NetPing mini-UPS Manuel utilisateur

1. [Docs] NetPing mini-UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 [ENG] Netping mini-UPS, User guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1.1 [mini-UPS] Copyright and Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1.2 [mini-UPS] Installation and Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1.3 [mini-UPS] Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.1.4 [mini-UPS] Operating and Storage Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1.5 [mini-UPS] Review of a Mini-UPS Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1.6 [mini-UPS] Shipping Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.1.7 [mini-UPS] Sockets and Indication Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.1.8 [mini-UPS] Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[Docs] NetPing mini-UPS

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[ENG] Netping mini-UPS, User guide

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Copyright and Disclaimer
The information, contained in this document, can be changed by a manufacturer without a prior notice.Although every effort was made to make the
information in this document accurate and without errors, a manufacturer is not liable for their possible presence and for the consequences that may
result from the errors herein. A manufacturer is not liable if supplied equipment, software and this user guide does not correspond to expectations of a
user and his/her opinion about where and how to use all the above.All copyrights on supplied devices, described in this User Guide, as well as firmware
and software of devices and this User Guide belong to NetPing global Ltd. Сopying, replication and translation of this user guide to other
languagesare not allowed without a prior written permission of a rightholder. Copying, replication, changing, disassembling of provided software are
For the part of software that is provided in source codes, there is anot allowed without a prior written permission of a rightholder.
separate license agreement, which defines an order of its use and modification. Other trademarks used in this description belong to corresponding
rightholders.
Developer and manufacturer:
NetPing global Ltd

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Installation and Connection
NetPing mini-UPScanbeinstalledonahorizontaloraverticalsurface. A body of a device has holes for its mounting.
When mounting a device, there is a need to take into account the next restrictions:
Donotpoweradevicefromtwodifferentpowersupplyunitssimultaneouslyusinga socket DJK02 and terminals +DC/GND;
Avoid direct sunlight on a device;
Do not install a device near heat sources;
Donotconnectany equipment, whichcancauseoverload, toadevice’soutputs;
Do not open a body of a device;
Beforeatransportationoralong-termstorage, setaswitchBAT into theOFF position;
Keep a switch 5V – 12V in a5V position, if you do not plan to use a terminal 12V. This will increase a battery life.
Important!When switching to theOFF position, a device goes to a power supply standby mode. A device goes out of this mode only
after connecting a power supply. Switching to the ON position does not lead a device out of a standby mode. In a standby mode a
voltage is not fed to UPS outputs.

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Introduction
This user guide will help to become familiar with the peculiarities of a device operation as well as get an idea about its functionalityNetPing mini-UPS
and technical specifications, and prepare a device for operation.
A User Guide is designed for network administrators and users, who set up or operate a device. To work with a device properly, a user must have an
idea about the principles of building and functioning of local networks as well as possess the next knowledge and skills:
Basic knowledge in the area of local and global networks;
Basicknowledgeintheareaofarchitectureandprinciples of work of TCP/IP networks;
Basic knowledge in the area of architecture and principles of work of Ethernet networks.

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Operating and Storage Conditions
A device is designed for continuous round the clock operation indoors. In operating conditions of use, a device is resistant to an environment with
temperature in a range of 0°С - +40°С (32 – 104 degrees Fahrenheit) and relative humidity in a range of 5% - 95 % at 25°С (77 degrees Fahrenheit)
without moisture condensation. A device should be protected from direct moisture and direct sun light.
A construction of a device provides a reliable uninterrupted work during a long period of time without maintenance.Highly developed functionality of
remote setting and configuration of a device allows changing any parameters remotely and centrally for the most of the devices.
Devices should be stored in a temperature range between - 40°С and +70°С.
In rooms for keeping a device, a content of dust, acid and alkali gases, aggressive gases and other harmful impurities causing corrosion, should not
exceed a content of corrosion-active agents for atmosphere of type 1.
Important! A device must be connected to a power supply socket with a grounding contact or a hole, where a contact, located at an outlet
and connected to a ground wire, is inserted. Grounding must be performed according to the State Standard Р 50571.21-2000. An infraction
of this rule is aviolation of a device operation conditions and may be dangerous to human lives as well as damage other devices!

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Review of a Mini-UPS Device
Appearance of a device is shown on a picture:
Front panel of a device:
Back panel:

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
Characteristics of a Device Value
Voltage 12 V ... 48 V DC
Battery life of the deviceUniPing v3 2 hours
Battery life of the deviceUniPing server solution v3/SMS 4,5 hours
Weight 250 g
Shipping kit a device, an adapter cord
Power plug type DJK02 2.1 mm and a terminal
Temperature range 0 C ... 40 C° °
Dimensions of a device 75 x 95 x 40

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Shipping Kit
Into shipping kit are included:
A deviceNetPing mini-UPS;
Mating terminals– 4 pcs.;
Power cable.
Table des matières
Manuels UPS populaires d'autres marques

Pylontech
Pylontech Victron & Pylontech US5000 Manuel utilisateur