Response: 81B0000000000000000000 (Configuration success)
81B0010000000000000000 (Configuration failure)
(2)Read Configuration:
Downlink:02B0000000000000000000
Response:
82B0003C003C0000000000 (Current configuration)
Relay switch control
(3)Relay1, Relay 2, Relay3 normal open (disconnect)
Downlink:90B0070000000000000000 // bit0=relay1, bit1=relay2, bit2=relay3
(4)Relay1, Relay 2, Relay3 normal close (connect)
Downlink:91B0070000000000000000 // bit0=relay1, bit1=relay2, bit2=relay3
(5)Toggle relay normal open/close
Downlink:92B0070000000000000000 // bit0=relay1, bit1=relay2, bit2=relay3
Relay switch Type
Change relay switch type:
a. Toggle: Normal open/close type switch, ex. toggle switch
b. Momentary: Tact type switch, ex. tact switch
(6)Setting switch type is tact type switch
Downlink:03B0010000000000000000
Response:83B0000000000000000000 (Configuration success)
(7)Confirm switch type
Downlink:04B0000000000000000000
Response:84B0010000000000000000 (The switch type is tact type)