Niagara SmartPD Manuel utilisateur

SmartPD Meter
Installation & Operation Manual
®
IOM
M30218 Rev. A


SmartPD Meter
Installation & Operation Manual
CONTENTS
®
I. HANDLING & STORAGE ......................................................................................................................... 1
Inspection and Handling
Disposal and Recycling
Storage
II. GENERAL SAFETY.................................................................................................................................. 2
Authorized Personnel
Use
Misuse
III. PRODUCT DESCRIPTION ...................................................................................................................... 3
Function
Applications
Features
TechnicalSpecications
Approvals
Temperature and Accuracy Charts
Figure 1. SND Ambient vs Process Temperature Limit
Figure 2. SOP Ambient vs Process Temperature
Figure 3. Typical Accuracy Curve (Water Calibration)
Pressure Drop Charts
Figure 4. Model SND Line Size B - 0.75” Bore
Figure 5. Model SND Line Size C - 1.00” Bore
Figure 6. Model SND Line Size D - 1.25” Bore
Figure 7. Model SND Line Size F - 1.50” Bore
Figure 8. Model SND Line Size G - 2.00” Bore
Figure 9. Model SOP Line Size C - 1.00” Bore
Figure 10. Model SOP Line Size G - 2.00” Bore
IV. MECHANICAL INSTALLATION.............................................................................................................. 10
Mounting Considerations
Nutating Disc and Oscillating Piston Installation
Figure11.TypicalComponentConguration
Remote Enclosure Installation
Figure 12. Remote Enclosure
V. ELECTRICAL INSTALLATION ............................................................................................................... 12
Integral Transmitter
Figure 13. Integral Transmitter Wiring
Figure 14. Maximum Load Resistance
Remote Transmitter
Figure 15. SmartPD Remote Wiring Diagram

HART Communication
Figure 16. HART Wiring
VI. SET-UP ............................................................................................................................................ 15
Transmitter
Display Description
Resetting Total Mode
Accessing Simulate Mode
Accessing Program Mode
Program Mode Information
Flow Type
Rate Unit
Total Unit
Range Set
Custom Scale
Set Cal
Decimal
Special
Direction
VII. MAINTENANCE ..................................................................................................................................... 20
Preventative Maintenance
VIII. TROUBLESHOOTING........................................................................................................................... 21
IX. DIMENSIONAL DRAWINGS.................................................................................................................. 23
SAFETY SYMBOLS
WARNING:
IDENTIFIES CONDITIONS OR PROCEDURES, WHICH IF NOT
FOLLOWED, COULD RESULT IN SERIOUS INJURY. RISK OF
ELECTRICAL SHOCK.
CAUTION:
IDENTIFIES CONDITIONS OR PROCEDURES, WHICH IF NOT
FOLLOWED, COULD RESULT IN SERIOUS DAMAGE OR FAILURE OF
THE EQUIPMENT.

1
www.niagarameters.com
®
M30218 Rev. A
SmartPD Meter
I. HANDLING AND STORAGE
SAVE THESE INSTRUCTIONS
INSPECTION AND HANDLING
Do not dispose of the carton or packing materials.
Each package should be inspected upon receipt for damage that may have occurred due to mishandling during
shipping. If the unit is received damaged, notify the carrier or the factory for instructions. Failure to do so may
void your warranty. If you have any problems or questions, consult Customer Support at 800-778-9251.
DISPOSAL AND RECYCLING
This product can be recycled by specialized companies and must not be disposed of in a municipal collection
site. If you do not have the means to dispose of properly, please contact Customer Support for return and
disposal instructions or options.
STORAGE
If the device is not scheduled for immediate installation following delivery, the following steps should be
observed:
1. Following inspection, repackage the unit into its original packaging.
2. Select a clean dry site, free of vibration, shock and impact hazards.
3. If storage will be extended longer than 30 days, the unit must be stored at temperatures between
32º and 158º F (0º to 70° C) in non-condensing atmosphere with humidity less than 85%.
CAUTION: DO NOT STORE A NON-POWERED UNIT OUTDOORS FOR A PROLONGED PERIOD.

2
www.niagarameters.com
®
M30218 Rev. A
II. GENERAL SAFETY
AUTHORIZED PERSONNEL
Allinstructionsdescribedinthedocumentmustbeperformedbyauthorizedandqualiedservicepersonnel
only. Before installing the unit, please read these instructions and familiarize yourself with the requirements and
functions of the device. The required personal protective equipment must always be worn when servicing this
device.
USE
The device is solely intended for use as described in this manual. Reliable operation is ensured only if the
instrumentisusedaccordingtothespecicationsdescribedinthisdocument.Forsafetyandwarranty
reasons,useofaccessoryequipmentnotrecommendedbythemanufacturerandanymodicationofthis
deviceisexplicitlyforbidden.Allservicingofthisequipmentmustbeperformedbyqualiedservicepersonnel
only. This device should be mounted in locations where it will not be subject to tampering by unauthorized
personnel.
MISUSE
Improper use or installation of this device may cause the following:
• Personalinjuryorharm
• Applicationspecichazardssuchasvesseloverll
• Damagetothedeviceorsystem
If any questions or problems arise during installation of this equipment, please contact Customer Support at
800-778-9251.

3
www.niagarameters.com
®
M30218 Rev. A
III. PRODUCT DESCRIPTION
FUNCTION
TheSmartPDisavolumetricmeterthatprovidestotalvolumeandowratemeasurementsbywayofan
electronic transmitter. This 2-wire device provides an analog response by way of a 4-20 mA signal, digital
feedback via HART communication, and a visual indication of change on an LCD. There are two variations of this
meter; the SmartPD nutating disc (SND), and the SmartPD oscillating piston (SOP).
TheSmartPDmeteriscapableofmeasuringvolumeandowrateforawiderangeofmaterialsinanumberof
different industries. It is a compact, space saving design that eliminates the need for upstream and downstream
piperequirements.Itisofferedinawiderangeofmaterials,nishesandlinesizes.
APPLICATIONS
• ChemicalProcessing
• Industrialmanufacturing
• Paint
• Pulpandpaper
• FoodProcessing
• ConcreteBatching
• Cosmetic
• Pharmaceutical
• Agricultural
• Automotive
FEATURES
• 2wirelooppowered
• 4-20mAproportionaltoow
• HARTCommunication
• 2linedigitalLCDdisplay
• Remotedistanceupto50’(15m)
• Providestotalandowrates
• Wideprocesstemperaturerating

4
www.niagarameters.com
®
M30218 Rev. A
TECHNICAL SPECIFICATIONS
FUNCTIONAL
Fluid Types Liquids
Temperature See Temperature Graphs
PERFORMANCE
Accuracy SND Models: ± 1.5%
SOP Models: ± 0.5%
Totalizer Repeatability < 0.25%
Flow Rate Repeatability 0.25%
Typical Update Rate of Display 1 Second
Typical Update Rate of 4-20 mA Output 100 mS, 8 mA/second max
PHYSICAL
Flow Direction Unidirectional
Housing/Flanges 1.0 to 2.5”, NPT and Flanges
Pipe Requirements Typical Straight
Process Connections Model Dependent NPT or Flange
Electrical Connections 3/4” NPT
Supply Voltage 24 VDC ± 10%
Line Size Nutating Disc (SND Models): 0.75, 1.0, 1.25, 1.5, 2.0”
Oscillating Piston (SOP Models): 1.0 and 2.0”
Mounting Position Horizontal
Typical Straight Pipe Requirements None
APPROVALS
CE
TEMPERATURE AND ACCURACY CHARTS
Figure 1. SND Ambient vs Process Temperature Limit

5
www.niagarameters.com
®
M30218 Rev. A
Figure 2. SOP Ambient vs Process Temperature
SOP Typical Accuracy Curve
(Water Calibration)
Notes: 1. Meter accuracy validated at 0%, 50% and 100%
owrates.
2. Repeatability of system is measured at 0.25%.
Figure 3. SND Typical Accuracy Curve
(Water Calibration)
Notes: 1.Meteraccuracyvalidatedat0%,10%and50%owrates.
2. Repeatability of system is measured at 0.5%.
FAMILY OIL CALIBRATION
(gpm)
WATER CALIBRATION
(gpm)
SND Line Size B 1-20 2-20
SND Line Size C 2-30 3-30
SND Line Size D 3-50 5-50
SND Line Size F 5-100 8-100
SND Line Size G 8-120 8-100
SOP Line Size C 7-70 7-70
SOP Line Size G 15-150 15-150
Notes: 1.Actualowrangesvaryfordifferentprocessmaterials.
Contact the manufacturer for instructions on selecting an appropriate meter for your application

6
www.niagarameters.com
®
M30218 Rev. A
PRESSURE DROP CHARTS
Theplotsbelowdescribethemaximumpressuredropforeachmeterandeachowgroupthroughoutthe
meter’sallowableowrange.Todeterminepressuredrop:
1. Select the applicable meter size/chart.
2. Selecttheowgroupcurve(SNDmodelsonly)thatmatchestheapplication.
GROUP MATERIAL VISCOSITY
1 Up to 30 SSU (.20 to 1.00 Centipoise)
2 31 to 450 SSU (1 to 90 Centipoise)
3 450 to 1,000 SSU (90 to 220 Centipoise)
4 1,000 to 5,000 SSU (220 to 1,100 Centipoise)
5 5,500 to 20,000 SSU (1,100 to 4,400 Centipoise)
6 20,000 to 50,000 SSU (4,400 to 11,000 Centipoise)
3. Findthelocationonthecurvethatcorrespondstothemaximumowratefortheendapplication.
4. Themaximumpressuredropisidentiablefromtheverticalaxisonthechart.
Figure 4. Model SND Line Size B - 0.75” Bore
Group 5 Group 4 Group 3
Group 2
Group 1
Table des matières
Autres manuels Niagara Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur