFF
Turning meter OFF is performed with short pressing on the button .
Display will shortly display message
.
0ff
after which it will turn off.
When it is turned off, the meter does not consume energy from the
battery
If there is any doubt in measuring accuracy and possible error in autocalibration as a cause of false
measurement, autocalibration should be repeated by simple turning off and turning on the meter again.
Meter can detect large calibration errors itself. In this situation, after removing all objects away from back side
of the meter (so it "measures air"), message is displayed.
Ler
0ff
HOLD
ON
OFF
UP/DOWN
UP/DOWN
mm
t
m
3
WOOD MOISTURE METER
0ff
ON
OFF
DVD-240
Table des matières
Autres manuels Nigos Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur