NI NI-9157 Manuel utilisateur

NI-9157/9159
User Manual
and
Specifications
2022-07-01

Contents
NI 9157/9159 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
NI 9157/9159 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
ni.com
2
NI-9157/9159 User Manual and Specifications

NI 9157/9159 Overview
Figure 1. NI 9157/9159 Front Panel
4
6
2
5
1
C
C
V2
V1
INPUT
9-30 V
35W MAX
NO FPGA APP
USER FPGA1
USER FPGA2
USER FPGA3
P
USER FPGA1
USER FPGA2
USER FPGA3
POWER
USER FPGA1
USER FPGA2
USER FPGA3
LINK LINK
UPSTREAM
DOWNSTREAM
MXI-Express RIO
NI 915X
3
OFF
1. LEDs
2. Upstream Port
3. MXI-Express LINK LEDs
4. Downstream Port
5. Power Connector
6. DIP Switches
This document describes how to connect the NI 9157/9159 to a MXI-Express host
and one or more other chassis, and how to use the features of the NI 9157/9159. This
document also contains specifications for the NI 9157/9159.
Safety Guidelines
Caution Observe all instructions and cautions in the user documentation.
Using the product in a manner not specified can damage the product and
compromise the built-in safety protection.
© National Instruments 3
NI-9157/9159 User Manual and Specifications

Attention Suivez toutes les instructions et respectez toutes les mises
en garde de la documentation d'utilisation. L'utilisation du produit de
toute autre façon que celle spécifiée risque de l'endommager et de
compromettre la protection de sécurité intégrée.
Safety Guidelines for Hazardous Locations
The NI 9157/9159 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4
hazardous locations; Class I, Zone 2, AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous
locations; and nonhazardous locations only. Follow these guidelines if you are
installing the NI 9157/9159 in a potentially explosive environment. Not following
these guidelines may result in serious injury or death.
Caution Do not disconnect the power supply wires and connectors from
the controller unless power has been switched o.
Caution Do not disconnect I/O-side wires or connectors unless power has
been switched o or the area is known to be nonhazardous.
Caution Do not remove modules unless power has been switched o or
the area is known to be nonhazardous.
Caution Substitution of components may impair suitability for Class I,
Division 2, or Zone 2.
Caution The system must be installed in an enclosure certified for the
intended hazardous (classified) location, having a tool secured cover/door,
where a minimum protection of at least IP54 is provided.
ni.com
4
NI-9157/9159 User Manual and Specifications

Special Conditions for Hazardous Locations Use in Europe and
Internationally
The NI 9157/9159 has been evaluated as Ex nA IIC T4 Gc equipment under
DEMKO 07ATEX 0626664X and is IECEx UL 14.0089X certified. Each device is
marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient
temperatures of 0 °C ≤ Ta ≤ 55 °C.
Caution Transient protection shall be provided that is set at a level not
exceeding 140% of the peak rated voltage value of 85 V at the supply
terminals to the equipment.
Caution The system shall only be used in an area of not more than
Pollution Degree 2, as defined in IEC/EN 60664-1.
Caution The system shall be mounted in an ATEX/IECEx-certified
enclosure with a minimum ingress protection rating of at least IP54 as
defined in IEC/EN 60079-15.
Caution The enclosure must have a door or cover accessible only by the
use of a tool.
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and limits
for electromagnetic compatibility (EMC) stated in the product specifications. These
requirements and limits provide reasonable protection against harmful interference
when the product is operated in the intended operational electromagnetic
environment.
This product is intended for use in industrial locations. However, harmful
interference may occur in some installations, when the product is connected to
a peripheral device or test object, or if the product is used in residential or
© National Instruments 5
NI-9157/9159 User Manual and Specifications

commercial areas. To minimize interference with radio and television reception and
prevent unacceptable performance degradation, install and use this product in strict
accordance with the instructions in the product documentation.
Furthermore, any changes or modifications to the product not expressly approved
by National Instruments could void your authority to operate it under your local
regulatory rules.
Special Conditions for Marine Applications
Some products are approved for marine (shipboard) applications. To verify marine
approval certification for a product, visit ni.com/product-certifications, search by
model number, and click the appropriate link.
Notice In order to meet the EMC requirements for marine applications,
install the product in a shielded enclosure with shielded and/or filtered
power and input/output ports. In addition, take precautions when
designing, selecting, and installing measurement probes and cables to
ensure that the desired EMC performance is attained.
What You Need to Install the NI 9157/9159
■ NI 9157/9159 reconfigurable embedded chassis with integrated MXI-Express
(x1)
■One of the following MXI-Express (x1) host systems:
■PXI system with MXI-Express device installed
■PC with MXI-Express PCI or PCIe device installed
■NI Industrial Controller
Note
The NI 9157/9159 requires a host system with a PCI Express clock
that complies with the PCI Express Specification. The NI 9157/9159
may not be compatible with systems using noncompliant clocks,
particularly clocks with peak frequencies higher than 100 MHz. For
ni.com
6
NI-9157/9159 User Manual and Specifications

more information about PCI Express clock compatibility with the
NI 9157/9159, go to ni.com/info and enter the Info Code 915xclock.
■C Series I/O modules
■MXI-Express (x1) cable(s) up to 7 m long
■DIN rail mount kit (for DIN rail mounting only)
■ Panel mount kit (for panel mounting only)
■Three M4 or number 8 panhead screws (for mounting the chassis without
one of the listed mounting kits)
■Number 2 Phillips screwdriver
■Power supply
■ MXI-Express (x1) Series User Manual
Note Visit ni.com/info and enter the Info Code rdsowareversion to
determine which soware you need to use the NI 9157/9159.
Mounting the NI 9157/9159
You can mount the chassis horizontally on a 35 mm DIN rail or on a flat,
vertical, metallic surface such as a panel or wall. The maximum allowable ambient
temperature for operation is 55 °C. Mounting the chassis in a dierent orientation or
on a nonmetallic surface can reduce the maximum allowable ambient temperature
and can aect the typical accuracy of modules in the chassis. The following figure
shows the chassis mounted horizontally.
Figure 2. NI 9157/9159 Mounted Horizontally
Up
Measure the ambient temperature at each side of the chassis, 63.5 mm (2.5 in.) from
the side and 50.8 mm (2 in.) forward from the rear of the chassis.
© National Instruments 7
NI-9157/9159 User Manual and Specifications

Note For more information about typical accuracy specification for
modules, go to ni.com/info and enter the Info Code criotypical.
Caution Your installation must meet the following requirements for space
and cabling clearance:
■Allow 50.8 mm (2 in.) on the top and the bottom of the chassis for air
circulation.
■Allow 50.8 mm (2 in.) in front of modules for cabling clearance for
common connectors, such as the 10-terminal, detachable screw terminal
connector.
Figure 3. NI 9157/9159, Bottom View with Dimensions
63.5 mm
(2.50 in.)
50.8 mm
(2 in.) 406.3 mm
(16 in.)
50.8 mm
(2 in.)
48.4 mm
(1.91 in.)
1
1
89.4 mm
(3.52 in.)
63.5 mm
(2.50 in.)
29 mm
(1.14 in.)
Cabling Clearance
50.8 mm (2 in.)
1. Measure ambient temperature here.
Figure 4. NI 9157/9159, Front View with Dimensions
51.7 mm
(2.04 in.)
28.0 mm
(1.10 in.)
4.1 mm
(0.16 in.)
Cooling Outline
50.8 mm (2 in.)
88.1 mm
(3.47 in.)
Cooling Outline
50.8 mm (2 in.)
36.4 mm
(1.43 in.)
132.6 mm
(5.22 in.)
165.1 mm
(6.50 in.)
ni.com
8
NI-9157/9159 User Manual and Specifications

Figure 5. NI 9157/9159, Side View with Dimensions
18.7 mm
(0.74 in.)
44.1 mm
(1.74 in.)
69.5 mm
(2.74 in.)
51.4 mm
(2.02 in.)
68.2 mm
(2.68 in.)
The following sections contain instructions for the mounting methods. Before using
any of these mounting methods, record the serial number from the back of the
chassis. You will be unable to read the serial number aer you have mounted the
chassis.
Caution Make sure that no I/O modules are in the chassis before
mounting it.
Mounting the Chassis on a DIN Rail
Use the DIN rail mounting method if you already have a DIN rail configuration or if
you need to be able to remove the chassis quickly. You can order the NI 9916 DIN
rail mount kit if you want to mount the chassis on a DIN rail. You need one clip for
mounting the chassis on a standard 35 mm DIN rail. Complete the following steps to
mount the chassis on a DIN rail.
1. Fasten the DIN rail clip to the chassis using a number 2 Phillips screwdriver
and three M4 x 50 screws. NI provides these screws with the DIN rail mount kit.
Tighten the screws to a maximum torque of 1.3 N · m(11.5 lb · in.).
© National Instruments 9
NI-9157/9159 User Manual and Specifications

Figure 6. Installing the DIN Rail Clip on the NI 9157/9159
2. Insert one edge of the DIN rail into the deeper opening of the DIN rail clip.
Figure 7. One Edge of the DIN Rail Inserted in a Clip
3
2
1
1. DIN Rail Clip
2. DIN Rail
3. DIN Rail Spring
3. Press down firmly on the chassis to compress the spring until the clip locks in
place on the DIN rail.
Caution Make sure that no I/O modules are in the chassis before
removing it from the DIN rail.
ni.com
10
NI-9157/9159 User Manual and Specifications
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels NI Châssis

NI
NI PXI-1033 Manuel utilisateur

NI
NI cRIO-9082 Manuel utilisateur

NI
NI PXIe-1090 Manuel utilisateur

NI
NI PXI Express PXIe-1082 Manuel utilisateur

NI
NI PXIe-1083 Manuel utilisateur

NI
NI 9157 Manuel utilisateur

NI
NI PXIe-1082DC Manuel utilisateur

NI
NI NI-9154 Manuel utilisateur

NI
NI cRIO-9082 Manuel utilisateur

NI
NI PXI-1036 Manuel utilisateur